Extracellular vesicles are evaluated by nanoparticle tracking analysis (NTA), providing information on their hydrodynamic diameters, and by atomic force microscopy (AFM) to calculate their geometric diameters. The aim of this study is to explore the influence of Brownian movements in a sample drop and preparation time on imaging-based measurements and to determine the relationship between the geometric and hydrodynamic sizes of the extracellular vesicles measured by the AFM and the NTA, respectively. Exosomes derived from the human prostate cancer cell line PC3 were evaluated by NTA and AFM, and those results were compared with Monte Carlo simulations. The mean size, evaluated by AFM shortly after application on the mica substrate, is less than its real value. It obtains the correct value faster for a thinner sample drop. Fitting the log-normal distribution to the geometric and hydrodynamic diameters leads to the conclusion that the latter could arise from the former by linear scaling by a factor that could be used to characterize the analyzed extracellular vesicles. The size of the vesicles attached to the mica substrate depends on time. The effect of Brownian motion and stretch of the lipid bilayer should be considered in the context of exosome AFM studies.
13 September 2022 in Radiation and Environmental Biophysics
Exosomes are spherical membrane nanovesicles secreted from cells, and they play an important role in tumor immune response, metastasis, angiogenesis, and survival. Studies investigating exosomes isolated from cells exposed to photon radiation commonly used in conventional radiotherapy demonstrate the influence of this type of radiation on exosome characteristics and secretion. There is currently no research investigating the effects of densely ionizing particles such as protons and alpha radiation on exosomes. Thus we have evaluated the cellular response of human prostate cancer cells exposed to 0, 2, and 6 Gy of alpha radiation emitted from the Am-241 source. Irradiated PC3 and DU145 cell lines, characterized by differences in radiosensitivity, were studied using apoptosis, LDH, and IL-6 assays. Additionally, the corresponding concentration and size of isolated exosomes were measured using NTA. We found that exposure to ionizing radiation resulted in gross changes in viability and cell damage. There were increased amounts of apoptotic or necrotic cells as a function of radiation dose. We demonstrated that irradiated PC3 cells secrete higher quantities of exosomes compared to DU145 cells. Additionally, we also found no statistical difference in exosome size for control and irradiated cells.
The use of machine learning algorithms (ML) in radiotherapy is becoming increasingly popular. More and more groups are trying to apply ML in predicting the so-called gamma passing rate (GPR). Our team has developed a customized approach of using ML algorithms to predict global GPR for electronic portal imaging device (EPID) verification for dose different 2% and distance to agreement 2 mm criteria for VMAT dynamic plans. Plans will pass if the GPR is greater than 98%. The algorithm was learned and tested on anonymized clinical data from 13 months which resulted in more than 3000 treatment plans. The obtained results of GPR prediction are very interesting. Average specificity of the algorithm based on an ensemble of 50 decision tree regressors is 91.6% for our criteria. As a result, we can reduce the verification process by 50%. The novel approach described by our team can offer a new insight into the application of ML and neural networks in GPR prediction and dosimetry.
23 September 2025 in Radiation Physics and Chemistry
Introduction: Chronic rhinosinusitis in children represents a significant clinical challenge. Imaging-based diagnosis relies primarily on descriptive assessment of computed tomography scans and simplified scoring systems that do not account for the actual volume of inflammatory lesions. A more quantitative analysis of sinus involvement could improve diagnostic accuracy and reduce interobserver variability. Objective: The aim of this study was to develop a machine learning algorithm for the automated quantitative assessment of maxillary sinus volume and inflammatory involvement in children based on computed tomography scans. Materials and methods: The study includes 92 computed tomography scans of the paranasal sinuses obtained from paediatric patients, with the maxillary sinuses manually annotated by human experts. A three-dimensional convolutional neural network was developed for sinus segmentation. Based on the segmentation results, sinus volume and the percentage of sinus involvement by inflammatory changes were calculated. Results: The algorithm demonstrates high segmentation performance, achieving mean sensitivity, precision, and Dice coefficient values of nearly 90%. The root-mean-square error for estimation of sinus volume and inflammatory involvement is 0.4 cm3 and 1.3 percentage points, respectively. Conclusions: The proposed approach enables rapid and precise assessment of maxillary sinus volume and the extent of inflammatory involvement in paediatric computed tomography examinations. It may serve as a valuable tool supporting clinical decision-making in the diagnosis and longitudinal monitoring of chronic rhinosinusitis in children.
1 March 2025 in Polish Journal of Medical Physics And Engineering
Introduction: Radiotherapy using the CyberKnife (CK) system for treating eye tumors requires tracking skull movements and immobilizing the eye. This study aims to develop a custom algorithm for a noninvasive eye position monitoring system in the CK framework. Material and Methods: Retrospective data were analyzed from 13 patients treated with CK over five fractions. Eye immobilization was achieved using two guides above the patient’s head, with a black dot as the fixation eye. Camera recording was used to analyze pupil movements. A Python-based algorithm was developed to calculate eye position angles relative to the desired direction. A Quality Index (QI) was defined as the Common Area (CA) ratio of the 80% isodose and Planning Target Area (PTA) to the isodose area shifted by eye movement. For simplicity, only horizontal eye movement (angle φ) was considered. Dose distribution and CT data were processed in ImageJ, and a script calculated CA values for all integer φ angles. MediaPipe was used to map facial landmarks, estimate iris contours, and track pupil center positions on the XY plane. Results: The algorithm analyzed camera recording during fractions of radiation, issuing visual and auditory warnings when gaze angles exceeded 20°. Instantaneous and average QI values were also monitored, with violations prompting controlled therapy interruptions. Analysis of 7 patients showed effective eye tracking. Two patients struggled to maintain their gaze, leading to frequent warnings. For six recordings, issues arose due to missing facial landmarks, 90° image rotations, or partially closed eyes. Conclusion: The custom algorithm provides real-time eye movement analysis and can enhance treatment quality monitoring in CK-based eye tumor therapy.