Christian Herbert Ziener

Prof. Christian Herbert Ziener

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
SSSina Straub
Sina Straub
TSTill M. Schneider
Till M. Schneider
JEJulian Emmerich
Julian Emmerich
MFMartin T. Freitag
Martin T. Freitag
CZChristian Herbert Ziener
Christian Herbert Ziener
FLFrederik B. Laun
Frederik B. Laun

7 April 2009 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
VHVolker Herold
Volker Herold
MPMarco Parczyk
Marco Parczyk
PMPhilipp Mörchel
Philipp Mörchel
CZChristian Herbert Ziener
Christian Herbert Ziener
GKGert Klug
Gert Klug
PJPeter M. Jakob
Peter M. Jakob
Transgenic mouse models of human diseases have gained increasing importance in the pathophysiology of cardiovascular diseases (CVD). As an indirect measure of vascular stiffness, aortic pulse‐wave velocity (PWV) is an important predictor of cardiovascular risk. This study presents an MRI approach that uses a flow area method to estimate local aortic pulse‐wave velocity at different sites in the murine aorta. By simultaneously measuring the cross‐sectional area and the through‐plane velocity with a phase‐contrast CINE method, it was possible to measure average values for the PWV in the ascending and descending aorta within the range of 2.4–4.3 m/s for C57BL/6J mice (ages 2 and 8 months) and apoE‐knockout mice (age 8 months). Statistically significant differences of the mean values of the PWV of both groups could be determined. By repeating CINE measurements with a time delay of 1 ms between two subsequent data sets, an effective temporal resolution of 1000 frames/s (fps) could be achieved. Magn Reson Med, 2009.

15 July 2016 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
SSSina Straub
Sina Straub
FLFrederik B. Laun
Frederik B. Laun
JEJulian Emmerich
Julian Emmerich
BJBjörn Jobke
Björn Jobke
HHHenrik Hauswald
Henrik Hauswald
MRMatthias C. Röthke
Matthias C. Röthke

23 May 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ARAlexander Radbruch
Alexander Radbruch
JMJohanna Mucke
Johanna Mucke
FSFerdinand Schweser
Ferdinand Schweser
ADAndreas Deistung
Andreas Deistung
PRPeter Ringleb
Peter Ringleb
SRStefan Rohde
Stefan Rohde
Time-of-flight (TOF) angiography detects embolic occlusion of arteries in patients with acute ischemic stroke due to the absence of blood flow in the occluded vessel. In contrast, susceptibility weighted imaging (SWI) directly enables intravascular clot visualization due to hypointense susceptibility vessel signs (SVS) in the occluded vessel. The aim of this study was to compare the diagnostic accuracy of both methods to determine vessel occlusion in patients with acute stroke. 94 patients were included who presented with clinical symptoms for acute stroke and displayed a delay on the time-to-peak perfusion map in the territory of the anterior (ACA), middle (M1, M1/M2, M2/M3) or posterior (PCA) cerebral artery. The frequency of SVS on SWI and vessel occlusion or stenosis on TOF-angiography was compared using the McNemar-Test. 87 of 94 patients displayed a clearly definable SVS on SWI. In 72 patients the SVS was associated with occlusion or stenosis on TOF-angiography. Fifteen patients exclusively displayed SVS on SWI (14 M2/M3, 1 M1), whereas no patient revealed exclusively occlusion or stenosis on TOF-angiography. Sensitivity for detection of embolic occlusion within major vessel segments (M1, M1/M2, ACA, and PCA) did not show any significant difference between both techniques (97% for SWI versus 96% for TOF-angiography) while the sensitivity for detection of embolic occlusion within M2/M3 was significantly different (84% for SWI versus 39% for TOF-angiography, p<0.00012). SWI and TOF-angiography provide similar sensitivity for central thrombi while SWI is superior for the detection of peripheral thrombi in small arterial vessel segments.

1 November 2012 in Journal of Computational and Applied Mathematics
Verified
Journal Article
Closed access
CZChristian Herbert Ziener
Christian Herbert Ziener
MRM. Rückl
M. Rückl
TKT. Kampf
T. Kampf
WBW.R. Bauer
W.R. Bauer
HSH.P. Schlemmer
H.P. Schlemmer

9 February 2009 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
TWT. Weber
T. Weber
CZChristian Herbert Ziener
Christian Herbert Ziener
TKT. Kampf
T. Kampf
VHV. Herold
V. Herold
WBW. R. Bauer
W. R. Bauer
PJP. M. Jakob
P. M. Jakob
It had been previously shown that an idealized version of the two-wave-vector extension of the NMR pulsed-field-gradient spin echo diffusion experiment can be used to determine the apparent radius of geometries with restricted diffusion. In the present work, the feasibility of the experiment was demonstrated in an NMR imaging experiment, in which the apparent radius of axons in white matter tissue was determined. Moreover, numerical simulations have been carried out to determine the reliability of the results. For small diffusion times, the radius is systematically underestimated. Larger gradient area, finite length gradient pulses, and a statistical distribution of radii within a voxel all have a minor influence on the estimated radius. Magn Reson Med, 2009.