With the increasing use of electric vehicles (EVs), EVs will be widely connected to the microgrid in the future. However, the influence of the disorderly charging behavior of EVs on the stable and reliable operation of the power grid cannot be ignored. To address these challenges, the charging load characteristic model is established to describe the charging behavior of EVs. Then, an EVs orderly charging strategy based on electricity price guidance is proposed, and the goal is to minimize the peak–valley difference ratio and the total cost of EV charging. The result shows that, compared with disorderly charging, the EV orderly charging strategy based on electricity price guidance proposed in this paper can effectively reduce the peaking and valley difference ratio of load, reduce user’s charging costs, and optimize the reliability level of the microgrid.
The influence of the control strategy of the power electronic converter obscures the fault characteristics of DC distribution networks. The existence of arc faults over an extended period of time poses a grave threat to the security of power grids and may result in electric shock, fire, and other catastrophes. In recent years, the method of fault localization based on the traveling wave method has been a popular topic of research in the field of DC distribution system protection. In this paper, the fault localization principle of the traveling wave method is described in depth, and the propagation characteristics of the traveling wave of fault current in the online mode network are deduced. We present a method for wave head calibration that combines empirical mode decomposition (EMD) and singular value decomposition (VMD). After the fault-traveling current signal has been subjected to EMD, the first eigenmode function is extracted and subjected to singular value decomposition (SVD). After SVD, the detail component can reflect the singularity of the signal. The point of the maximum value of the detail component signal corresponds to the moment when the faulty traveling wave head reaches the monitoring point. Finally, the DC distribution system is modeled based on the PSCAD/EMTDC simulation environment, and the fault location method is verified. The simulation results show that the method can effectively realize fault localization.
High-resistance faults in direct current (DC) microgrids are small and thus difficult to detect. Such faults may be “invisible” in that grid operation continues for a considerable time, which damages the grid. It is essential to detect and remove high-resistance faults; we present a detection method herein. First, the transient DC current during the fault is subjected to hierarchical wavelet decomposition to identify high-resistance faults accurately and sensitively; the wavelet coefficients are detected using the singular value decomposition (SVD) method. The SVD valve can denoise the dc microgrid fault current, which eliminates the influence of converter switching frequency and background noise effectively. Power system computer-aided design (PSCAD)/electromagnetic transients including direct current (EMTDC)-based simulations showed that our method successfully identified high-resistance faults.
The prerequisite for the normal operation of a flexible high-voltage direct current (HVDC) transmission system is the maintenance of the stability of the direct current (DC)-side voltage, and droop control has a good dynamic regulation capability. In this paper, we first study the operating characteristics of droop control and derive its equivalent circuit, as well as the power distribution equation for droop control with a four-terminal system as an example. Then, based on this, an improved droop control method is proposed so that the droop factor can be adaptively adjusted according to the power change and provide corresponding characteristics under different operating conditions to enhance the power regulation capability of the controller under high power fluctuations. Finally, a power systems computer-aided design (PSCAD) electromagnetic transient model of the four-terminal, flexible, high-voltage DC transmission system was established and verified by simulation results.