Abhinav Sharma

Dr. Abhinav Sharma


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in The Bone & Joint Journal
Verified
Journal Article
Closed access
JVJonathan M. Vigdorchik
Jonathan M. Vigdorchik
ASAbhinav Sharma
Abhinav Sharma
ABAaron J. Buckland
Aaron J. Buckland
AEAmeer M. Elbuluk
Ameer M. Elbuluk
NENima Eftekhary
Nima Eftekhary
SJSeth A. Jerabek
Seth A. Jerabek
Aims: Patients with spinal pathology who undergo total hip arthroplasty (THA) have an increased risk of dislocation and revision. The aim of this study was to determine if the use of the Hip-Spine Classification system in these patients would result in a decreased rate of postoperative dislocation in patients with spinal pathology. Methods: This prospective, multicentre study evaluated 3,777 consecutive patients undergoing THA by three surgeons, between January 2014 and December 2019. They were categorized using The Hip-Spine Classification system: group 1 with normal spinal alignment; group 2 with a flatback deformity, group 2A with normal spinal mobility, and group 2B with a stiff spine. Flatback deformity was defined by a pelvic incidence minus lumbar lordosis of > 10°, and spinal stiffness was defined by < 10° change in sacral slope from standing to seated. Each category determined a patient-specific component positioning. Survivorship free of dislocation was recorded and spinopelvic measurements were compared for reliability using intraclass correlation coefficient. Results: A total of 2,081 patients met the inclusion criteria. There were 987 group 1A, 232 group 1B, 715 group 2A, and 147 group 2B patients. A total of 70 patients had a lumbar fusion, most had L4-5 (16; 23%) or L4-S1 (12; 17%) fusions; 51 patients (73%) had one or two levels fused, and 19 (27%) had > three levels fused. Dual mobility (DM) components were used in 166 patients (8%), including all of those in group 2B and with > three level fusions. Survivorship free of dislocation at five years was 99.2% with a 0.8% dislocation rate. The correlation coefficient was 0.83 (95% confidence interval 0.89 to 0.91). Conclusion: This is the largest series in the literature evaluating the relationship between hip-spine pathology and dislocation after THA, and guiding appropriate treatment. The Hip-Spine Classification system allows surgeons to make appropriate evaluations preoperatively, and it guides the use of DM components in patients with spinopelvic pathology in order to reduce the risk of dislocation in these high-risk patients. Cite this article: Bone Joint J 2021;103-B(7 Supple B):17–24.

15 December 2020 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
JVJonathan M. Vigdorchik
Jonathan M. Vigdorchik
ASAbhinav Sharma
Abhinav Sharma
SJSeth A. Jerabek
Seth A. Jerabek
DMDavid J. Mayman
David J. Mayman
PSPeter K. Sculco
Peter K. Sculco
Preoperative templating provides several benefits to the patient, surgeon, and hospital. Appropriate implant selection and sizing optimizes surgical workflow and leads to efficient care-delivery systems. Accurate templating establishes intraoperative targets for component position and reduces complications such as leg length inequality, impingement, wear, dislocation, and fracture, all of which lead to decreased patient satisfaction. Recent technological advances in preoperative imaging include a better understanding of patient-specific pelvic motion allowing the surgeon to preoperatively address the risk of lumbar pathology with adjustments in component placement and bearing choice. The introduction of two-dimensional to three-dimensional (3D) radiographs, biplanar low-dose radiographs, and computed tomography scans with 3D reconstructions have all allowed for a more comprehensive preoperative planning in 3D. This article will review the fundamentals of templating before total hip arthroplasty with an emphasis on how to incorporate and implement patient-specific pelvic motion and 3D templating into practice.

