Under corrosive environments, concrete material properties can deteriorate significantly, which can seriously affect structural safety. Therefore, it has important engineering applications to improve the durability performance at a lower economic cost. This paper proposes a new, highly durable concrete using inexpensive construction materials such as basalt fiber, sodium methyl silicate, and inorganic aluminum salt waterproofing agent. With the massive application of sewage treatment projects, the problem of concrete durability degradation is becoming more and more serious. In this paper, five types of concrete are developed for the sewage environment, and the apparent morphology and fine structure of the specimens after corrosion in sewage were analyzed. The density, water absorption, and compressive strength were measured to investigate the deterioration pattern of concrete properties. It was found that ordinary concrete was subject to significant corrosion, generating large deposits of algae on the surface and accompanied by sanding. The new concrete showed superior corrosion resistance compared to conventional concrete. Among other factors, the inorganic aluminum salt waterproofing agent effect was the most prominent. The study found that the strength of ordinary concrete decreased by about 15% in the test environment, while the new concrete had a slight increase. Comprehensive evaluation showed that the combination of basalt fiber and inorganic aluminum salt waterproofing agent had the best effect. Its use is recommended.
To enhance the local buckling resistance of thin-walled steel pipes and enhance their fire and corrosion resistance, a new spirally stiffened thin-walled square concrete-filled steel tubular laminated composite member with transverse ribs is proposed. Through the four forms of combined members for eccentric pressure testing, it was found that: ordinary thin-walled steel pipe concrete drum buckling is more severe; with spiral ribs, the buckling is limited between the stiffening ribs; and the deformation is significantly reduced. By addressing the problem of cooperative work between the inner and outer structural layers of new components, it was found that, after setting constraints such as steel bars, the integrity of the two can be ensured, and the stress performance is significantly improved; compared to ordinary steel pipe concrete, the load-carrying capacity is 17.9% higher, and the deformation capacity is roughly equivalent. Spiral ribs as a new form of spatial restraint, in addition to increasing the local bending stiffness, manifest an overall restraint role in limiting lateral deformation of the steel pipe, whereas the role of vertical stiffness is insignificant. Based on test evidence, the influences of the width to thickness ratio of spiral ribs and pitch were determined, and reasonable structural measures for the members were given. Through the N–M relationship curve, the limit of damage in compression and tension under eccentricity was obtained at an eccentricity of about 0.9. Finally, a method for calculating the eccentric compressive ultimate load capacity of this new composite member was proposed.
The PBL (Perfobond Leiste) shear connector has the advantages of high bearing capacity and strong constraint ability; however, the traditional PBL shear connector has strong and weak axis problems, and its stiffness is large, resulting in weak deformation ability. To this end, this paper proposes a new type of flange triple-web shear key and obtains the new shear key’s mechanical properties and failure mechanism through the push-out test. The results show that the failure mode of the new shear key is the deformation of the steel plate on the web and the edge of the opening, which has a high bearing capacity, outstanding deformation ability, and good integrity with concrete, showing obvious semi-rigid characteristics. Through numerical analysis, the effects of flange width, web height, and steel plate thickness on the mechanical properties of shear keys are obtained. Based on the fitting analysis method, the calculation formula of shear key bearing capacity is proposed. Finally, the horizontal seismic performance of the shear key is numerically simulated. It is found that the hysteretic curve of the shear key is full and shows good energy dissipation capacity.
Thin-walled steel pipe concrete has better economic performance, but the problem of local buckling is more prominent with a thin-walled steel pipe; meanwhile, thin-walled steel pipe is more sensitive to the environment and the influence of rusting is more prominent. To solve the above problems, this paper proposes new spiral stiffened rib thin-walled steel pipe concrete laminated members to obtain better force and economic performance. Based on axial compression tests on five forms of composite members, this paper studies the nonlinear behavior of the axial compression of this new type of laminated member and the factors influencing it. The following conclusions are obtained. Under the constraint of the spiral ribs, the new composite member has good integrity and each part can ensure cooperative stress; the buckling of the steel pipe is well limited and the mechanical performance is significantly improved. Compared with ordinary thin-walled concrete-filled steel tubular members, the bearing capacity is increased by about 20% and the deformation ability is increased by more than 30%. The nonlinear behavior of the member in compression can be better achieved through finite element analysis. The parametric analysis shows that the pitch and the steel tube width-to-thickness ratio greatly influence the force behavior of the member. In contrast, the spiral rib width-to-thickness ratio and the external reinforcement only need to meet the structural requirements. Finally, based on the superposition theory, the proposed method of calculating the member’s axial compressive load-bearing capacity is given and design suggestions are made. The results of this paper can provide some basis for the engineering application of this new combination member.