Yin Xu

Dr. Yin Xu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2016 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
YXYin Xu
Yin Xu
CLChen-Ching Liu
Chen-Ching Liu
KSKevin P. Schneider
Kevin P. Schneider
FTFrancis K. Tuffner
Francis K. Tuffner
DTDan T. Ton
Dan T. Ton
Microgrids can act as emergency sources to serve critical loads when utility power is unavailable. This paper proposes a resiliency-based methodology that uses microgrids to restore critical loads on distribution feeders after a major disaster. Due to limited capacity of distributed generators (DGs) within microgrids, dynamic performance of the DGs during the restoration process becomes essential. In this paper, the stability of microgrids, limits on frequency deviation, and limits on transient voltage and current of DGs are incorporated as constraints of the critical load restoration problem. The limits on the amount of generation resources within microgrids are also considered. By introducing the concepts of restoration tree and load group, restoration of critical loads is transformed into a maximum coverage problem, which is a linear integer program (LIP). The restoration paths and actions are determined for critical loads by solving the LIP. A 4-feeder, 1069-bus unbalanced test system with four microgrids is utilized to demonstrate the effectiveness of the proposed method. The method is applied to the distribution system in Pullman, WA, resulting in a strategy that uses generators on the Washington State University campus to restore service to the Hospital and City Hall in Pullman.

9 January 2019 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
YWYing Wang
Ying Wang
YXYin Xu
Yin Xu
JHJinghan He
Jinghan He
CLChen-Ching Liu
Chen-Ching Liu
KSKevin P. Schneider
Kevin P. Schneider
DTDan T. Ton
Dan T. Ton

10 October 2022 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
ASAleksandar M. Stanković
Aleksandar M. Stanković
KTKevin L. Tomsovic
Kevin L. Tomsovic
Fabrizio De CaroFabrizio De Caro
Fabrizio De Caro
MBMartin Braun
Martin Braun
JCJoe H. Chow
Joe H. Chow
SZShijia Zhao
Shijia Zhao
This paper summarizes the report prepared by an IEEE PES Task Force. Resilience is a fairly new technical concept for power systems, and it is important to precisely delineate this concept for actual applications. As a critical infrastructure, power systems have to be prepared to survive rare but extreme incidents (natural catastrophes, extreme weather events, physical/cyber-attacks, equipment failure cascades, etc.) to guarantee power supply to the electricity-dependent economy and society. Thus, resilience needs to be integrated into planning and operational assessment to design and operate adequately resilient power systems. Quantification of resilience as a key performance indicator is important, together with costs and reliability. Quantification can analyze existing power systems and identify resilience improvements in future power systems. Given that a 100% resilient system is not economic (or even technically achievable), the degree of resilience should be transparent and comprehensible. Several gaps are identified to indicate further needs for research and development.

29 April 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YWYing Wang
Ying Wang
YXYin Xu
Yin Xu
JLJiaxu Li
Jiaxu Li
JHJinghan He
Jinghan He
XWXiaojun Wang
Xiaojun Wang
Radiality constraints are involved in both distribution system restoration and reconfiguration problems. However, a set of widely used radiality constraints, i.e., the spanning tree (ST) constraints, has its limitations which have not been well recognized. In this letter, the limitation of the ST constraints is analyzed and an effective set of constraints, referred to as the single-commodity flow constraints, is presented. Furthermore, a combined set of constraints is proposed and case studies indicate that the combined constraints can gain computational efficiency in the reconfiguration problem. Recommendations on the use of radiality constraints are also provided.

7 February 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
ZWZhiwen Wang
Zhiwen Wang
CSChen Shen
Chen Shen
YXYin Xu
Yin Xu
FLFeng Liu
Feng Liu
XWXiangyu Wu
Xiangyu Wu
CLChen-Ching Liu
Chen-Ching Liu
Microgrids can be used to restore critical load after a natural disaster, enhancing resilience of a distribution network. To deal with the stochastic nature of intermittent energy resources, such as wind turbines (WTs) and photovoltaics (PVs), forecast information is usually required. However, some microgrids may not be equipped with power forecasting tools. To fill this gap, a risk-limiting strategy based on measurements is proposed. A Gaussian mixture model is used to represent a prior joint probability density function of power outputs of WTs and PVs over multiple periods. As time rolls forward, the probability distribution of WT/PV generation is recursively updated using the latest measurement data. The updated distribution is used as an input of the risk-limiting load restoration problem, enabling an equivalent transformation of the original chance constrained problem into a mixed integer linear programming. Simulations on a distribution system with three microgrids demonstrate the effectiveness of the proposed method. Results indicate that networked microgrids can perform better in uncertainty management relative to stand-alone microgrids.

25 August 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
YXYin Xu
Yin Xu
CLChen-Ching Liu
Chen-Ching Liu
ZWZhiwen Wang
Zhiwen Wang
KMKefei Mo
Kefei Mo
KSKevin P. Schneider
Kevin P. Schneider
DTDan T. Ton
Dan T. Ton
During a major outage in a secondary network distribution system, distributed generators (DGs) connected to the primary feeders as well as the secondary network can be used to serve critical loads. This paper proposed a resilience-oriented method to determine restoration strategies for secondary network distribution systems after a major disaster. Technical issues associated with the restoration process are analyzed, including the operation of network protectors, inrush currents caused by the energization of network transformers, synchronization of DGs to the network, and circulating currents among DGs. A look-ahead load restoration framework is proposed, incorporating technical issues associated with secondary networks, limits on DG capacity and generation resources, dynamic constraints, and operational limits. The entire outage duration is divided into a sequence of periods. Restoration strategies can be adjusted at the beginning of each period using the latest information. Numerical simulation of the modified IEEE 342-node low voltage networked test system is performed to validate the effectiveness of the proposed method.