Nazım İmal

Dr. Nazım İmal

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2013 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
MKMehmet Cemil Kale
Mehmet Cemil Kale
JFJohn David Fleig
John David Fleig
NİNazım İmal
Nazım İmal
Our aim was to analyze the feasibility of computer aided malignant tumor detection using the traditional texture analysis applied on two-compartment-based parameter pseudoimages of dynamic contrast-enhanced magnetic resonance (DCE-MR) breast image data. A major contribution of this research will be the through-plane assessment capability. Texture analysis was performed on two-compartment-based pseudo images of DCE-MRI datasets of breast data of eight subjects. The resulting texture parameter pseudo images were inputted to a feedforward neural network classification system which uses the manual segmentations of a primary radiologist as a gold standard, and each voxel was assigned as malignant or nonmalignant. The classification results were compared with the lesions manually segmented by a second radiologist. Results show that the mean true positive fraction (TPF) and false positive fraction (FPF) performance of the classifier vs. primary radiologist is statistically as good as the mean TPF and FPF performance of the second radiologist vs. primary radiologist with a confidence interval of 95% using a one-sample -test with . In the experiment implemented on all of the eight subjects, all malignant tumors marked by the primary radiologist were classified to be malignant by the computer classifier. Our results have shown that neural network classification using the textural parameters for automated screening of two-compartment-based parameter pseudo images of DCE-MRI as input data can be a supportive tool for the radiologists in the preassessment stage to show the possible cancerous regions and in the postassessment stage to review the segmentations especially in analyzing complex DCE-MRI cases.

23 February 2026 in Multidiscipline Modeling in Materials and Structures
Verified
Journal Article
Closed access
NİNazım İmal
Nazım İmal
BÖBurak Öztürk
Burak Öztürk
EAEmir Sadık Arın
Emir Sadık Arın
Purpose: This study investigates the optimization of (Unmanned Aerial Vehicle) UAV-based illumination systems using experimental design, Dialux simulations, and image processing methods, with a focus on maximizing lighting performance while minimizing energy consumption. Design/methodology/approach: A full factorial experimental design with four factors (circuit status, spot angle, height, and spot efficiency) at multiple levels was employed. Dialux software was used to calculate horizontal and vertical illuminance values and homogeneity indices, while Python-based image processing (OpenCV and polynomial regression) extracted detailed illumination profiles. Response Surface Methodology (RSM) was applied in Minitab to evaluate factor significance and to determine the optimal parameter set. Findings: The results showed that spot efficiency was the most dominant factor (p < 0.001) across all responses, while height significantly influenced horizontal average illuminance (p = 0.000). The maximum horizontal illuminance (Eyavg) of 7.10 lux was achieved at 10 m with narrow beam efficiency, whereas the minimum specific lighting energy consumption - Ey (SLEC Ey) was 0.010 W/lux under the same conditions. RSM optimization yielded a composite desirability of 1.000, indicating perfect agreement with the target objectives. Model reliability was confirmed with high coefficients of determination (R2 = 86–99%). Originality/value: This study introduces a novel optimization framework for UAV-based illumination systems by integrating experimental lighting performance data with RSM. Unlike previous research that mainly focused on communication or surveillance aspects of drones, our work emphasizes quantitative analysis of lighting efficiency and energy consumption under varying operational factors. The combination of ANOVA modeling, surface plots, and desirability functions provides statistically robust results and identifies the optimum operational parameters with high accuracy.

30 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
AEANWAR ELASYRI
ANWAR ELASYRI
NİNazım İmal
Nazım İmal
MFMehmet Fidan
Mehmet Fidan
Electrical power systems are exposed to interacting electrical, thermal, environmental, and resource-related faults such as leakage current, voltage and frequency deviations, overcurrent, harmonic distortion, phase-sequence error, humidity, fire, wind-speed variability, water insufficiency, and solar-resource loss. This study introduces a software-based database-generation and smart-learning framework that converts 22 candidate risk factors into six normalized severity levels and then maps the simultaneous system state to low-, medium-, and high-level protection decisions. The main novelty is that the software not only evaluates existing measurements; it also produces a literature- and standards-informed synthetic database when long-term real field measurements are not yet available. The database is generated by defining variable limits, sampling realistic operating states, computing severity labels, and storing input–output pairs that can later train or validate predictive maintenance models. The proposed framework therefore, links protection logic, database construction, and reusable training data in a single workflow. The results show how simulated annual operating scenarios can be transformed into structured risk records, warning classes, and shutdown decisions, supporting early fault detection, maintenance planning, and resilience improvement in renewable-integrated electrical networks.

