Mastering coronary angiography requires practice. Cadavers and animals do not accurately represent the human anatomical body, and practicing with actual patients has medical safety issues. Simulation offers safe and realistic conditions for cardiology intervention training. In this study, we propose a novel 3D printed simulator that contains physically realistic anatomy and has four access points. It increases safety for patients and students, and production is low-cost. We aimed to make and validate this simulator design as a prototype for coronary cannulation training. It was designed using computed tomography (CT) scan data of aorta, coronary, and heart models, and was printed by 3D printing with resin materials consisting of 75% or 85% clear resin and 25% or 15% flexible resin additive. The simulator was constructed with a camera above the simulator with a degree of LAO of 30°/0°, a display table, and an acrylic box. Twelve validators were interviewed for their expert opinions and analyzed by a qualitative method. They scored the simulator’s suitability on a four-point Likert scale questionnaire. They described the simulator as having admirable values for all aspects (85.8%), curriculum suitability (92%), educational importance (94%), accuracy (83%), efficiency (78%), safety (87.5%), endurance (81.2%), aesthetics (80.7%), storage (85.4%), and affordability (85.8%).
30 April 2026 in European Heart Journal - Case Reports
Background: Acute limb ischaemia (ALI) is a potential thromboembolic complication of infective endocarditis (IE), which requires immediate attention to prevent permanent ischaemic injury and loss of limb. Given the complex haemostatic dysregulation inherent to IE, balancing the thrombotic and haemorrhagic risk is critical in its management. Case summary: This study follows a patient diagnosed with ALI Rutherford IIa due to infective endocarditis from Streptococcus sanguinis infection. The patient was successfully treated with percutaneous mechanical thrombectomy using AngioJet®. Angio graphic evaluation showed restored distal arterial flow with no residual thrombus. At follow-up, the patient had returned to their daily activities without complaints. Discussion: ALI secondary to IE is traditionally treated with surgical embolectomy. However, endovascular techniques have emerged as an increasingly preferred first-line therapy, offering comparable clinical efficacy to open surgery alongside enhanced postoperative recovery. To our knowledge, this case represents the first reported use of AngioJet® percutaneous pharmacomechanical thrombectomy for ALI caused by infective endocarditis. Despite the success observed in this particular patient, this approach should remain limited to carefully selected cases until further evidence on its safety and efficacy is available.