Michael Busa

Dr. Michael Busa

University of Massachusetts Amherst, Amherst Center, Massachusetts, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2019 in International Journal of Behavioral Nutrition and Physical Activity
Verified
Journal Article
Open access
PDF file
CTCatrine Tudor-Locke
Catrine Tudor-Locke
EAElroy Aguiar
Elroy Aguiar
HHHo Han
Ho Han
SDScott Ducharme
Scott Ducharme
JSJohn Schuna
John Schuna
JSJohn Staudenmayer
John Staudenmayer
Previous studies have reported that walking cadence (steps/min) is associated with absolutely-defined intensity (metabolic equivalents; METs), such that cadence-based thresholds could serve as reasonable proxy values for ambulatory intensities. To establish definitive heuristic (i.e., evidence-based, practical, rounded) thresholds linking cadence with absolutely-defined moderate (3 METs) and vigorous (6 METs) intensity. In this laboratory-based cross-sectional study, 76 healthy adults (10 men and 10 women representing each 5-year age-group category between 21 and 40 years, BMI = 24.8 ± 3.4 kg/m2) performed a series of 5-min treadmill bouts separated by 2-min rests. Bouts began at 0.5 mph and increased in 0.5 mph increments until participants: 1) chose to run, 2) achieved 75% of their predicted maximum heart rate, or 3) reported a Borg rating of perceived exertion > 13. Cadence was hand-tallied, and intensity (METs) was measured using a portable indirect calorimeter. Optimal cadence thresholds for moderate and vigorous ambulatory intensities were identified using a segmented regression model with random coefficients, as well as Receiver Operating Characteristic (ROC) models. Positive predictive values (PPV) of candidate heuristic thresholds were assessed to determine final heuristic values. Optimal cadence thresholds for 3 METs and 6 METs were 102 and 129 steps/min, respectively, using the regression model, and 96 and 120 steps/min, respectively, using ROC models. Heuristic values were set at 100 steps/min (PPV of 91.4%), and 130 steps/min (PPV of 70.7%), respectively. Cadence thresholds of 100 and 130 steps/min can serve as reasonable heuristic thresholds representative of absolutely-defined moderate and vigorous ambulatory intensity, respectively, in 21–40 year olds. These values represent useful proxy values for recommending and modulating the intensity of ambulatory behavior and/or as measurement thresholds for processing accelerometer data. Clinicaltrials.gov ( NCT02650258 ).

1 April 2018 in Human Movement Science
Verified
Journal Article
Closed access
SDScott Ducharme
Scott Ducharme
JLJoshua Liddy
Joshua Liddy
JHJeffrey M. Haddad
Jeffrey M. Haddad
MBMichael Busa
Michael Busa
LCLaura J. Claxton
Laura J. Claxton
RERichard Van Emmerik
Richard Van Emmerik

4 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JCJohn Chase
John Chase
MBMichael Busa
Michael Busa
JSJohn W. Staudenmayer
John W. Staudenmayer
JSJohn R. Sirard
John R. Sirard
This study determined if using alternative sleep onset (SO) definitions impacted accelerometer-derived sleep estimates compared with polysomnography (PSG). Nineteen participants (48%F) completed a 48 h visit in a home simulation laboratory. Sleep characteristics were calculated from the second night by PSG and a wrist-worn ActiGraph GT3X+ (AG). Criterion sleep measures included PSG-derived Total Sleep Time (TST), Sleep Onset Latency (SOL), Wake After Sleep Onset (WASO), Sleep Efficiency (SE), and Efficiency Once Asleep (SE_ASLEEP). Analogous variables were derived from temporally aligned AG data using the Cole–Kripke algorithm. For PSG, SO was defined as the first score of ‘sleep’. For AG, SO was defined three ways: 1-, 5-, and 10-consecutive minutes of ‘sleep’. Agreement statistics and linear mixed effects regression models were used to analyze ‘Device’ and ‘Sleep Onset Rule’ main effects and interactions. Sleep–wake agreement and sensitivity for all AG methods were high (89.0–89.5% and 97.2%, respectively); specificity was low (23.6–25.1%). There were no significant interactions or main effects of ‘Sleep Onset Rule’ for any variable. The AG underestimated SOL (19.7 min) and WASO (6.5 min), and overestimated TST (26.2 min), SE (6.5%), and SE_ASLEEP (1.9%). Future research should focus on developing sleep–wake detection algorithms and incorporating biometric signals (e.g., heart rate).

7 February 2023 in Entropy
Verified
Journal Article
Open access
PDF file
JLJoshua Liddy
Joshua Liddy
MBMichael Busa
Michael Busa
The goal of this paper is to highlight considerations and provide recommendations for analytical issues that arise when applying entropy methods, specifically Sample Entropy (SampEn), to temporally correlated stochastic datasets, which are representative of a broad range of biomechanical and physiological variables. To simulate a variety of processes encountered in biomechanical applications, autoregressive fractionally integrated moving averaged (ARFIMA) models were used to produce temporally correlated data spanning the fractional Gaussian noise/fractional Brownian motion model. We then applied ARFIMA modeling and SampEn to the datasets to quantify the temporal correlations and regularity of the simulated datasets. We demonstrate the use of ARFIMA modeling for estimating temporal correlation properties and classifying stochastic datasets as stationary or nonstationary. We then leverage ARFIMA modeling to improve the effectiveness of data cleaning procedures and mitigate the influence of outliers on SampEn estimates. We also emphasize the limitations of SampEn to distinguish among stochastic datasets and suggest the use of complementary measures to better characterize the dynamics of biomechanical variables. Finally, we demonstrate that parameter normalization is not an effective procedure for increasing the interoperability of SampEn estimates, at least not for entirely stochastic datasets.

1 November 2019 in Value in Health
Verified
Journal Article
Closed access
MBMichael Busa
Michael Busa
TPThomas Günther Pomorski
Thomas Günther Pomorski
KMK. Mazzag
K. Mazzag
MVM. Vizsy
M. Vizsy
IBI. Boncz
I. Boncz
BMBalint Molics
Balint Molics

18 July 2025 in Psychophysiology
Verified
Journal Article
Open access
NNNader Naghavi
Nader Naghavi
TCThomas Cook
Thomas Cook
RTRyan Turner
Ryan Turner
SSSofiya Shreyer
Sofiya Shreyer
KCKatherine Colfer
Katherine Colfer
MBMichael Busa
Michael Busa
During menopause, the majority of women experience hot flashes (HF) that have a significant negative impact on sleep and quality of life. Current HF therapies are either ineffective or associated with unacceptable side effects. Digital health technologies offer a novel opportunity to fill this treatment gap with just‐in‐time thermal interventions through wearable devices. Thermal interventions have shown promise in reducing the negative impact of HFs. We hypothesized that HF event onsets can be accurately and reliably predicted from physiological signals prior to a person's perception of the events. This study investigated the feasibility of using skin conductance (SC) to predict the onset of HF events before they are subjectively perceived. 62 women who were experiencing HFs and self‐reported being in peri‐ or postmenopause were recruited. Data collection consisted of three remotely conducted 48‐h sessions. During each session, SC from the lateral torso was measured continuously and participants logged the precise timing of each perceived HF event onset. We developed new features to identify characteristics of SC signals before HFs were perceived. The best performing model trained with these features identified 82% of HF events on average 17 s before the onset with less than 2% false‐positive rate. Among the identified events, the model predicted 69% of HF events before onset. This study demonstrates the feasibility of predicting HF event onsets before subjective perception. Future studies should investigate both multimodal prediction as well as user acceptance and effectiveness of just‐in‐time thermal interventions.