Sheridan Mayo

Dr. Sheridan Mayo


Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2002 in Journal of Microscopy
Verified
Journal Article
Closed access
PDF file
DPD. Paganin
D. Paganin
SMSheridan Mayo
Sheridan Mayo
TGT. E. Gureyev
T. E. Gureyev
PMP. R. Miller
P. R. Miller
SWS. W. Wilkins
S. W. Wilkins

15 March 2011 in Nature Communications
Verified
Journal Article
Open access
PFPaolo Falcaro
Paolo Falcaro
AHAnita J. Hill
Anita J. Hill
KNKate M. Nairn
Kate M. Nairn
Jacek JasieniakJacek Jasieniak
Jacek Jasieniak
JMJames I. Mardel
James I. Mardel
DBDario Buso
Dario Buso
With controlled nanometre-sized pores and surface areas of thousands of square metres per gram, metal-organic frameworks (MOFs) may have an integral role in future catalysis, filtration and sensing applications. In general, for MOF-based device fabrication, well-organized or patterned MOF growth is required, and thus conventional synthetic routes are not suitable. Moreover, to expand their applicability, the introduction of additional functionality into MOFs is desirable. Here, we explore the use of nanostructured poly-hydrate zinc phosphate (α-hopeite) microparticles as nucleation seeds for MOFs that simultaneously address all these issues. Affording spatial control of nucleation and significantly accelerating MOF growth, these α-hopeite microparticles are found to act as nucleation agents both in solution and on solid surfaces. In addition, the introduction of functional nanoparticles (metallic, semiconducting, polymeric) into these nucleating seeds translates directly to the fabrication of functional MOFs suitable for molecular size-selective applications.

22 September 2003 in Optics Express
Verified
Journal Article
Open access
PDF file
SMSheridan Mayo
Sheridan Mayo
TDT.J. Davis
T.J. Davis
TGT.E. Gureyev
T.E. Gureyev
PMP.R. Miller
P.R. Miller
DPD. Paganin
D. Paganin
SWS.W. Wilkins
S.W. Wilkins
In-line phase contrast enables weakly absorbing specimens to be imaged successfully with x-rays, and greatly enhances the visibility of fine scale structure in more strongly absorbing specimens. This type of phase contrast requires a spatially coherent beam, a condition that can be met by a microfocus x-ray source. We have developed an x-ray microscope, based on such a source, which is capable of high resolution phase-contrast imaging and tomography. Phase retrieval enables quantitative information to be recovered from phase-contrast microscope images of homogeneous samples of known composition and density, and improves the quality of tomographic reconstructions.

24 May 2012 in Materials
Verified
Journal Article
Open access
PDF file
SMSheridan Mayo
Sheridan Mayo
ASAndrew Stevenson
Andrew Stevenson
SWStephen W. Wilkins
Stephen W. Wilkins
X-ray phase-contrast imaging and tomography make use of the refraction of X-rays by the sample in image formation. This provides considerable additional information in the image compared to conventional X-ray imaging methods, which rely solely on X-ray absorption by the sample. Phase-contrast imaging highlights edges and internal boundaries of a sample and is thus complementary to absorption contrast, which is more sensitive to the bulk of the sample. Phase-contrast can also be used to image low-density materials, which do not absorb X-rays sufficiently to form a conventional X-ray image. In the context of materials science, X-ray phase-contrast imaging and tomography have particular value in the 2D and 3D characterization of low-density materials, the detection of cracks and voids and the analysis of composites and multiphase materials where the different components have similar X-ray attenuation coefficients. Here we review the use of phase-contrast imaging and tomography for a wide variety of materials science characterization problems using both synchrotron and laboratory sources and further demonstrate the particular benefits of phase contrast in the laboratory setting with a series of case studies.

5 August 2002 in Journal of Microscopy
Verified
Journal Article
Closed access
PDF file
SMSheridan Mayo
Sheridan Mayo
PMP. R. Miller
P. R. Miller
SWS. W. Wilkins
S. W. Wilkins
TDT. J. Davis
T. J. Davis
DGD. Gao
D. Gao
ASA. W. Stevenson
A. W. Stevenson

6 March 2014 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Closed access
PDF file
SWS. W. Wilkins
S. W. Wilkins
YNYa. I. Nesterets
Ya. I. Nesterets
TGT. E. Gureyev
T. E. Gureyev
SMSheridan Mayo
Sheridan Mayo
APA. Pogany
A. Pogany
ASAndrew Stevenson
Andrew Stevenson
This review provides a brief overview, albeit from a somewhat personal perspective, of the evolution and key features of various hard X-ray phase-contrast imaging (PCI) methods of current interest in connection with translation to a wide range of imaging applications. Although such methods have already found wide-ranging applications using synchrotron sources, application to dynamic studies in a laboratory/clinical context, for example for in vivo imaging, has been slow due to the current limitations in the brilliance of compact laboratory sources and the availability of suitable high-performance X-ray detectors. On the theoretical side, promising new PCI methods are evolving which can record both components of the phase gradient in a single exposure and which can accept a relatively large spectral bandpass. In order to help to identify the most promising paths forward, we make some suggestions as to how the various PCI methods might be compared for performance with a particular view to identifying those which are the most efficient, given the fact that source performance is currently a key limiting factor on the improved performance and applicability of PCI systems, especially in the context of dynamic sample studies. The rapid ongoing development of both suitable improved sources and detectors gives strong encouragement to the view that hard X-ray PCI methods are poised for improved performance and an even wider range of applications in the near future.