Eduardo M. Sosa

Prof. Dr. Eduardo M. Sosa


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2014 in Friction
Verified
Journal Article
Open access
PDF file
ESEduardo M. Sosa
Eduardo M. Sosa
GTGregory J. Thompson
Gregory J. Thompson
EBEver J. Barbero
Ever J. Barbero
SGSubhadeep Ghosh
Subhadeep Ghosh
KPKevin L. Peil
Kevin L. Peil
The availability of high-strength fabrics and progress in the development of large-scale inflatable technology made possible the creation of temporary and quickly deployable structures for protection of underground infrastructure. Inflatable structures are relatively lightweight and portable, and can maintain the required rigidity while in operation. These benefits have prompted the development of inflatable structures for use in confined spaces, such as tunnels and large-diameter pipes to act as barriers for containing flooding with minimal infrastructure modification. This work presents experimental results obtained from the evaluation of frictional characteristics of the fabric material that constitute the structural membrane of confined inflatable structures developed for protection of underground transportation tunnels and other large conduits. Friction tests at coupon level and slippage tests in a reduced-scale inflatable structure were performed in order to evaluate the frictional characteristics of Vectran webbings. Tests at coupon level were performed to determine the friction coefficient for different surface types and conditions. Tests with the reduced-scale inflatable structure contributed to the understanding of the friction characteristics at system level when subjected to different pressurization or depressurization sequences designed to induce slippage. Test results indicate that friction coefficient values at coupon level are about 29 percent higher than values derived from reduced-scale tests.

1 November 2021 in Applied Ergonomics
Verified
Journal Article
Closed access
SWSueAnn Woods
SueAnn Woods
ESEduardo M. Sosa
Eduardo M. Sosa
AKAmy Kurowski-Burt
Amy Kurowski-Burt
MFMarissa Fleming
Marissa Fleming
KMKristen Matheny
Kristen Matheny
IZIsabella Zornes
Isabella Zornes

1 March 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
ESEduardo M. Sosa
Eduardo M. Sosa
FAFaisal M. Alessa
Faisal M. Alessa

1 October 2015 in Thin-Walled Structures
Verified
Journal Article
Closed access
LGLuis A. Godoy
Luis A. Godoy
RJRossana C. Jaca
Rossana C. Jaca
ESEduardo M. Sosa
Eduardo M. Sosa
FFFernando G. Flores
Fernando G. Flores

19 August 2025 in Journal of Materials Processing Technology
Verified
Journal Article
Closed access
HAHavva E. Aysal
Havva E. Aysal
ESEduardo M. Sosa
Eduardo M. Sosa
RGRakesh K. Gupta
Rakesh K. Gupta
BPBrian Paul
Brian Paul
CCChih-Hung Chang
Chih-Hung Chang
KSKonstantinos A. Sierros
Konstantinos A. Sierros

4 April 2022 in International Journal of Occupational Safety and Ergonomics
Verified
Journal Article
Closed access
FAFaisal M. Alessa
Faisal M. Alessa
ESEduardo M. Sosa
Eduardo M. Sosa
Injuries to the hand and fingers with varying degrees of severity are widespread in industries such as mining and oil and gas production. This study presents the results of tests carried out to measure the impact performance for commonly used impact-resistant gloves (metacarpal gloves). Sets of surrogate hands made out of a 3D-printed skeletal structure and soft tissues represented by synthetic gel were manufactured and subjected to controlled impact tests. The calibration and validation of the surrogates were based on impact response data reported previously for cadaveric specimens. Calibrated surrogate hand specimens were tested to assess the impact protection of typical metacarpal gloves. Each type of metacarpal glove provided different levels of protection measured by the decrease in the peak impact reaction force and the fractures detected after the impacts. Results indicated that surrogate specimens suffered fractures in 77% and 33% of the impacts for unprotected and protected hands, respectively.