5 June 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
AEANWAR ELASYRI
ANWAR ELASYRI
NİNazım İmal
Nazım İmal
MFMehmet Fidan
Mehmet Fidan
Electrical power systems are exposed to interacting electrical, thermal, environmental, and resource-related faults such as leakage current, voltage and frequency deviations, overcurrent, harmonic distortion, phase-sequence error, humidity, fire, wind-speed variability, water insufficiency, and solar-resource loss. This study introduces a software-based database-generation and smart-learning framework that converts 22 candidate risk factors into six normalized severity levels and then maps the simultaneous system state to low-, medium-, and high-level protection decisions. The main novelty is that the software does not only evaluate existing measurements; it also produces a literature- and standards-informed synthetic database when long-term real field measurements are not yet available. The database is generated by defining variable limits, sampling realistic operating states, computing severity labels, and storing input-output pairs that can later train or validate predictive maintenance models. The proposed framework therefore links protection logic, database construction, and reusable training data in a single workflow. The results show how simulated annual operating scenarios can be transformed into structured risk records, warning classes, and shutdown decisions, supporting early fault detection, maintenance planning, and resilience improvement in renewable-integrated electrical networks.

21 November 2025 in Engineering Computations
Verified
Journal Article
Closed access
NİNazım İmal
Nazım İmal
BÖBurak Öztürk
Burak Öztürk
Purpose: This study aims to optimize stadium lighting energy consumption while ensuring maximum visual quality. Stadium lighting is essential for athletes’ performance, audience experience and broadcast quality. However, illuminating large areas incurs high energy costs. The main motivation is to develop a multi-objective optimization approach that enhances energy efficiency and lighting performance simultaneously. Design/methodology/approach: A custom MATLAB-based optimization model was developed to analyze stadium lighting performance. Experiments were conducted to evaluate the impact of pole height, field distance (X and Y axes) and fixture count on lighting efficiency. A multi-objective optimization framework was designed using response surface methodology (RSM), with 18 experimental runs performed. Findings: The optimal lighting setup was achieved in the fourth experiment, yielding 1,213 Lux (horizontal) and 1724 Lux (vertical) illumination. The validation experiment confirmed improvements, reaching 1,350 Lux (horizontal) and 1825 Lux (vertical), differing from RSM-based experiments. These results were obtained with energy consumption of 277 W/Lux (horizontal) and 205 W/Lux (vertical). The proposed optimization method resulted in a 32% improvement in energy efficiency and a 42% enhancement in lighting performance. The accuracy of the model was validated through real-field testing, achieving 89.1%–94.5% agreement with experimental results. Originality/value: This study presents a novel optimization approach for stadium lighting, contributing to energy savings, uniform illumination and lighting performance enhancement. For the first time in the literature, the energy required per unit lux (W/Lux) was systematically defined and analyzed using the special lighting energy consumption (SLEC) metric.

10 March 2026 in Machines
Verified
Journal Article
Open access
PDF file
NİNazım İmal
Nazım İmal
BÖBurak Öztürk
Burak Öztürk
Tunnel lighting systems serving pedestrian and vehicular traffic must simultaneously satisfy visual performance requirements and energy efficiency constraints. This study investigates the optimization of tunnel lighting design using a sustainable engineering approach based on Response Surface Methodology (RSM) and Specific Lighting Energy Consumption (SLEC). Software-assisted lighting simulations were performed for two tunnel geometries—straight and double-curved—and horizontal (Eh) and vertical (Ev) illuminance levels were evaluated at five representative locations. The resulting data were used to construct RSM-based predictive models and to assess energy performance through SLEC. The effects of mounting height, luminaire spacing, luminous flux, number of luminaires, and tunnel type were systematically analyzed. The results demonstrate that luminaire spacing is the dominant parameter influencing illuminance levels and energy consumption. An optimal configuration consisting of a 12 m luminaire spacing, 5 m mounting height, and 10,000–12,000 lm luminous flux achieved a favorable balance between lighting quality and energy efficiency. Additionally, straight tunnels exhibited higher illuminance uniformity at shorter spacings, whereas curved tunnels showed improved performance under wider spacing conditions. The proposed RSM–SLEC framework provides a robust, data-driven methodology for sustainable tunnel lighting design without compromising safety or visual comfort.