Claire Brockett

Dr. Claire Brockett

Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in Wear
Verified
Journal Article
Open access
Claire BrockettClaire Brockett
Claire Brockett
SCSilvia Carbone
Silvia Carbone
JFJohn Fisher
John Fisher
LJLouise M. Jennings
Louise M. Jennings
New bearing materials for total joint replacement have been explored as the need to improve longevity and enhance performance is driven by the changing demands of the patient demographic. Carbon-reinforced PEEK has demonstrated good wear characteristics in experimental wear simulation in both simple geometry pin-on-plate studies and in total hip joint replacement. Carbon reinforced PEEK CFR-PEEK has the potential to reduce tibial insert thickness and preserve bone in the knee.

27 March 2012 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
Claire BrockettClaire Brockett
Claire Brockett
GJGemma John
Gemma John
SWSophie Williams
Sophie Williams
ZJZhongmin Jin
Zhongmin Jin
GIGraham H. Isaac
Graham H. Isaac
JFJohn Fisher
John Fisher

8 November 2007 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
Claire BrockettClaire Brockett
Claire Brockett
PHPhil Harper
Phil Harper
SWSophie Williams
Sophie Williams
GIGraham H. Isaac
Graham H. Isaac
Robert Dwyer-JoyceRobert Dwyer-Joyce
Robert Dwyer-Joyce
JFJohn Fisher
John Fisher

1 October 2016 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
Claire BrockettClaire Brockett
Claire Brockett
SCS. Carbone
S. Carbone
AAA. Abdelgaied
A. Abdelgaied
JFJ. Fisher
J. Fisher
LJL.M. Jennings
L.M. Jennings
Total joint replacement is a successful surgical intervention for the treatment of the degeneration of many joints, particularly the hip and knee. As the demand for joint replacement grows, and the life expectancy of the population increases, the performance requirements of these implants also changes. New materials, to improve longevity and enhance performance have been explored including PEEK and CFR-PEEK. This study investigated whether CFR-PEEK and PEEK were appropriate materials for total joint replacement by examining wear performance in simple configuration studies articulating against cobalt chrome under a range of cross-shear and contact pressure conditions. Simple geometry pin on plate studies were conducted for one million cycles for each test condition, with the contact pressure and cross-shear conditions representing a range in which the material may need to operate in-vivo. The wear factor for PEEK was significantly higher than CFR-PEEK and conventional polyethylene under all test conditions. Both PEEK and CFR-PEEK wear were influenced by contact pressure, with the highest wear factors for both materials measured at the highest pressure conditions. PEEK appeared to have a cross-shear dependent wear response, but this was not observed for the CFR-PEEK material. This study has further characterised the wear performance of two materials that are gaining interest for total joint replacement. The wear performance of the PEEK material showed poorer wear performance compared to polyethylene when articulating with a metal counterface, but the performance of the CFR-PEEK material suggested it may provide a suitable alternative to polyethylene in some applications. The wear performance of CFR-PEEK was poorer than polyethylene when it was used as the plate, when there was translation of the contact zone over the surface of the CFR-PEEK plate. This has implications for applications in low conforming contacts, such as lower conformity knee replacement.

15 April 2011 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
PDF file
Claire BrockettClaire Brockett
Claire Brockett
LJL M Jennings
L M Jennings
JFJ Fisher
J Fisher
Unicompartmental knee replacements (UKR) are an option for surgical intervention for the treatment of single-compartment osteoarthritis. The aim of this study was to compare the wear of a low-conformity fixed-bearing UKR with a conforming mobile bearing UKR under two kinematic conditions, to investigate the effect of implant design and kinematics on wear performance in a physiological knee wear simulator. Under both sets of kinematic conditions, the relatively low-conforming fixed UKR showed lower wear, compared with the more conforming anterior-posterior sliding mobile bearing. However, it should be noted that differences in materials between the two designs also contribute to the relative wear performance of the bearings. The combined wear of the medial and lateral bearings of the fixed-bearing UKR as a ‘total knee’ were significantly reduced compared with a fixed-bearing total knee replacement studied under the same kinematic conditions.

17 December 2017 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
PDF file
Claire BrockettClaire Brockett
Claire Brockett
SCSilvia Carbone
Silvia Carbone
JFJohn Fisher
John Fisher
LJLouise M Jennings
Louise M Jennings
Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this study was to investigate the effect of insert conformity on the wear performance of a fixed bearing total knee replacement through experimental simulation. Two geometries of insert were studied under standard gait conditions. There was a significant reduction in wear with reducing implant conformity. This study has demonstrated that bearing conformity has a significant impact on the wear performance of a fixed bearing total knee replacement, providing opportunities to improve clinical performance through enhanced material and design selection.