Samer Adeeb

Dr. Samer Adeeb

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 June 2014 in The Spine Journal
Verified
Journal Article
Closed access
Amin KomeiliAmin Komeili
Amin Komeili
LWLindsey M. Westover
Lindsey M. Westover
EPEric C. Parent
Eric C. Parent
MMMarc Moreau
Marc Moreau
MEMarwan El-Rich
Marwan El-Rich
SASamer Adeeb
Samer Adeeb

20 May 2015 in Frontiers in Endocrinology
Verified
Journal Article
Open access
PDF file
YWYuchin Wu
Yuchin Wu
SASamer Adeeb
Samer Adeeb
Michael DoschakMichael Doschak
Michael Doschak
Micro-computed tomography images can be used to quantitatively represent bone geometry through a range of computed attenuation-based parameters. Nonetheless, those parameters remain indirect indices of bone micro-architectural strength and require further computational tools to interpret bone structural stiffness and potential for mechanical failure. Finite element analysis (FEA) can be applied to measure trabecular bone stiffness and potentially predict the location of structural failure in preclinical animal models of osteoporosis, although that procedure from image segmentation of micro-CT derived bone geometry to FEA is often challenging and computationally expensive, resulting in failure of the model to build. Notably, the selection of resolution and threshold for bone segmentation are key steps that greatly affect computational complexity and validity. In the following study, we evaluated an approach whereby Micro-CT derived greyscale attenuation and segmentation data guided the selection of trabecular bone for analysis by FEA. We further correlated those FEA results to both two and three dimensional bone microarchitecture from sham and ovariectomized (OVX) rats (n=10/group). A virtual cylinder of vertebral trabecular bone 40% in length from the caudal side was selected for FEA because micro-CT based image analysis indicated the largest differences in microarchitecture between the two groups resided there. Bone stiffness was calculated using FEA and statistically correlated with the three dimensional values of bone volume/tissue volume, bone mineral density, fractal dimension, trabecular separation and trabecular bone pattern factor. Our method simplified the process for the assessment of trabecular bone stiffness by FEA from Micro-CT images and highlighted the importance of bone microarchitecture in conferring significantly increased bone quality capable of resisting failure due to increased mechanical loading.

1 May 2014 in Bone & Joint Research
Verified
Journal Article
Open access
PDF file
KIKamrul Islam
Kamrul Islam
ADA. Dobbe
A. Dobbe
Amin KomeiliAmin Komeili
Amin Komeili
KDK. Duke
K. Duke
MEMarwan El-Rich
Marwan El-Rich
NJN. M. Jomha
N. M. Jomha
The main object of this study was to use a geometric morphometric approach to quantify the left-right symmetry of talus bones.

1 April 2017 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
BVB. Vafaeian
B. Vafaeian
DZD. Zonoobi
D. Zonoobi
MMM. Mabee
M. Mabee
AHAbhilash Rakkunedeth Hareendranathan
Abhilash Rakkunedeth Hareendranathan
MEMarwan El-Rich
Marwan El-Rich
JJJacob Lester Jaremko
Jacob Lester Jaremko

1 January 2016 in International Journal of Shoulder Surgery
Verified
Journal Article
Open access
PDF file
SASamer Adeeb
Samer Adeeb
SHShannon W Hill
Shannon W Hill
CCChristopher R Chapman
Christopher R Chapman
KDKajsa Duke
Kajsa Duke
LBLauren A Beaupre
Lauren A Beaupre
MBMartin J Bouliane
Martin J Bouliane
Background: The Nice knot is a bulky double-stranded knot. Biomechanical data supporting its use as well as the number of half hitches required to ensure knot security is lacking. Materials and Methods: Nice knots with, one, two, or three half-hitches were compared with the surgeon's and Tennessee slider knots with three half hitches. Each knot was tied 10 times around a fixed diameter using four different sutures: FiberWire (Arthrex, Naples, FL), Ultrabraid (Smith and Nephew, Andover, MA), Hi-Fi (ConMed Linvatec, Largo, FL) and Force Fiber (Teleflex Medical OEM, Gurnee, IL). Cyclic testing was performed for 10 min between 10N and 45N, resulting in approximately 1000 cycles. Displacement from an initial 10N load was recorded. Knots surviving cyclic testing were subjected to a load to failure test at a rate of 60 mm/min. Load at clinical failure: 3 mm slippage or opening of the suture loop was recorded. Bulk, mode of ultimate failure, opening of the loop past clinical failure, was also recorded. Results: During cyclic testing, the Nice knots with one or more half-hitches performed the best, slipping significantly less than the surgeon's and Tennessee Slider (P < 0.002). After one half-hitch, the addition of half-hitches did not significantly improve Nice knot performance during cyclic testing (P > 0.06). The addition of half-hitches improved the strength of the Nice knot during the force to failure test, however after two half-hitches, increase of strength was not significant (P = 0.59). While FiberWire was the most bulky of the sutures tested, it also performed the best, slipping the least. Conclusion: The Nice knot, especially using FiberWire, is biomechanically superior to the surgeon's and Tennessee slider knots. Two half hitches are recommended to ensure adequate knot security. The level of Evidence: 2, prospective comparative study.