Michael Grams

Dr. Michael Grams


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Practical Radiation Oncology
Verified
Journal Article
Open access
MGMichael Grams
Michael Grams
DODawn Owen
Dawn Owen
SPSean S. Park
Sean S. Park
IPIvy A. Petersen
Ivy A. Petersen
MHMichael G. Haddock
Michael G. Haddock
DMDaniel J. Ma
Daniel J. Ma
To describe a novel and practical volumetric modulated arc therapy (VMAT) planning approach for grid therapy. Dose is prescribed to 1.5 cm diameter spherical contours placed throughout the gross tumor volume (GTV). Placement of spheres is variable, but they must maintain at least a 3 cm (center to center) separation and the edge of any sphere must be at least 1 cm from any organ at risk (OAR). Three concentric ring structures are used during optimization to confine the highest doses to the center of the spheres and maximize dose sparing between them. The end result is alternating regions of high and low dose throughout the GTV and minimal dose to OARs. High intensity flattening filter free (FFF) modes are used to efficiently deliver the plans and entire treatments typically take only 15 to 20 minutes. The approach is illustrated with two examples treated at our institution. Patient #1 had a 1703 cubic centimeter (cc) mediastinal mass and was prescribed 20 Gray (Gy) to 24 spherical regions within the GTV. Patient #2 had a 3680 cc abdominal tumor and was prescribed 18 Gy to 32 spherical regions within the GTV. Both patients received additional consolidative radiation approximately 1 week after the initial VMAT grid treatment. Each patient experienced marked reduction in tumor size and symptomatic relief without treatment related complications. We have described in detail a planning approach for VMAT grid therapy treatments which can typically be delivered in a clinically practical time span. The VMAT approach is especially useful for tumors which are surrounded by sensitive critical structures. As many centers currently offer VMAT treatments, the approach is widely accessible and can be readily implemented once appropriate patient selection and delivery processes are established.

11 July 2024 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Open access
MGMichael Grams
Michael Grams
CMChrystian Quintero Mateus
Chrystian Quintero Mateus
MMMaryam Mashayekhi
Maryam Mashayekhi
RMRobert W. Mutter
Robert W. Mutter
VDValentin Djonov
Valentin Djonov
SLScott C. Lester
Scott C. Lester
Minibeam radiation therapy (MBRT) is characterized by the delivery of submillimeter wide regions of high "peak" and low "valley" doses throughout a tumor. Preclinical studies have long shown the promise of this technique, and we report here the first clinical implementation of MBRT. A clinical orthovoltage unit was commissioned for MBRT patient treatments using 3, 4, 5, 8, and 10 cm diameter cones. The 180 kVp output was spatially separated into minibeams using a tungsten collimator with 0.5 mm wide slits spaced 1.1 mm on center. Percentage depth dose (PDD) measurements were obtained using film dosimetry and plastic water for both peak and valley doses. PDDs were measured on central axis for offsets of 0, 0.5, and 1 cm. The peak-to-valley ratio (PVR) was calculated at each depth for all cones and offsets. To mitigate the effects of patient motion on delivered dose, patient-specific 3D printed collimator holders were created. These conformed to the unique anatomy of each patient and affixed the tungsten collimator directly to the body. Two patients were treated with MBRT, both received 2 fractions. Peak PDDs decreased gradually with depth. Valley PDDs initially increased slightly with depth, then decreased gradually beyond 2 cm. PVRs were highest at the surface for smaller cone sizes and offsets. In vivo film dosimetry confirmed a distinct delineation of peak and valley doses on both patients treated with MBRT with no dose blurring. Both patients experienced prompt improvement in symptoms and tumor response. We report commissioning results, treatment processes, and the first two patients treated with MBRT using a clinical orthovoltage unit. While demonstrating feasibility of this approach is a crucial first step toward wider translation, clinical trials are needed to further establish safety and efficacy.

10 June 2023 in Physica Medica
Verified
Journal Article
Closed access
MGMichael Grams
Michael Grams
CDChristopher L. Deufel
Christopher L. Deufel
JKJames A. Kavanaugh
James A. Kavanaugh
KCKimberly S. Corbin
Kimberly S. Corbin
SASafia K. Ahmed
Safia K. Ahmed
DODawn Owen
Dawn Owen

10 April 2022 in Practical Radiation Oncology
Verified
Journal Article
Closed access
MGMichael Grams
Michael Grams
HTHok Seum Wan Chan Tseung
Hok Seum Wan Chan Tseung
SIShima Ito
Shima Ito
YZYan Zhang
Yan Zhang
DODawn Owen
Dawn Owen
DMDaniel J. Ma
Daniel J. Ma

18 February 2022 in Cancers
Verified
Journal Article
Open access
PDF file
Hualin ZhangHualin Zhang
Hualin Zhang
MGMichael Grams
Michael Grams
JFJoseph James Foy
Joseph James Foy
NMNina A. Mayr
Nina A. Mayr
Computations of heterogeneity dose parameters in GRID therapy remain challenging in many treatment planning systems (TPS). To address this difficulty, we developed reference dose tables for a standard GRID collimator and validate their accuracy. The .decimal Inc. GRID collimator was implemented within the Eclipse TPS. The accuracy of the dose calculation was confirmed in the commissioning process. Representative sets of simulated ellipsoidal tumours ranging from 6–20 cm in diameter at a 3-cm depth; 16-cm ellipsoidal tumours at 3, 6, and 10 cm in depth were studied. All were treated with 6MV photons to a 20 Gy prescription dose at the tumour center. From these, the GRID therapy dosimetric parameters (previously recommended by the Radiosurgery Society white paper) were derived. Differences in D5 through D95 and EUD between different tumour sizes at the same depth were within 5% of the prescription dose. PVDR from profile measurements at the tumour center differed from D10/D90, but D10/D90 variations for the same tumour depths were within 11%. Three approximation equations were developed for calculating EUDs of different prescription doses for three radiosensitivity levels for 3-cm deep tumours. Dosimetric parameters were consistent and predictable across tumour sizes and depths. Our study results support the use of the developed tables as a reference tool for GRID therapy.

15 March 2025 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
DGDarwin Abraham Garcia
Darwin Abraham Garcia
JFJennifer M. Fazzari
Jennifer M. Fazzari
RHRuslan Hlushchuk
Ruslan Hlushchuk
OKOleksiy-Zakhar Khoma
Oleksiy-Zakhar Khoma
KBKatrina K. Bakken
Katrina K. Bakken
MGMichael Grams
Michael Grams