Qingguo Li

Prof. Qingguo Li


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2013 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
JZJun-Tian Zhang
Jun-Tian Zhang
ANAlison C Novak
Alison C Novak
BBBrenda Brouwer
Brenda Brouwer
QLQingguo Li
Qingguo Li
This study aims to validate a commercially available inertial sensor based motion capture system, Xsens MVN BIOMECH using its native protocols, against a camera-based motion capture system for the measurement of joint angular kinematics. Performance was evaluated by comparing waveform similarity using range of motion, mean error and a new formulation of the coefficient of multiple correlation (CMC). Three dimensional joint angles of the lower limbs were determined for ten healthy subjects while they performed three daily activities: level walking, stair ascent, and stair descent. Under all three walking conditions, the Xsens system most accurately determined the flexion/extension joint angle (CMC > 0.96) for all joints. The joint angle measurements associated with the other two joint axes had lower correlation including complex CMC values. The poor correlation in the other two joint axes is most likely due to differences in the anatomical frame definition of limb segments used by the Xsens and Optotrak systems. Implementation of a protocol to align these two systems is necessary when comparing joint angle waveforms measured by the Xsens and other motion capture systems.

10 May 2012 in Sensors
Verified
Journal Article
Open access
PDF file
SYShuozhi Yang
Shuozhi Yang
QLQingguo Li
Qingguo Li
Self-selected walking speed is an important measure of ambulation ability used in various clinical gait experiments. Inertial sensors, i.e., accelerometers and gyroscopes, have been gradually introduced to estimate walking speed. This research area has attracted a lot of attention for the past two decades, and the trend is continuing due to the improvement of performance and decrease in cost of the miniature inertial sensors. With the intention of understanding the state of the art of current development in this area, a systematic review on the exiting methods was done in the following electronic engines/databases: PubMed, ISI Web of Knowledge, SportDiscus and IEEE Xplore. Sixteen journal articles and papers in proceedings focusing on inertial sensor based walking speed estimation were fully reviewed. The existing methods were categorized by sensor specification, sensor attachment location, experimental design, and walking speed estimation algorithm.

1 May 2010 in Journal of Biomechanics
Verified
Journal Article
Closed access
QLQingguo Li
Qingguo Li
MYM. Young
M. Young
VNV. Naing
V. Naing
JDJ.M. Donelan
J.M. Donelan

23 June 2009 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
QLQingguo Li
Qingguo Li
VNVeronica Naing
Veronica Naing
JDJ Maxwell Donelan
J Maxwell Donelan
Biomechanical energy harvesting–generating electricity from people during daily activities–is a promising alternative to batteries for powering increasingly sophisticated portable devices. We recently developed a wearable knee-mounted energy harvesting device that generated electricity during human walking. In this methods-focused paper, we explain the physiological principles that guided our design process and present a detailed description of our device design with an emphasis on new analyses.

1 January 2013 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
ALAnnemarie Laudanski
Annemarie Laudanski
BBBrenda Brouwer
Brenda Brouwer
QLQingguo Li
Qingguo Li
This study validated the feasibility of inertial sensors in estimating lower limb joint kinematics during stair ambulation in healthy older adults and stroke survivors. Three dimensional motion data were collected using an inertial sensor‐based system from 9 persons with stroke and 9 healthy older adults as they ascended and descended a staircase at a self‐selected pace. The measured joint angles were compared with a laboratory‐based motion capture system by computing differences in range of motion (RoM), grand mean error, standard deviation, and coefficients of multiple correlations. For stroke survivors, differences in RoM measurements between these two systems were determined to be 3.3 ± 8.1°, while the highest correlations were found in the estimation of sagittal plane joint angles after offset correction. Results suggest that the inertial sensor system is suitable for estimating major joint angles in healthy older adults as well as the RoM for stroke survivors. New calibration procedures are necessary for applying the technology to a stroke population.

2 January 2015 in Medical Engineering & Physics
Verified
Journal Article
Closed access
ALAnnemarie Laudanski
Annemarie Laudanski
BBBrenda Brouwer
Brenda Brouwer
QLQingguo Li
Qingguo Li
Recent advances in the use of inertial measurement units (IMUs) for motion analysis suggest the possibility of using this technology for the monitoring of daily activities of individuals during rehabilitation post-stroke. Previous studies have utilized features extracted from accelerometer and gyroscope signals to develop classification models capable of identifying activities performed within large datasets. In this study, nine k-nearest neighbor cross-validated classifiers were developed using frequency-features derived from shank-mounted IMUs on the less-affected and affected limbs of subjects with stroke. These classifiers were evaluated for two separate datasets of post-stroke gait; the first a classification of three separate gait activities (overground walking, stair ascent, and stair descent), and the second a classification of five gait activities, overground walking, stair ascent, and descent with a distinction between stepping pattern used while negotiating stairs (step-over-step (SOS) and step-by-step (SBS)). The comparison showed the highest classification accuracy, 100% for the three-activities and 94% for the five-activities, was obtained using a classifier composed of features derived from accelerometer and gyroscope measurements from both IMUs on less-affected and affected limbs.