In this study, an innovative fabricated angle bracket connection for joining cold-formed steel structures is presented and investigated. The innovation lies in the especially designed and manufactured angle bracket and in the method of connecting the angle bracket for the C-profile using clinch pressing. This novel angle bracket can be used to connect cold-formed steel elements such as beam trusses at the ends of the chords or for anchoring the column base. Five specimens were fabricated and experimentally tested under monotonic tensile loading until failure. A specific tool was developed to properly hold C-profiles. Three displacement measurement procedures were performed, and the appropriate method was used to analyse the test results. The main failure mechanism of the angle bracket connection determined by the tests was pull-through of the M12 bolt, whose resistance is compared with the calculated values according to the AISI S100-16 and EN 1993-1-3 standards. There was no bearing failure in the innovative connection between the C-profile and the angle bracket, which indicates an increase in the bearing capacity of the connection.
This paper presents an experimental and numerical investigation of the tensile and compressive behaviour of a novel U-connector in the cold-formed steel (CFS) truss-to-column connection. Tensile tests were performed on 12 specimens representing the tension chords of the trusses in the connection. The results were used to validate a finite element model. The validated model was then subjected to both compressive and tensile loads, which revealed low stiffness in both the compressive and tensile components of the proposed connection. An optimisation of the geometry by using one long nut instead of two nuts was carried out to improve the behaviour and stiffness of the connection. The optimised results were compared with both experimental and numerical data, and conclusions were drawn regarding the effectiveness of the components in the proposed connection. The use of long-nut optimisation in the tension and compression components of the proposed connection shows a significant increase in load-bearing capacity, which makes it very promising for future applications in CFS truss-to-column connections. However, further validation through experimental testing is required to confirm the effectiveness and reliability of the connection in full-scale structures.
This study presents an innovative design for a cold-formed steel polyurethane (CFS-PU) composite wall panel, combining a cold-formed steel frame, a polyurethane foam infill, and a gypsum fibreboard sheathing. The foam filling process, in which the foam is injected under pressure, ensures uniform distribution, bonding, and interaction of all panel components. The aim of the study is to evaluate the behaviour of the CFS-PU composite panels and the influence of the PU foam and sheathing on the performance of the CFS frame structure. For this purpose, a comprehensive test programme was conducted with nine full-scale specimens, including four CFS-F specimens without infill and sheathing and five CFS-PU specimens with infill and sheathing on both sides. The study examined various aspects of the specimens, including failure modes, stability, stiffness, load-bearing capacity, and ductility index. By analysing these parameters, valuable insights were gained into the performance characteristics of the composite wall panels. The load-bearing capacity of the CFS-PU test specimens was improved by 2.34 times and the stiffness by 1.47 times compared to the CFS-F test specimens. The positive results highlight the potential of foam and sheathing in improving the axial compression performance of CFS walls.
1 August 2025 in Modern structures of metal and wood
The research focuses on evaluating the mechanical contribution of the PU foam and sheathing to the load-bearing capacity, stiffness, and failure modes of the LSF system. Two groups of specimens were tested under axial compression: (1) bare LSF structures consisting solely of cold-formed C-profiles, and (2) composite panels consisting of the same LSF frame, a PU foam core injected under pressure, and external gypsum fibreboard sheathing. The experimental results demonstrate a substantial enhancement in structural performance due to composite action. Composite panels achieved an average load-bearing capacity of 316.7 kN, more than double that of the bare LSF structures, which averaged 133.4 kN. In addition, the composite panels exhibited significantly higher ductility, with average vertical displacements at peak load reaching 10.27 mm, compared to 5.43 mm for the LSF frames. The initial stiffness of the composite system was also markedly improved, reaching 45.76 kN/mm approximately 1.5 times greater than that of the LSF structure alone. The PU foam, injected in a controlled industrial process, ensures a uniform and firm bond with both the steel frame and the sheathing, enabling effective composite action and resistance to local and global buckling. Visual inspection and load-displacement analysis confirmed that while the bare LSF structures failed by local and out-of-plane buckling, the composite panels maintained stability and failed primarily through localized crushing, without global loss of structural integrity. These findings underscore the structural benefits of using composite panel systems and provide a foundation for the development of design models and future standardization of this type of construction element.
U ovom radu istražuje se mehaničko ponašanje T-spojeva izrađenih od hladnooblikovanih čeličnih C-profila spojenih samonareznim vijcima, s posebnim naglaskom na utjecaj debljine profila i načina izvedbe otvora na nosivost spoja. Analizirani su spojevi s dvije debljine limova, 0,95 mm i 1,15 mm, te dvije varijante otvora – bez ojačanja i s ojačanjem postignutim plastičnim oblikovanjem. Numeričke simulacije provedene su u programu ABAQUS, a valjanost modela potvrđena je usporedbom s relevantnim rezultatima iz literature. Rezultati pokazuju da povećanje debljine limova za približno 21 % rezultira povećanjem maksimalne nosivosti spoja za 15,2 %, ali i promjenom oblika otkazivanja, pri čemu se kritično mjesto otkazivanja premjestilo s čeličnih profila na vijak. Uvođenje ojačanja otvora značajno poboljšava raspodjelu naprezanja i smanjuje lokalne deformacije oko vijčanih rupa. Kod tanjih profila, ojačanje dovodi do povećanja nosivosti za 19,8 %, dok je kod debljih limova porast nosivosti znatno izraženiji, čak 46,7 %. Ojačanje otvora time povećava otpornost spoja na lokalne deformacije i omogućuje bolje iskorištenje kapaciteta čeličnih profila bez prekoračenja njihove granice popuštanja. Pravilan odabir debljine limova, kvalitete vijaka i izvedbe otvora pokazuje se ključnim za osiguranje optimalne nosivosti i sigurnosti T-spojeva u tankostjenim čeličnim konstrukcijama. Dobiveni rezultati predstavljaju vrijedan doprinos razumijevanju ponašanja i optimizaciji spojeva u suvremenim konstrukcijama hladnooblikovanih elemenata.
Predstavljeno je istraživanje koje je provodeno u okviru znanstvenog-razvojnog projekta UNIRI INOVA „Inovativni priključak za spajanje konstrukcijskih elemenata od tankostijenih čeličnih C-profila“. Cilj projekta je pružiti bolje razumijevanje o ponašanju komponenti inovativnog priključka za spajanje elemenata od tankostijenih čeličnih C-profila.