Chaotan Sima

Prof. Dr. Chaotan Sima

School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2022 in ACS Nano
Verified
Journal Article
Closed access
JLJunling Lu
Junling Lu
SHSanming Hu
Sanming Hu
WLWenru Li
Wenru Li
XWXuefang Wang
Xuefang Wang
XMXiwei Mo
Xiwei Mo
GZGuangzu Zhang
Guangzu Zhang

12 April 2022 in Photoacoustics
Verified
Journal Article
Open access
HXHanping Xiao
Hanping Xiao
JZJinbiao Zhao
Jinbiao Zhao
CSChaotan Sima
Chaotan Sima
Ping LuPing Lu
Ping Lu
YLYanhong Long
Yanhong Long
DLDeming Liu
Deming Liu
In this paper, we propose and experimentally demonstrate an ultra-sensitive all-optical PAS gas sensor, incorporating with a near-infrared (NIR) diode laser, fiber-optic microphones (FOMs) and a double channel differential T-type photoacoustic cell. The FOM is realized by Fabry-Perot interferometry and novel gold-chromium (Au-Cr) composite nanomembranes. To meet the demand of high sensitivity and flat frequency response for the FOMs, the Au-Cr composite diaphragm is deliberately designed and fabricated by E-beam evaporation deposition with 330 nm in thickness and 6.35 mm in radius. Experimental results show that the FOM has a sensitivity of about 30 V/Pa and a flat frequency response from 300 to 900 Hz with fluctuation below 1 dB. Moreover, a double channel differential T-type photoacoustic cell is designed and employed in the all-optical PAS gas sensor, with the first-order resonant frequency of 610 Hz. The all-optical gas sensor is established and verified for CH4 detection and the normalized noise equivalent absorption (NNEA) is 4.42 × 10−10 W∙cm−1∙Hz−1/2. The minimum detection limit (MDL) of 36.45 ppb is achieved with a 1 s integration time. The MDL could be further enhanced to 4.87 ppb with an integration time of 81 s, allowing ultra-sensitive trace gas detection.

1 July 2023 in Photoacoustics
Verified
Journal Article
Open access
TLTailin Li
Tailin Li
CSChaotan Sima
Chaotan Sima
YAYan Ai
Yan Ai
CTChen Tong
Chen Tong
JZJinbiao Zhao
Jinbiao Zhao
PLPing Lu
Ping Lu
In this paper, we propose and experimentally demonstrate a symmetric multi-resonant cavity photoacoustic cell (MR-PAC) with dual microphones detection, based on multi-resonator photoacoustic spectroscopy (MR-PAS). The designed photoacoustic cell contains three interconnected acoustic resonators to facilitate simultaneous control of three lasers for multi-gas sensing. Two microphones are symmetrically located at both sides of photoacoustic cell to implement two-point detection. The length of acoustic resonator is about 50 mm to minimize the photoacoustic cell, and the resonant frequency is around 3000 Hz. Feasibility and performance of the MR-PAC was demonstrated by simultaneous detection of C2H2, NO and CF4 using a near infrared diode laser and two mid infrared quantum cascade lasers. The minimum detection limits (MDLs) of C2H2, NO and CF4 are 480 ppb, 260 ppb and 0.57 ppb respectively with a 1 s integration time at normal atmospheric pressure. This minimized MR-PAS system is promising for the portable multi-gas sensing.

30 June 2022 in Photoacoustics
Verified
Journal Article
Open access
LFLujun Fu
Lujun Fu
Ping LuPing Lu
Ping Lu
CSChaotan Sima
Chaotan Sima
JZJinbiao Zhao
Jinbiao Zhao
YPYufeng Pan
Yufeng Pan
DLDeming Liu
Deming Liu
A small-volume highly-sensitive photoacoustic spectroscopy (PAS) methane detection system based on differential silicon cantilever optical microphones (SCOMs) is proposed and experimentally demonstrated. The system contains a compact non-resonant photoacoustic cell with a small volume of 1.2 mL and symmetrically-located dual SCOMs, as well as a distributed feedback laser at 1650.96 nm. The two identical SCOMs utilize the Fabry-Perot interferometric fiber-optic structure, with the differential Q-point demodulation algorithm to suppress the external vibration noise. Experimental results show that the SCOM has a high displacement sensitivity about 7.1 µm/Pa at 150 Hz and within 2.5 dB fluctuation between 5 Hz and 250 Hz. In the PAS gas sensing experiment, the normalized noise equivalent absorption coefficient of the PAS system is estimated to be 1.2 × 10−9 cm−1·W·Hz−1/2 and the minimum detection limit for methane is about 111.2 ppb with 1 s integration time. External disturbance is also applied to the dual SCOM system and results show excellent stability and noise resistance. The proposed PAS system exhibits superiorities of low gas consumption, high sensitivity and immunity to vibration and electromagnetic interference, which has an enormous potential in medicine, industry and environment.

12 March 2025 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ZFZhiyu Feng
Zhiyu Feng
CSChaotan Sima
Chaotan Sima
TLTailin Li
Tailin Li
WWWenzhe Wang
Wenzhe Wang
YPYufeng Pan
Yufeng Pan
PLPing Lu
Ping Lu

27 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CTChen Tong
Chen Tong
CSChaotan Sima
Chaotan Sima
MCMuqi Chen
Muqi Chen
XZXiaohang Zhang
Xiaohang Zhang
TLTailin Li
Tailin Li
Ping LuPing Lu
Ping Lu
Tunable Diode Laser Absorption Spectroscopy (TDLAS) has been widely applied in in situ and real-time monitoring of trace gas concentrations. In this paper, an advanced TDLAS-based optical gas sensing system with laser linewidth analysis and filtering/fitting algorithms is proposed and experimentally demonstrated. The linewidth of the laser pulse spectrum is innovatively considered and analyzed in the harmonic detection of the TDLAS model. The adaptive Variational Mode Decomposition-Savitzky Golay (VMD-SG) filtering algorithm is developed to process the raw data and could significantly eliminate the background noise variance by about 31% and signal jitters by about 12.5%. Furthermore, the Radial Basis Function (RBF) neural network is also incorporated and applied to improve the fitting accuracy of the gas sensor. Compared with traditional linear fitting or least squares method (LSM), the RBF neural network brings along the enhanced fitting accuracy within a large dynamic range, achieving an absolute error of below 50 ppmv (about 0.6%) for the maximum 8000 ppmv methane. The proposed technique in this paper is universal and compatible with TDLAS-based gas sensors without hardware modification, allowing direct improvement and optimization for current optical gas sensors.