Noemi Cucurachi

Dr. Noemi Cucurachi

University of Padua, Padua, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2022 in Current Oncology
Verified
Journal Article
Open access
PDF file
MBMarco Bertolini
Marco Bertolini
VTValeria Trojani
Valeria Trojani
ABAndrea Botti
Andrea Botti
NCNoemi Cucurachi
Noemi Cucurachi
MGMarco Galaverni
Marco Galaverni
PCPatrizia Ciammella
Patrizia Ciammella
The purpose of this multi-centric work was to investigate the relationship between radiomic features extracted from pre-treatment computed tomography (CT), positron emission tomography (PET) imaging, and clinical outcomes for stereotactic body radiation therapy (SBRT) in early-stage non-small cell lung cancer (NSCLC). One-hundred and seventeen patients who received SBRT for early-stage NSCLC were retrospectively identified from seven Italian centers. The tumor was identified on pre-treatment free-breathing CT and PET images, from which we extracted 3004 quantitative radiomic features. The primary outcome was 24-month progression-free-survival (PFS) based on cancer recurrence (local/non-local) following SBRT. A harmonization technique was proposed for CT features considering lesion and contralateral healthy lung tissues using the LASSO algorithm as a feature selector. Models with harmonized CT features (B models) demonstrated better performances compared to the ones using only original CT features (C models). A linear support vector machine (SVM) with harmonized CT and PET features (A1 model) showed an area under the curve (AUC) of 0.77 (0.63–0.85) for predicting the primary outcome in an external validation cohort. The addition of clinical features did not enhance the model performance. This study provided the basis for validating our novel CT data harmonization strategy, involving delta radiomics. The harmonized radiomic models demonstrated the capability to properly predict patient prognosis.

23 May 2023 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
MIMauro Iori
Mauro Iori
EGElisa Grassi
Elisa Grassi
LPLorenzo Piergallini
Lorenzo Piergallini
GMGreta Meglioli
Greta Meglioli
ABAndrea Botti
Andrea Botti
FFFederica Fioroni
Federica Fioroni
Background: 18F-FDG PET/CT imaging allows to study oncological patients and their relative diagnosis through the standardised uptake value (SUV) evaluation. During radiopharmaceutical injection, an extravasation event may occur, making the SUV value less accurate and possibly leading to severe tissue damage. The study aimed to propose a new technique to monitor and manage these events, to provide an early evaluation and correction to the estimated SUV value through a SUV correction coefficient. Methods: A cohort of 70 patients undergoing 18F- FDG PET/CT examinations was enrolled. Two portable detectors were secured on the patients' arms. The dose-rate (DR) time curves on the injected DRin and contralateral DRcon arm were acquired during the first 10 min of injection. Such data were processed to calculate the parameters ΔpinNOR = (DRinmax- DRinmean)/DRinmax and ΔRt = (DRin(t) − DRcon(t)), where DRinmax is the maximum DR value, DRinmean is the average DR value in the injected arm. OLINDA software allowed dosimetric estimation of the dose in the extravasation region. The estimated residual activity in the extravasation site allowed the evaluation of the SUV's correction value and to define an SUV correction coefficient. Results: Four cases of extravasations were identified for which ΔRt [(390 ± 26) µSv/h], while ΔRt [(150 ± 22) µSv/h] for abnormal and ΔRt [(24 ± 11) µSv/h] for normal cases. The ΔpinNOR showed an average value of (0.44 ± 0.05) for extravasation cases and an average value of (0.91 ± 0.06) and (0.77 ± 0.23) in normal and abnormal classes, respectively. The percentage of SUV reduction (SUV%CR) ranges between 0.3% and 6%. The calculated self-tissue dose values range from 0.027 to 0.573 Gy, according to the segmentation modality. A similar correlation between the inverse of ΔpinNOR and the normalised ΔRt with the SUV correction coefficient was found. Conclusions: The proposed metrics allowed to characterised the extravasation events in the first few minutes after the injection, providing an early SUV correction when necessary. We also assume that the characterisation of the DR-time curve of the injection arm is sufficient for the detection of extravasation events. Further validation of these hypotheses and key metrics is recommended in larger cohorts.

8 January 2025 in Physica Medica
Verified
Journal Article
Closed access
RSRoberto Sghedoni
Roberto Sghedoni
DODaniela Origgi
Daniela Origgi
NCNoemi Cucurachi
Noemi Cucurachi
GMGiuseppe Castiglioni Minischetti
Giuseppe Castiglioni Minischetti
DADavide Alio
Davide Alio
LBLuca Boldrini
Luca Boldrini

8 September 2022 in Research Square
Verified
Preprint
Open access
PDF file
MIMauro Iori
Mauro Iori
EGElisa Grassi
Elisa Grassi
PLPiergallini Lorenzo
Piergallini Lorenzo
GMGreta Meglioli
Greta Meglioli
ABAndrea Botti
Andrea Botti
FFFederica Fioroni
Federica Fioroni
Background18F-FDG PET/CT imaging allows to study oncological patients and their relative diagnosis through the Standardized Uptake Value (SUV) evaluation. During radiopharmaceutical injection, an extravasation event may occur, making the SUV value less accurate and possibly leading to severe tissue damage. The aim of the study was to propose a new technique to monitor and manage these events, in order to evaluate a correction to the calculated SUV value. Methods A cohort of 70 patients undergoing18F- FDG PET/CT exams was enrolled. Two portable detectors were secured on the patients' arms. The dose-rate (DR) time curves on the injected DRinand contralateral DRconarm were acquired during the first 10 minutes of injection. Such data were processed to calculate the parameters ΔpinNOR= (DRinmax- DRinmean)/ DRinmaxand ΔRt= (DRin(t) - DRcon(t)), where DRinmaxis the maximum DR value, DRinmeanis the average DR value in the injected arm. OLINDA software allowed dosimetric estimation of the dose in the extravasation region. The estimated residual activity in the extravasation site allowed the evaluation of the SUV's correction value and to define an SUV correction coefficient. Results Four cases of extravasations were identified for which ΔRt[(390 ± 26) µSv/h], while ΔRt[(150 ± 22) µSv/h] for abnormal and ΔRt[(24 ± 11) µSv/h] for normal cases. The ΔpinNORshowed an average value of 0.44 for extravasation cases and an average value of (0.91 ± 0.06) and (0.77 ± 0.23) in normal and abnormal classes, respectively. The percentage of SUV reduction (SUV%CR) ranges between 0.3% and 6%. The calculated self-tissue dose values range from 0.027 Gy to 0.573 Gy, according to the segmentation modality. A similar correlation between the inverse of ΔpinNORand the normalised ΔRtwith the SUV correction coefficient was found. Conclusions The proposed metrics allowed to characterised the extravasation events in the first few minutes after the injection, providing an SUV correction when necessary. We also assume that the characterization of the DR-time curve of the injection arm is sufficient for the detection of extravasation events. Further validation of these hypotheses and key metrics is recommended in larger cohorts.