Eun-Taek Han

Dr. Eun-Taek Han


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2010 in Journal of Proteome Research
Verified
Journal Article
Closed access
JCJun-Hu Chen
Jun-Hu Chen
JJJae-Wan Jung
Jae-Wan Jung
YWYue Wang
Yue Wang
KHKwon-Soo Ha
Kwon-Soo Ha
FLFeng Lu
Feng Lu
EHEun-Taek Han
Eun-Taek Han

21 June 2011 in Parasites & Vectors
Verified
Journal Article
Open access
PDF file
ZTZhi-Yong Tao
Zhi-Yong Tao
HZHua-Yun Zhou
Hua-Yun Zhou
HXHui Xia
Hui Xia
SXSui Xu
Sui Xu
HZHan-Wu Zhu
Han-Wu Zhu
QGQi Gao
Qi Gao
Background: Loop-mediated isothermal amplification (LAMP) is a high performance method for detecting DNA and holds promise for use in the molecular detection of infectious pathogens, including Plasmodium spp. However, in most malaria-endemic areas, which are often resource-limited, current LAMP methods are not feasible for diagnosis due to difficulties in accurately interpreting results with problems of sensitive visualization of amplified products, and the risk of contamination resulting from the high quantity of amplified DNA produced. In this study, we establish a novel visualized LAMP method in a closed-tube system, and validate it for the diagnosis of malaria under simulated field conditions. Methods: A visualized LAMP method was established by the addition of a microcrystalline wax-dye capsule containing the highly sensitive DNA fluorescence dye SYBR Green I to a normal LAMP reaction prior to the initiation of the reaction. A total of 89 blood samples were collected on filter paper and processed using a simple boiling method for DNA extraction, and then tested by the visualized LAMP method for Plasmodium vivax infection. Results: The wax capsule remained intact during isothermal amplification, and released the DNA dye to the reaction mixture only when the temperature was raised to the melting point following amplification. Soon after cooling down, the solidified wax sealed the reaction mix at the bottom of the tube, thus minimizing the risk of aerosol contamination. Compared to microscopy, the sensitivity and specificity of LAMP were 98.3% (95% confidence interval (CI): 91.1-99.7%) and 100% (95% CI: 88.3-100%), and were in close agreement with a nested polymerase chain reaction method. Conclusions: This novel, cheap and quick visualized LAMP method is feasible for malaria diagnosis in resource-limited field settings.

1 June 2014 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
PDF file
BWBo Wang
Bo Wang
SHSoe-Soe Han
Soe-Soe Han
CCCho Cho
Cho Cho
Jin Hee HanJin Hee Han
Jin Hee Han
YCYang Cheng
Yang Cheng
EHEun-Taek Han
Eun-Taek Han
Asymptomatic infection is an important obstacle for controlling disease in countries where malaria is endemic. Because asymptomatic carriers do not seek treatment for their infections, they can have high levels of gametocytes and constitute a reservoir available for new infection. We employed a sample pooling/PCR-based molecular detection strategy for screening malaria infection in residents from areas of Myanmar where malaria is endemic. Blood samples ( n = 1,552) were collected from residents in three areas of malaria endemicity (Kayin State, Bago, and Tanintharyi regions) of Myanmar. Two nested PCR and real-time PCR assays showed that asymptomatic infection was detected in about 1.0% to 9.4% of residents from the surveyed areas. The sensitivities of the two nested PCR and real-time PCR techniques were higher than that of microscopy examination (sensitivity, 100% versus 26.4%; kappa values, 0.2 to 0.5). Among the three regions, parasite-positive samples were highly detected in subjects from the Bago and Tanintharyi regions. Active surveillance of residents from regions of intense malaria transmission would reduce the risk of morbidity and mitigate transmission to the population in these areas of endemicity. Our data demonstrate that PCR-based molecular techniques are more efficient than microscopy for nationwide surveillance of malaria in countries where malaria is endemic.

1 March 2013 in Expert Review of Molecular Diagnostics
Verified
Journal Article
Closed access
EHEun-Taek Han
Eun-Taek Han
Malaria is one of the most important infectious tropical diseases. Rapid and accurate diagnostics are the basis of therapeutic care for most febrile patients in field clinics and health centers where novel molecular techniques have overcome sensitivity and specificity limitations. Loop-mediated isothermal amplification (LAMP) is a novel molecular method for rapid DNA target amplification with high specificity in isothermal conditions. LAMP provides a simple and rapid diagnostic tool for the early detection and species-specific identification of Plasmodium parasites using the read-out of the LAMP with the naked eye in the field, with no requirement for expensive thermal cyclers. LAMP is readily applicable to clinical diagnosis and active surveillance of malaria parasites in reference laboratories and research centers of endemic countries as a new alternative molecular diagnostic solution. This article summarizes current technical developments, applications, limitations and the future prospects for malaria diagnosis using LAMP in developed countries and endemic areas.

1 May 2014 in Journal of Proteomics
Verified
Journal Article
Closed access
FLFeng Lu
Feng Lu
JLJian Li
Jian Li
BWBo Wang
Bo Wang
YCYang Cheng
Yang Cheng
DKDeok-Hoon Kong
Deok-Hoon Kong
EHEun-Taek Han
Eun-Taek Han

13 September 2008 in Parasitology Research
Verified
Journal Article
Closed access
PDF file
JCJun-Hu Chen
Jun-Hu Chen
CKChang Won Kang
Chang Won Kang
ESEun-Hwa Sohn
Eun-Hwa Sohn
YCYong-Soon Choi
Yong-Soon Choi
EHEun-Taek Han
Eun-Taek Han