A novel tunable whispering gallery modes (WGMs) resonator based on a nematic liquid crystal (LC)-filled capillary and magnetic nanoparticles (MNPs)-coated tapered fiber has been proposed and experimentally demonstrated. Thermo-optic tuning of the WGM resonances has been demonstrated by varying optical pump laser power injected into the MNPs-coated fiber half-taper inside the capillary. The tuning mechanism relies on the change of the effective refractive index (RI) of the nematic LC, caused by the photo-thermal effect of MNPs on the surface of the fiber half-taper inducing a temperature change inside the capillary. Tuning of the WGM resonances with sensitivities of 101.5 ± 3.5 pm/mW and 146.5 ± 3.5 pm/mW and tuning ranges of 1.96 nm and 3.28 nm respectively for the two types of liquid crystals (MLC-7012, MDA-05-2782) has been demonstrated. In addition, the relationship between the optical power of the pump laser and the local temperature of the nematic LC was investigated and the heating rate is estimated as 1.49 °C/mW. The proposed thermo-optic tuning scheme has many potential applications in tunable photonic devices and sensors.
A novel micron-range displacement sensor based on a whispering-gallery mode (WGM) microcapillary resonator filled with a nematic liquid crystal (LC) and a magnetic nanoparticle- coated fiber half-taper is proposed and experimentally demonstrated. In the proposed device, the tip of a fiber half-taper coated with a thin layer of magnetic nanoparticles (MNPs) moves inside the LC-filled microcapillary resonator along its axis. The input end of the fiber half-taper is connected to a pump laser source and due to the thermo-optic effect within the MNPs, the fiber tip acts as point heat source increasing the temperature of the LC material in its vicinity. An increase in the LC temperature leads to a decrease in its effective refractive index, which in turn causes spectral shift of the WGM resonances monitored in the transmission spectrum of the coupling fiber. The spectral shift of the WGMs is proportional to the displacement of the MNP-coated tip with respect to the microcapillary’s light coupling point. The sensor’s operation is simulated considering heat transfer in the microcapillary filled with a LC material having a negative thermo-optic coefficient. The simulations are in a good agreement with the WGMs spectral shift observed experimentally. A sensitivity to displacement of 15.44 pm/µm and a response time of 260 ms were demonstrated for the proposed sensor. The device also shows good reversibility and repeatability of response. The proposed micro-displacement sensor has potential applications in micro-manufacturing, precision measurement and medical instruments.
A novel fiber laser structure, to the best of our knowledge, based on an erbium-doped fiber ring (EDFR) and a silica microbottle resonator (MBR) is proposed and investigated experimentally. Two fiber laser samples based on MBRs with different geometries and diameters of 200 and 150 µm are fabricated, and their performance is studied experimentally. Periodic whispering gallery mode spectra of the MBRs are dependent on the position of the fiber taper used for coupling of light into the MBR, and this dependence is explored to achieve lasing at different wavelengths by moving the light coupling point along the axis of the microbottle incorporated into the proposed EDFR-MBR system. The influences of the pump laser power and light polarization on the system performance and laser stability are also investigated. Single-mode lasing with a maximum optical signal-to-noise ratio of 32 dB is demonstrated.
Microfluidic flowmeters are a powerful and highly accurate tool, enabling precise monitoring and measurements of flows of gases and fluids in a range of applications. Here we proposed and experimentally demonstrated a whispering gallery modes flowmeter composed of a liquid crystal-filled nested capillary. Whispering gallery modes are excited by a tapered fiber coupled perpendicularly to the nested capillary. The air flowing through the capillary cools it down, which leads to a temperature-induced change of the refractive index of the nematic liquid crystals. This change in turn leads to a spectral shift of the whispering gallery modes resonances, which can be linked to the airflow rate in the capillary. The temperature change in the liquid crystals was simulated considering the heat transfer between the liquid crystals and airflow in the capillary, which indicated that the liquid crystals temperature decreases in a nonlinear manner with the increase of the airflow rate. A flowmeter with the maximum sensitivity of 0.3423 nm·min·mL−1 in the flowrate range from 0 to 2.52 nm·min·mL−1 and a resolution of 5.72 pm was demonstrated in our experiment. The proposed sensor provides a platform for whispering gallery modes flowmeters and offers the advantages of good stability, high sensitivity, and miniature size.