The risk-based assessment is a new approach to the voltage stability assessment in power systems. Under several uncertainties, the security risk of static voltage stability with the consideration of wind power can be evaluated. In this paper, we first build a probabilistic forecast model for wind power generation based on real historical data. Furthermore, we propose a new probability voltage stability approach based on Conditional Value-at-Risk (CVaR) and Quasi-Monte Carlo (QMC) simulation. The QMC simulation is used to speed up Monte Carlo (MC) simulation by improving the sampling technique. Our CVaR-based model reveals critical characteristics of static voltage stability. The distribution of the local voltage stability margin, which considers the security risk at a forecast operating time interval, is estimated to evaluate the probability voltage stability. Tested on the modified IEEE New England 39-bus system and the IEEE 118-bus system, results from the proposal are compared against the result of the conventional proposal. The effectiveness and advantages of the proposed method are demonstrated by the test results.
Because the penetration level of renewable energy sources has increased rapidly in recent years, uncertainty in power system operation is gradually increasing. As an efficient tool for power system analysis under uncertainty, probabilistic power flow (PPF) is becoming increasingly important. The point-estimate method (PEM) is a well-known PPF algorithm. However, two significant defects limit the practical use of this method. One is that the PEM struggles to estimate high-order moments accurately; this defect makes it difficult for the PEM to describe the distribution of non-Gaussian output random variables (ORVs). The other is that the calculation burden is strongly related to the scale of input random variables (IRVs), which makes the PEM difficult to use in large-scale power systems. A novel approach based on principal component analysis (PCA) and high-dimensional model representation (HDMR) is proposed here to overcome the defects of the traditional PEM. PCA is applied to decrease the dimension scale of IRVs and eliminate correlations. HDMR is applied to estimate the moments of ORVs. Because HDMR considers the cooperative effects of IRVs, it has a significantly smaller estimation error for high-order moments in particular. Case studies show that the proposed method can achieve a better performance in terms of accuracy and efficiency than traditional PEM.
The traditional security-constrained optimal power flow (SCOPF) model under the classical N-1 criterion is implemented in the power industry to ensure the secure operation of a power system. However, with increasing uncertainties from renewable energy sources (RES) and loads, the existing SCOPF model has difficulty meeting the practical requirements of the industry. This paper proposed a novel chance-constrained preventive SCOPF model that considers the uncertainty of power injections, including RES and load, and contingency probability. The chance constraint is used to constrain the overall line flow within the limits with high probabilistic guarantees and to significantly reduce the constraint scales. The cumulant and Johnson systems were combined to accurately approximate the cumulative distribution functions, which is important in solving chance-constrained optimization problems. The simulation results show that the model proposed in this paper can achieve better performance than traditional SCOPF.
In this paper, a comprehensive real-time dispatch model considering renewable uncertainty based on dynamic load flow (DLF) is proposed. Through DLF, the primary and secondary frequency regulation amount caused by the variation of renewable energy as well as the line flow when primary and secondary regulation are deployed can be obtained easily. Not only the frequency constraints, but also the regular constraints like generator production limits and line flow limits are respected under both primary and secondary frequency regulation. To solve the dispatch problem with renewable uncertainty, chance-constrained programming based on cumulants and Cornish-fisher expansions (CCP-CMCF) is adopted to get the probability of holding the chance constraints and then the real-time dispatch model can be transformed into a quadratic programming. The simulation results show that the dispatch model proposed in this paper can deal with both primary and secondary regulation well and has a fast computation speed.
The number of electric vehicles (EVs) has rapidly grown over the last decade, and their charging loads have caused a significant impact on the cable capacity of the power system. The effect of the EV charging load on cables would be overestimated with harmonics and underestimated without harmonics. To accurately evaluate the impact of EV charging loads on the cable capacity of the distribution system, this paper presents a cable model considering the cable inductance and capacitance filtering effect and a methodology to solve the harmonic power flow in the distribution system. Then, the maximum penetration of EV under the constraint of system voltage and current and the maximum allowable temperature of cable insulation is calculated. An IEEE-33 node distribution system is adopted as an example. The total number of vehicles in the distribution system is assumed to be 2300. Results show that the LC filtering effect of cables can reduce the harmonic voltage and harmonic current above 29th by more than 99% when the penetration of EV is 20% and 6.6 kW single-phase uncontrolled rectifiers are used. The LC filtering effect of the cable can be disregarded when charging with Pulse-Width Modulation (PWM) rectifier chargers. The method improves the accuracy of cable capacity assessment by electric vehicle charging loads.
The rapidly growing demand of electric vehicle (EV) charging is one of the main challenges to modern electrical distribution systems. Accurate modelling of the EV charging load is crucial for charging load prediction and optimization. However, previous methods based on the charging behaviors of private EVs are hard to collect user’s private data. In this study, charging load data from 962 charging and battery swapping stations (CBSSs), classified into dedicated charging stations, public charging stations, and battery swapping stations, collected during 2021–2022, are analyzed to investigate seasonal variations in the charging coincidence factor. A data-driven probabilistic model of charging load, based on the Gaussian Mixture Model, is developed to address various scenarios, including new station construction, capacity expansions, and optimized charging strategies. This model is applicable to different types of CBSSs. A real-world 10 kV feeder system is employed as a case study to validate the model, and a delayed charging strategy is proposed. The results demonstrate that the proposed model accurately estimates charging load peaks after new construction and expansion in 2023, with an error rate under 3%. Furthermore, the delayed charging strategy achieved a 24.79% reduction in maximum load and a 31.96% decrease in the peak–valley difference. Its implementation in the real-world feeder significantly alleviated nighttime overloading in 2024.