Jiping Xiong

Prof. Jiping Xiong


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2025 in Electronics
Verified
Journal Article
Open access
PDF file
LHLinying He
Linying He
LZLijuan Zheng
Lijuan Zheng
JXJiping Xiong
Jiping Xiong
Surface defects during steel production can severely impact product quality and safety, making defect detection crucial. To improve the precision and performance of conventional approaches, we introduce FMV-YOLO, a model for detecting steel surface defects, built upon YOLOv11n. First, we substitute the C2PSA attention module in the backbone network with an Adaptive Fine-Grained Channel Attention (FCA) module, which improves defect type identification while reducing the parameter count. Next, we incorporate a new Multi-Scale Attention Fusion module (MSAF) to strengthen feature representation and refine the loss function using Normalized Wasserstein Distance (NWD) loss, thereby improving the localization accuracy of small defects. Finally, we integrate the VoV-GSCSP module within the neck network to achieve lightweighting, facilitating real-world deployment. Extensive experiments on the GC10DET and NEU-DET datasets demonstrate that the model effectively balances detection accuracy, parameter count, and computational load. With 2.6M parameters and 5.7G FLOPs, the model attains an mAP@0.5 of 73.4% on GC10DET and 80.2% on NEU-DET. Additionally, the method achieves 99% detection accuracy on a self-constructed industrial dataset, proving its effectiveness in industrial defect detection.

13 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
HCHanquan Cheng
Hanquan Cheng
JXJiping Xiong
Jiping Xiong
ZCZe Hui Chen
Ze Hui Chen
JCJingwei Chen
Jingwei Chen
In this paper, a multi-stage deep learning blood pressure prediction model based on imaging photoplethysmography (IPPG) signals is proposed to achieve accurate and convenient monitoring of human blood pressure. A camera-based non-contact human IPPG signal acquisition system is designed. The system can perform experimental acquisition under ambient light, effectively reducing the cost of non-contact pulse wave signal acquisition while simplifying the operation process. The first open-source dataset IPPG-BP for IPPG signal and blood pressure data is constructed by this system, and a multi-stage blood pressure estimation model combining a convolutional neural network and bidirectional gated recurrent neural network is designed. The results of the model conform to both BHS and AAMI international standards. Compared with other blood pressure estimation methods, the multi-stage model automatically extracts features through a deep learning network and combines different morphological features of diastolic and systolic waveforms, which reduces the workload while improving accuracy.

6 August 2024 in IEEE Access
Verified
Journal Article
Open access
WCWei Chen
Wei Chen
LZLijuan Zheng
Lijuan Zheng
JXJiping Xiong
Jiping Xiong
Crop diseases and pests cause significant economic losses to agriculture every year, making accurate identification crucial. Traditional pest detection relies on farm experts and is often very time-consuming. Computer vision technology and artificial intelligence can provide automatic disease detection, enabling real-time and precise control of crop diseases and timely prevention. To accurately identify plant diseases under complex natural conditions, an improved crop disease and pest recognition model was established based on the original YOLOv5 network model.First, we integrated the Squeeze-and-Excitation (SE) attention module into YOLOv5, allowing our proposed model to better differentiate leaf features between different crops and accurately identify disease types. Second, to enhance the model’s feature extraction capability for diseased areas and reduce the loss of disease feature information, we replaced the original upsampling operator in YOLOv5 with the lightweight Content-Aware ReAssembly of FEatures (CARAFE) module. Next, we improved the original loss function by adopting the Efficient Intersection over Union (EIoU) loss function to increase detection accuracy. Finally, to reduce the model’s complexity and meet real-time detection requirements, we introduced the Ghost convolution module into the backbone network.During the experimental phase, to validate the model’s effectiveness, we randomly divided sample images from the constructed crop disease and pest database into training, validation, and test sets. The experimental results showed that the improved YOLOv5 model achieved a precision of 90.0%, a recall of 91.4%, an mAP@.50 of 92.1%, and an mAP@.5:.95 of 64%. The number of parameters and computational load were reduced by 23.9% and 31.2%, respectively, outperforming popular methods including YOLOv5, YOLOv7, and YOLOv8.The improved model can accurately identify crop diseases and pests under natural conditions and is conducive to deployment on edge devices, providing a technical reference for crop disease and pest management.

3 March 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JXJiping Xiong
Jiping Xiong
LCLisang Cai
Lisang Cai
FWFei Wang
Fei Wang
XHXiaowei He
Xiaowei He
Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

5 March 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
HFHongli Fang
Hongli Fang
JXJiping Xiong
Jiping Xiong
LHLinying He
Linying He
Hypertension is typically manifested as a latent symptom that requires detection through specialized equipment. This poses an inconvenience for individuals who need to undergo long-term blood pressure monitoring in their daily lives. Therefore, there is a need for a portable, non-contact method for estimating blood pressure. However, current non-contact blood pressure estimation methods often rely on relatively narrow datasets, lacking a broad range of blood pressure distributions. Additionally, their applicability is confined to controlled experimental environments. This study proposes a non-contact blood pressure estimation method suitable for various life scenarios, encompassing multiple age groups, diverse ethnicities, and individuals with different skin tones. The aim is to enhance the practicality and accuracy of existing non-contact blood pressure estimation methods. The research extracts the imaging photoplethysmogram (IPPG) signal from facial videos and processes the signal through four layers of filtering operations to obtain an IPPG signal reflecting pulse wave variations. A CNN+BiLSTM+GRU network structure is constructed to improve the accuracy of current non-contact blood pressure estimation methods. In comparison to existing approaches, the mean absolute error (MAE) for systolic blood pressure (SBP) and diastolic blood pressure (DBP) is reduced by 13.6% and 16.4%, respectively.

10 December 2019 in Mobile Networks and Applications
Verified
Journal Article
Closed access
PDF file
JXJiping Xiong
Jiping Xiong
LYLingfeng Ye
Lingfeng Ye
DJDingde Jiang
Dingde Jiang
TYTong Ye
Tong Ye
FWFei Wang
Fei Wang
LZLingYun Zhu
LingYun Zhu