1 September 2020 in Journal of Orthopaedics
Verified
Journal Article
Open access
IGIoannis Gkiatas
Ioannis Gkiatas
ASAbhinav Sharma
Abhinav Sharma
AGAlexander Greenberg
Alexander Greenberg
SDStephen T. Duncan
Stephen T. Duncan
BCBrian P. Chalmers
Brian P. Chalmers
PSPeter K. Sculco
Peter K. Sculco
Dual mobility (DM) constructs effectively reduce the risk of dislocation in revision and high risk primary total hip arthroplasty. However, modular DM designs require the use of a cobalt-chrome liner against a titanium cup which may induce corrosion, metal ions release, and associated biologic response. The purpose of this systematic review study was to collect all reported cases of serum metal ions after DM in the literature and ask the following questions: 1) what is the overall rate of significantly elevated Cobalt and Chromium metal ions and how do these levels change over time? 2) Does femoral head material composition influence serum metal ion levels? and 3) were there any atypical lymphocytic associated lesions after modular DM that required revision surgery? A systematic review was performed according to PRISMA guidelines. In addition to patient demographics, information specific to the performance of the DM implant were recorded including: cobalt and chromium serum ion levels and all reported timepoints, the material composition of the femoral head, all revision and reoperations and any failure related to corrosion of the DM bearing. A significant elevation in cobalt or chromium was defined as >1.0 or >1.6 mcg/L. 248 modular DM THAs were analyzed. The cumulative mean cobalt and chromium levels for all included studies was 0.47mcg/L and 0.53mcg/L, respectively. At final follow-up 13 patients (5.2%) had elevated cobalt ion levels and 4 patients (1.6%) had elevated chromium ion levels. Femoral head material composition trended towards but did not significantly increase serum ion levels. Ceramic heads had elevated cobalt and chromium ions in 4/135 (3%) of patients compared to metal heads which had elevated cobalt ions in 9/113 (8%) and elevated chromium ions in 0/113 (0%), (p = 0.09). There were no reoperations or revisions for metal related reactions at final follow-up (mean 27.4 months). In this systematic review including 248 modular DM THAs, elevated serum cobalt ions were present in 5.2% of patients at a mean follow-up of 27.4 months. While a trend towards increased Cobalt serum ions with the use of cobalt chrome femoral heads, femoral head composition was not significantly associated with increased serum metal ion levels. At final follow-up, metal ion levels appear to decrease in the majority of patients between 1 and 2 years and no patient was revised for metal ion related complications. Continued serum metal ion surveillance is recommended to ensure the safety of DM constructs in THA with longer term follow-up.

1 July 2021 in JBJS Reviews
Verified
Journal Article
Closed access
ASAbhinav Sharma
Abhinav Sharma
AEAmeer M. Elbuluk
Ameer M. Elbuluk
IGIoannis Gkiatas
Ioannis Gkiatas
JKJulia M. Kim
Julia M. Kim
PSPeter K. Sculco
Peter K. Sculco
JVJonathan M. Vigdorchik
Jonathan M. Vigdorchik
» Mental health and psychosocial factors play a critical role in clinical outcomes in orthopaedic surgery. » The biopsychosocial model of disease defines health as a product of physiology, psychology, and social factors and, traditionally, has not been as emphasized in the care of musculoskeletal disease. » Improvement in postoperative outcomes and patient satisfaction is incumbent upon the screening, recognition, assessment, and possible referral of patients with high-risk psychosocial factors both before and after the surgical procedure.

1 September 2021 in Journal of Orthopaedics
Verified
Journal Article
Closed access
ASAbhinav Sharma
Abhinav Sharma
ZCZlatan Cizmic
Zlatan Cizmic
DDDouglas A. Dennis
Douglas A. Dennis
SKStefan W. Kreuzer
Stefan W. Kreuzer
MMMichael A. Miranda
Michael A. Miranda
JVJonathan M. Vigdorchik
Jonathan M. Vigdorchik

31 March 2025 in Neurospine
Verified
Journal Article
Open access
PDF file
ASAbhinav Sharma
Abhinav Sharma
RORafael Garcia de Oliveira
Rafael Garcia de Oliveira
SSSiravich Suvithayasiri
Siravich Suvithayasiri
PCPiya Chavalparit
Piya Chavalparit
CCChien Chun Chang
Chien Chun Chang
DPDon Young Park
Don Young Park
Endoscopic spine surgery (ESS) is growing in popularity worldwide. An expanding body of literature demonstrates rapid functional recovery with reduced morbidity compared to open techniques. Both full endoscopic spine surgery, or uniportal endoscopy, and unilateral biportal endoscopy (UBE) can be employed in conjunction with various navigation and enabling technologies for assistance with localization of anatomic orientation and assessment of the intraoperative target spinal pathology. This review article describes various navigation technologies in ESS, including 2-dimensional (2D) fluoroscopic imaging, 2D fluoroscopic navigation, 3-dimensional C-arm navigation, augmented reality, and spinal robotics. Employment of enabling navigation and emerging technology with the registration of patient-specific anatomy enables clear delineation of anatomic landmarks and facilitation of a successful procedure. Additionally, avoidance of common pitfalls during use of navigation systems in ESS is discussed in this review.