Zhuo He

Dr. Zhuo He

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2023 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
FFFernando de A. Fernandes
Fernando de A. Fernandes
KLKristoffer Larsen
Kristoffer Larsen
ZHZhuo He
Zhuo He
ENErivelton Nascimento
Erivelton Nascimento
APAmalia Peix
Amalia Peix
CMClaudio T. Mesquita
Claudio T. Mesquita

20 February 2025 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Closed access
PDF file
KLKristoffer Larsen
Kristoffer Larsen
ZHZhuo He
Zhuo He
FFFernando de A Fernandes
Fernando de A Fernandes
XZXinwei Zhang
Xinwei Zhang
CZChen Zhao
Chen Zhao
WZWeihua Zhou
Weihua Zhou

27 May 2020 in medRxiv
Verified
Preprint
Open access
PDF file
CZChen Zhao
Chen Zhao
RBRobert Bober
Robert Bober
HTHaipeng Tang
Haipeng Tang
Jinshan TangJinshan Tang
Jinshan Tang
MDMinghao Dong
Minghao Dong
WZWeihua Zhou
Weihua Zhou
Coronary artery disease (CAD) is the leading cause of death worldwide, constituting more than one-fourth of global mortalities every year. Accurate semantic segmentation of each artery using invasive coronary angiography (ICA) is important for stenosis assessment and CAD diagnosis. However, due to the morphological similarity among different types of arteries, it is challenging for deep-learning-based models to generate semantic segmentation with an end-to-end approach. In this paper, we propose a multi-step semantic segmentation algorithm based on the analysis of arterial segments extracted from ICAs. The proposed algorithm firstly extracts the entire arterial binary mask (binary vascular tree) using a deep learning-based method. Then we extract the centerline of the binary vascular tree and separate it into different arterial segments. Finally, by extracting the underlying arterial topology, position and pixel features, we construct a powerful coronary artery segment classifier based on support vector machine. Each arterial segment is classified into left coronary artery (LCA), left anterior descending (LAD) and other types of arterial segments. We tested the proposed method on a dataset with 225 ICAs and achieved artery classification accuracy of 70.33%. The experimental results show the effectiveness of the proposed algorithm, which provides impressive performance for analyzing the individual arteries in ICAs.

19 September 2025 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Closed access
PDF file
KLKristoffer Larsen
Kristoffer Larsen
CZChen Zhao
Chen Zhao
ZHZhuo He
Zhuo He
JKJoyce Keyak
Joyce Keyak
QSQiuying Sha
Qiuying Sha
WZWeihua Zhou
Weihua Zhou


12 June 2020 in arXiv
Verified
Preprint
Open access
PDF file
HTHaipeng Tang
Haipeng Tang
RBRobert R. Bober
Robert R. Bober
CZChen Zhao
Chen Zhao
CZChaoyang (Joe) Zhang
Chaoyang (Joe) Zhang
HZHuiqing Zhu
Huiqing Zhu
WZWeihua Zhou
Weihua Zhou
Background. Percutaneous coronary intervention(PCI) in stable coronary artery disease(CAD) is commonly triggered by abnormal myocardial perfusion imaging(MPI). However, due to the possibilities of multivessel disease and variability of coronary artery perfusion distribution, opportunity exists to better align anatomic stenosis with perfusion abnormalities to improve revascularization decisions. This study aims to develop a 3D multi-modality fusion approach to assist decision-making for PCI. Methods. Coronary arteries from fluoroscopic angiography(FA) were reconstructed into 3D artery anatomy. Left ventricular(LV) epicardial surface was extracted from SPECT. The 3D artery anatomy was non-rigidly fused with the LV epicardial surface. The accuracy of the 3D fusion was evaluated via both computer simulation and real patient data. For technical validation, simulated FA and MPI were integrated and then compared with the ground truth from a digital phantom. For clinical validation, FA and SPECT images were integrated and then compared with the ground truth from CT angiograms. Results. In the technical evaluation, the distance-based mismatch error between simulated fluoroscopy and phantom arteries is 1.86(SD:1.43)mm for left coronary arteries(LCA) and 2.21(SD:2.50)mm for right coronary arteries(RCA). In the clinical validation, the distance-based mismatch errors between the fluoroscopy and CT arteries were 3.84(SD:3.15)mm for LCA and 5.55(SD:3.64)mm for RCA. The presence of the corresponding fluoroscopy and CT arteries in the AHA 17-segment model agreed well with a Kappa value of 0.91(95% CI: 0.89-0.93) for LCA and 0.80(CI: 0.67-0.92) for RCA. Conclusions. Our fusion approach is technically accurate to assist PCI decision-making and is clinically feasible to be used in the catheterization laboratory. There is an opportunity to improve the decision-making and outcomes of PCI in stable CAD.