Natalija Bede Odorčić

Dr. Natalija Bede Odorčić

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Engineering Fracture Mechanics
Verified
Journal Article
Closed access
JOJoško Ožbolt
Joško Ožbolt
NONatalija Bede Odorčić
Natalija Bede Odorčić
Akanshu SharmaAkanshu Sharma
Akanshu Sharma
UMUwe Mayer
Uwe Mayer

1 March 2015 in International Journal of Impact Engineering
Verified
Journal Article
Closed access
NONatalija Bede Odorčić
Natalija Bede Odorčić
JOJoško Ožbolt
Joško Ožbolt
Akanshu SharmaAkanshu Sharma
Akanshu Sharma
BİBariş İrhan
Bariş İrhan

15 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
NONatalija Bede Odorčić
Natalija Bede Odorčić
GKGregor Kravanja
Gregor Kravanja
There is a need to develop new construction materials with improved mechanical performance and durability that are low-priced and have environmental benefits at the same time. This paper focuses on the rheological, mechanical, morphological, and durability properties of synthetic and steel fiber reinforced self-compacting concrete (SCC) containing 5–15% metakaolin (M) by mass as a green replacement for Portland cement. Testing of the fresh mixes included a slump-flow test, density, and porosity tests. Mechanical properties were determined through compression and flexural strength. A rapid chloride penetrability test (RCPT) and the chloride migration coefficient were used to assess the durability of the samples. A scanning electron microscope (SEM) with energy dispersion spectrometry (EDS) was used to study the concrete microstructure and the interfacial transition zone (ITZ). The results show that a combination of metakaolin and hybrid fibers has a negative effect on the flowability of SCC. In contrast, the inclusion of M and hybrid fibers has a positive effect on the compressive and flexural strength of SCC. The fracture of SCC samples without fibers was brittle and sudden, unlike the fiber-reinforced SCC samples, which could still transfer a considerable load with increasing crack mouth opening deflection. Overall, the chloride migration coefficients were reduced by up to 71% compared to the control mix. The chloride reduction is consistent with the resulting compact concrete microstructure, which exhibits a strong bond between fibers and the concrete matrix.

26 January 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
AMAhmad Rizwan Mumtaz
Ahmad Rizwan Mumtaz
NONatalija Bede Odorčić
Natalija Bede Odorčić
NGNúria Garro
Núria Garro
SLSamo Lubej
Samo Lubej
AIAndrej Ivanič
Andrej Ivanič
GKGregor Kravanja
Gregor Kravanja
This study explores the potential of using basalt reinforced UHPC by incorporating simultaneously self-cleaning and self-luminescent features, paving the way for sustainable advancements in civil engineering. New green formulations of UHPC were developed by integrating supplementary cementitious materials and optimizing water to the binder ratio, followed by using basalt fibers to enhance strength and ductility. The fabricated samples with high particle-packing density exhibit sufficient workability and compressive strength up to 136 MPa, and, when incorporating basalt fibers, a notable reduction in brittleness. The inner microstructure of basalt fibers was observed to be smooth, homogeneously distributed, and well adhered to the UHPC matrix. To ensure the desired long-lasting visual appearance of decorative UHPC and reduce future maintenance costs, a time-effective strategy for creating a light-emitting biomimetic surface design was introduced. The samples exhibit high surface roughness, characterized by micro to nano-scale voids, displaying superhydrophobicity with contact angles reaching up to 155.45°. This is accompanied by roll-off angles decreasing to 7.1°, highlighting their self-cleaning features. The self-luminescence feature showcased intense initial light emission, offering a potential energy-efficient nighttime lighting solution.

1 January 2018 in Journal of the Croatian Association of Civil Engineers
Verified
Journal Article
Open access
PDF file
NONatalija Bede Odorčić
Natalija Bede Odorčić
PGPhilipp Grosser
Philipp Grosser
JOJoško Ožbolt
Joško Ožbolt
Shear breakout capacity of various fastening systems in concrete elements The results of a test program carried out to investigate the difference in the concrete breakout capacity of various fastening systems installed parallel to the edge of a concrete member, and loaded in shear towards the edge of the concrete member, are presented and analysed. According to the current design recommendations, the calculated concrete breakout capacity of anchor channels yields to a lower failure capacity compared to headed anchors. Welded anchors (headed anchors welded to a steel plate) and bonded anchors are also tested. Based on the test results, various fastening systems in concrete elements are compared.

1 June 2020 in Journal of Maritime & Transportation Science
Verified
Journal Article
Open access
PDF file
SMSilvija Mrakovcic
Silvija Mrakovcic
NONatalija Bede Odorčić
Natalija Bede Odorčić
IUIvan Ušić
Ivan Ušić
Corrosion of reinforcement is one of basic destruction mechanisms of reinforced concrete structures. In that sense, the most affected structures are those by the sea, especially their parts subjected to cycles of wetting and drying. Chlorides penetrate to concrete mostly by diffusion, faster if the concrete is more permeable, destructing reinforcement passive protection and causing its corrosion, reduction of reinforcement cross section and bearing capacity of the structure. Retardation of chloride corrosion that causes structure degradation in marine environment can be achieved by the usage of quality concrete with enhanced strength and permeability parameters in regards to ordinary concrete. Mixes of ordinary and high performance concrete with different ratio of silica fume have been made. Compressive strength and resistivity to chloride penetration have been tested on the specimens 28 days after mixing. The resistivity to chloride penetration has been determined by fast chloride penetration test according to ASTM C1202 standard, using appliance that measures electrical conductivity of concrete specimens. Based on test results, the suitability of building reinforced concrete structures by the sea using high performance concrete has been analysed.