Hong Pu

Dr. Hong Pu


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in European Journal of Radiology
Verified
Journal Article
Closed access
Yuting WangYuting Wang
Yuting Wang
YLYing-Chun Li
Ying-Chun Li
LYLonglin Yin
Longlin Yin
HPHong Pu
Hong Pu

7 January 2022 in Clinical Radiology
Verified
Journal Article
Closed access
YWY. Wang
Y. Wang
XCX. Chen
X. Chen
HPHong Pu
Hong Pu
YYY. Yuan
Y. Yuan
SLS. Li
S. Li
HLHang Li
Hang Li

24 November 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
LSLan Shang
Lan Shang
FWFang Wang
Fang Wang
YGYan Gao
Yan Gao
CZChaoxin Zhou
Chaoxin Zhou
JWJian Wang
Jian Wang
WKWeifang Kong
Weifang Kong
Background: This study aimed to investigate the diagnostic value of machine-learning (ML) models with multiple classifiers based on non-enhanced CT Radiomics features for differentiating anterior mediastinal cysts (AMCs) from thymomas, and high-risk from low risk thymomas.Methods: In total, 201 patients with AMCs and thymomas from three centers were included and divided into two groups: AMCs vs. thymomas, and high-risk vs low-risk thymomas. A radiomics model (RM) was built with 73 radiomics features that were extracted from the three-dimensional images of each patient. A combined model (CM) was built with clinical features and subjective CT finding features combined with radiomics features. For the RM and CM in each group, five selection methods were adopted to select suitable features for the classifier, and seven ML classifiers were employed to build discriminative models. Receiver operating characteristic (ROC) curves were used to evaluate the diagnostic performance of each combination.Results: Several classifiers combined with suitable selection methods demonstrated good diagnostic performance with areas under the curves (AUCs) of 0.876 and 0.922 for the RM and CM in group 1 and 0.747 and 0.783 for the RM and CM in group 2, respectively. The combination of support vector machine (SVM) as the feature-selection method and Gradient Boosting Decision Tree (GBDT) as the classification algorithm represented the best comprehensive discriminative ability in both group. Comparatively, assessments by radiologists achieved a middle AUCs of 0.656 and 0.626 in the two groups, which were lower than the AUCs of the RM and CM. Most CMs exhibited higher AUC value compared to RMs in both groups, among them only a few CMs demonstrated better performance with significant difference in group 1.Conclusion: Our ML models demonstrated good performance for differentiation of AMCs from thymomas and low-risk from high-risk thymomas. ML based on non-enhanced CT radiomics may serve as a novel preoperative tool.

1 June 2020 in Journal of Infection
Verified
Journal Article
Closed access
JZJie Zeng
Jie Zeng
SPShengkun Peng
Shengkun Peng
YLYu Lei
Yu Lei
JHJianxin Huang
Jianxin Huang
YGYang Guo
Yang Guo
PLPan Lingai
Pan Lingai

1 May 2018 in Medicine
Verified
Journal Article
Open access
PDF file
GCGuang-Wen Chen
Guang-Wen Chen
HLHang Li
Hang Li
HPHong Pu
Hong Pu
Interrupted aortic arch (IAA) is defined as a complete luminal and anatomical interruption between the ascending and descending aortas. The majority of patients with IAA rarely reach adulthood. In most cases, IAA is associated with an intracardiac malformation, such as ventricular septal defect, bicuspidaortic valve, and patent ductus arteriosus. We reported a 70-year-old man with isolated IAA diagnosed using computed tomography angiography (CTA) without previous intervention. The patient presented with edema of the lower extremities and productive cough. CTA displayed an interruption of the aortic arch distal to the left common carotid artery (type B) and extensive collateralization. The patient refused surgery and underwent conservative therapy with follow-up examinations because of the extensive collateral vascularization. The patient is still currently undergoing conservative therapy with follow-up examinations. IAA can present in adulthood with different clinical symptoms. Careful physical examination of the lower and upper peripheral pulses in adults with a chief complaint of hypertension is of outmost importance. CTA is a useful noninvasive imaging modality for the morphologic evaluation of aortic interruption and collateral circulation.

13 January 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SPShengkun Peng
Shengkun Peng
LPLingai Pan
Lingai Pan
YGYang Guo
Yang Guo
BGBo Gong
Bo Gong
XHXiaobo Huang
Xiaobo Huang
JZJie Zeng
Jie Zeng
Objectives: COVID-19 and Non-Covid-19 (NC) Pneumonia encountered high CT imaging overlaps during pandemic. The study aims to evaluate the effectiveness of image-based quantitative CT features in discriminating COVID-19 from NC Pneumonia. Materials and methods: 145 patients with highly suspected COVID-19 were retrospectively enrolled from four centers in Sichuan Province during January 23 to March 23, 2020. 88 cases were confirmed as COVID-19, and 57 patients were NC. The dataset was randomly divided by 3:2 into training and testing sets. The quantitative CT radiomics features were extracted and screened sequentially by correlation analysis, Mann-Whitney U test, the least absolute shrinkage and selection operator (LASSO) logistic regression (LR) and backward stepwise LR with minimum AIC methods. The selected features were used to construct the LR model for differentiating COVID-19 from NC. Meanwhile, the differentiation performance of traditional quantitative CT features such as lesion volume ratio, ground glass opacity (GGO) or consolidation volume ratio were also considered and compared with Radiomics-based method. The receiver operating characteristic curve (ROC) analysis were conducted to evaluate the predicting performance. Results: Compared with traditional CT quantitative features, radiomics features performed best with the highest Area Under Curve (AUC), sensitivity, specificity and accuracy in the training (0.994, 0.942, 1.0 and 0.965) and testing sets (0.977, 0.944, 0.870, 0.915) (Delong test, P < 0.001). Among CT volume-ratio based models using lesion or GGO component ratio, the model combining CT lesion score and component ratio performed better than others, with the AUC, sensitivity, specificity and accuracy of 0.84, 0.692, 0.853, 0.756 in the training set and 0.779, 0.667, 0.826, 0.729 in the testing set. The significant difference of the most selected wavelet transformed radiomics features between COVID-19 and NC might well reflect the CT signs. Conclusions: The differentiation between COVID-19 and NC could be well improved by using radiomics features, compared with traditional CT quantitative values.