Marco Malvezzi Caracciolo D'Aquino

Marco Malvezzi Caracciolo D'Aquino

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2023 in Antioxidants
Verified
Journal Article
Open access
PDF file
LFLuigi Falco
Luigi Falco
VTViviana Tessitore
Viviana Tessitore
GCGiovanni Ciccarelli
Giovanni Ciccarelli
MDMarco Malvezzi Caracciolo D'Aquino
Marco Malvezzi Caracciolo D'Aquino
Antonello D'AndreaAntonello D'Andrea
Antonello D'Andrea
Vincenzo RussoVincenzo Russo
Vincenzo Russo
The thrombosis-related diseases are one of the leading causes of illness and death in the general population, and despite significant improvements in long-term survival due to remarkable advances in pharmacologic therapy, they continue to pose a tremendous burden on healthcare systems. The oxidative stress plays a role of pivotal importance in thrombosis pathophysiology. The anticoagulant and antiplatelet drugs commonly used in the management of thrombosis-related diseases show several pleiotropic effects, beyond the antithrombotic effects. The present review aims to describe the current evidence about the antioxidant effects of the oral antithrombotic therapies in patients with atherosclerotic disease and atrial fibrillation.

Verified
Journal Article
Open access
PDF file
CGCarmen Del Giudice
Carmen Del Giudice
MGMario Giordano
Mario Giordano
GCGiovanni Ciccarelli
Giovanni Ciccarelli
GBGiuseppe Bassi
Giuseppe Bassi
MDMarco Malvezzi Caracciolo D'Aquino
Marco Malvezzi Caracciolo D'Aquino
PLPatrizio Lancellotti
Patrizio Lancellotti
Percutaneous patent foramen ovale (PFO) closure by traditional, double disc occluder devices was shown to be safe for patients with PFO, and more effective than prolonged medical therapy in preventing recurrent thromboembolic events. The novel suture-mediated “deviceless” PFO closure system overcomes most of the risks and limitations associated with the traditional PFO occluders, appearing to be feasible in most interatrial septum anatomies, even if data about its long-term effectiveness and safety are still lacking. The aim of the present review was to provide to the reader the state of the art about the traditional and newer techniques of PFO closure, focusing both on the procedural aspects and on the pivotal role of transesophageal echocardiography (TEE) in patient’s selection, peri-procedural guidance, and post-interventional follow-up.

1 February 2024 in Annals of Internal Medicine: Clinical Cases
Verified
Journal Article
Closed access
CGCarmen Del Giudice
Carmen Del Giudice
RCRenato Cosimo
Renato Cosimo
MDMarco Malvezzi Caracciolo D'Aquino
Marco Malvezzi Caracciolo D'Aquino
EPEnrica Pezzullo
Enrica Pezzullo
RBRossana Bussani
Rossana Bussani
FLFRANCESCO LOFFREDO
FRANCESCO LOFFREDO

18 May 2023 in European Heart Journal Supplements
Verified
Journal Article
Open access
PDF file
RCR Cosimo
R Cosimo
CPC Palomba
C Palomba
MDMarco Malvezzi Caracciolo D'Aquino
Marco Malvezzi Caracciolo D'Aquino
GSGiancarlo Scognamiglio
Giancarlo Scognamiglio
Simona SperlonganoSimona Sperlongano
Simona Sperlongano
PGPaolo Golino
Paolo Golino
History of presentation A 76–year–old woman presented to our EchoLab for worsening exertional dyspnea. Few weeks prior the patient underwent cardiological examination that showed heart failure with preserved ejection fraction (HFpEF) with bilateral pleuric effusion, severe mitralic regurgitation (MR), moderate tricuspid regurgitation (TR) with an estimated systolic pulmonary artery pressure (sPAP) of 50 mmHg and a mildly increased mean gradient on bioprothesic aortic valve (26 mmHg). Past medical history The patient had a medical history significant for arterial hypertension, hyperlipidemia, diabetes mellitus, permanent atrial fibrillation and HCV–related liver disease. She received double surgical aortic valve replacement in 2015 and 2019, the second procedure was complicated by intraoperatory stretching of mitral anterior leaflet and atrioventricular block treated with implantation of bicameral PMK. In the following weeks, the patient was admitted to hospital for exposure of the PMK generator pocket associated to catether cultures positivity for S. Aureus oxacilline–resistant, thus undergoing to device removal and positioning of a new PMK. Investigations The cardio–thoracic auscultation revealed a bilateral basal reduction of vesicular breath sounds, an apical sweet systolic murmur (suggestive of MR) and a systolic small aortic murmur best heard at the second intercostal space. The transthoracic echocardiography showed a blood flow apparently originating from interatrial septum heading towards the free left atrial wall. The Transoesophageal Echocardiography (TEE) with bubble test ruled out any interatrial communication. The 3D TEE acquisitions clarified that the shunt arose from the left ventricular outflow tract (LVOT), thus allowing the diagnosis of fistula between the LVOT and the left atrium. Follow–up and conclusions The patient underwent a procedure of percutaneous closure of the fistula. One month after this intervention, the patient presented to our department for the cardiological follow–up. We noticed that the closure had been successful with no left residual shunts and a reduction of the transprothesic mean aortic gradient (18 mmHg). This case report highlights the importance of the 3D echocardiography in order to settle uncertain diagnostics whereas the 2D echocardiography alone is not sufficient. Nevertheless, the diagnostic challenge that remains open is to understand whether the etiology of the fistula is iatrogenic or post–infectious.