Vertical axis wind turbines have always been a controversial technology; claims regarding their benefits and drawbacks have been debated since the initial patent in 1931. Despite this contention, very little systematic vertical axis wind turbine research has been accomplished. Experimental assessments remain prohibitively expensive, while analytical analyses are limited by the complexity of the system. Numerical methods can address both concerns, but inadequate computing power hampered this field. Instead, approximating models were developed which provided some basis for study; but all these exhibited high error margins when compared with actual turbine performance data and were only useful in some operating regimes. Modern computers are capable of more accurate computational fluid dynamics analysis, but most research has focused on horizontal axis configurations or modeling of single blades rather than full geometries. In order to address this research gap, a systematic review of vertical axis wind-power turbine (VAWT) was undertaken, starting with establishment of a methodology for vertical axis wind turbine simulation that is presented in this paper. Replicating the experimental prototype, both 2D and 3D models of a three-bladed vertical axis wind turbine were generated. Full transient computational fluid dynamics (CFD) simulations using mesh deformation capability available in ansys-CFX were run from turbine start-up to operating speed and compared with the experimental data in order to validate the technique. A circular inner domain, containing the blades and the rotor, was allowed to undergo mesh deformation with a rotational velocity that varied with torque generated by the incoming wind. Results have demonstrated that a transient CFD simulation using a two-dimensional computational model can accurately predict vertical axis wind turbine operating speed within 12% error, with the caveat that intermediate turbine performance is not accurately captured.
Mechanical circulatory support options for infants and children are very limited in the United States. Existing circulatory support systems have proven successful for short-term pediatric assist, but are not completely successful as a bridge-to-transplant or bridge-to-recovery. To address this substantial need for alternative pediatric mechanical assist, we are developing a novel, magnetically levitated, axial flow pediatric ventricular assist device (PVAD) intended for longer-term ventricular support. Three major numerical design and optimization phases have been completed. A prototype was built based on the latest numerical design (PVAD3) and hydraulically tested in a flow loop. The plastic PVAD prototype delivered 0.5-4 lpm, generating pressure rises of 50-115 mm Hg for operating speeds of 6,000-9,000 rpm. The experimental testing data and the numerical predictions correlated well. The error between these sets of data was found to be generally 7.8% with a maximum deviation of 24% at higher flow rates. The axial fluid forces for the numerical simulations ranged from 0.5 to 1 N and deviated from the experimental results by generally 8.5% with a maximum deviation of 12% at higher flow rates. These hydraulic results demonstrate the excellent performance of the PVAD3 and illustrate the achievement of the design objectives.
21 November 2012 in Journal of Engineering for Gas Turbines and Power
Traditional annular seal models are based on bulk flow theory. While these methods are computationally efficient and can predict dynamic properties fairly well for short seals, they lack accuracy in cases of seals with complex geometry or with large aspect ratios (above 1.0). In this paper, the linearized rotordynamic coefficients for a seal with a large aspect ratio are calculated by means of a three-dimensional CFD analysis performed to predict the fluid-induced forces acting on the rotor. For comparison, the dynamic coefficients were also calculated using two other codes: one developed on the bulk flow method and one based on finite difference method. These two sets of dynamic coefficients were compared with those obtained from CFD. Results show a reasonable correlation for the direct stiffness estimates, with largest value predicted by CFD. In terms of cross-coupled stiffness, which is known to be directly related to cross-coupled forces that contribute to rotor instability, the CFD also predicts the highest value; however, a much larger discrepancy can be observed for this term (73% higher than the value predicted by the finite difference method and 79% higher than the bulk flow code prediction). One can see similar large differences in predictions in the estimates for damping and direct mass coefficients, where the highest values are predicted by the bulk flow method. These large variations in damping and mass coefficients, and most importantly the large difference in the cross-coupled stiffness predictions, may be attributed to the large difference in seal geometry (i.e., the large aspect ratio AR > 1.0 of this seal model versus the short seal configuration the bulk flow code is usually calibrated for using an empirical friction factor).
Thousands of cardiac failure patients per year in the United States could benefit from long-term mechanical circulatory support as destination therapy. To provide an improvement over currently available devices, we have designed a fully implantable axial-flow ventricular assist device with a magnetically levitated impeller (LEV-VAD). In contrast to currently available devices, the LEV-VAD has an unobstructed blood flow path and no secondary flow regions, generating substantially less retrograde and stagnant flow. The pump design included the extensive use of conventional pump design equations and computational fluid dynamics (CFD) modeling for predicting pressure-flow curves, hydraulic efficiencies, scalar fluid stress levels, exposure times to such stress, and axial fluid forces exerted on the impeller for the suspension design. Flow performance testing was completed on a plastic prototype of the LEV-VAD for comparison with the CFD predictions. Animal fit trials were completed to determine optimum pump location and cannulae configuration for future acute and long-term animal implantations, providing additional insight into the LEV-VAD configuration and implantability. Per the CFD results, the LEV-VAD produces 6 l/min and 100 mm Hg at a rotational speed of approximately 6300 rpm for steady flow conditions. The pressure-flow performance predictions demonstrated the VAD’s ability to deliver adequate flow over physiologic pressures for reasonable rotational speeds with best efficiency points ranging from 25% to 30%. The CFD numerical estimations generally agree within 10% of the experimental measurements over the entire range of rotational speeds tested. Animal fit trials revealed that the LEV-VAD’s size and configuration were adequate, requiring no alterations to cannulae configurations for future animal testing. These acceptable performance results for LEV-VAD design support proceeding with manufacturing of a prototype for extensive mock loop and initial acute animal testing.
A ventricular assist device (VAD), which is a miniaturized axial flow pump from the point of view of mechanism, has been designed and studied in this report. It consists of an inducer, an impeller, and a diffuser. The main design objective of this VAD is to produce an axial pump with a streamlined, idealized, and nonobstructing blood flow path. The magnetic bearings are adapted so that the impeller is completely magnetically levitated. The VAD operates under transient conditions because of the spinning movement of the impeller and the pulsatile inlet flow rate. The design method, procedure, and iterations are presented. The VAD's performance under transient conditions is investigated by means of computational fluid dynamics (CFD). Two reference frames, rotational and stationary, are implemented in the CFD simulations. The inlet and outlet surfaces of the impeller, which are connected to the inducer and diffuser respectively, are allowed to rotate and slide during the calculation to simulate the realistic spinning motion of the impeller. The flow head curves are determined, and the variation of pressure distribution during a cardiac cycle (including systole and diastole) is given. The axial oscillation of impeller is also estimated for the magnetic bearing design. The transient CFD simulation, which requires more computer resources and calculation efforts than the steady simulation, provides a range rather than only a point for the VAD's performance. Because of pulsatile flow phenomena and virtual spinning movement of the impeller, the transient simulation, which is realistically correlated with the in vivo implant scenarios of a VAD, is essential to ensure an effective and reliable VAD design.