Rushan Xie

Ms. Rushan Xie

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2017 in Toxins
Verified
Journal Article
Open access
PDF file
XFXiaoxiang Fu
Xiaoxiang Fu
RXRushan Xie
Rushan Xie
JWJian Wang
Jian Wang
XCXiaojiao Chen
Xiaojiao Chen
XWXiaohan Wang
Xiaohan Wang
BWBaomin Wang
Baomin Wang
Rice false smut is a worldwide devastating rice disease infected by the fungal pathogen Villosiclava virens. Ustiloxin A (UA) and ustiloxin B (UB), cyclopeptide mycotoxins, were the major ustiloxins isolated from the rice false smut balls (FSBs) that formed in the pathogen‐infected rice spikelets. Based on the specific monoclonal antibodies (mAbs) 2D3G5 and 1B5A10, respectively, against UA and UB, the lateral flow immunoassays (LFIAs) were developed, and the indicator ranges for UA and UB both were 50-100 ng/mL. The cross‐reactivities of UB for UA LFIA, and UA for UB LFIA were 5% and 20%, respectively, which were consistent with the icELISA results reported previously. Even at 50,000 ng/mL, none of other commonly existent metabolites in rice samples caused noticeable inhibition. The LFIAs were used for determination of UA and UB contents in rice FSBs and rice grains, and the results were agreeable with those by HPLC and icELISA. There was no change in the sensitivity of either dipstick stored at 4 °C) after at least three months. The developed LFIA has specificity and sensitivity for detecting UA and UB as well as simplicity to use. It will be a potential point‐of‐care device for rapid evaluation of the rice samples contaminated by UA and UB.

6 September 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
ZRZiming Ren
Ziming Ren
SYShijie Yang
Shijie Yang
RXRushan Xie
Rushan Xie
Zhonggang ZhangZhonggang Zhang
Zhonggang Zhang
LGLibo Gao
Libo Gao
CXChenyang Xue
Chenyang Xue
The cilium avoids energy loss due to bending deformation during vibration, thereby efficiently transmitting the acoustic driving force to the cross-beam. Meanwhile, a hollow cylindrical structure is adopted instead of the traditional solid one. While maintaining the same external geometry, this hollow design not only increases the effective acoustic area to enhance the acoustic driving force but also reduces the added mass of the cilium. This material–structure synergistic optimization improves the acoustic-to-mechanical transfer efficiency of the cilium in low-frequency acoustic fields, thus enhancing the device’s acoustic sensitivity in the low-frequency range. Parametric simulations are conducted using the COMSOL Multiphysics 6.3 platform to systematically optimize key geometric parameters such as the outer radius and height of the quartz cilium, and the optimal dimensions are determined. The sensitivity and directivity of the prototype are measured in the 20–1000 Hz frequency range using the standard hydrophone comparison method. Experimental results show that the quartz cilium vector hydrophone achieves a sensitivity of –179.1 dB (1 kHz, 0 dB = 1 V/μPa) at 1000 Hz. The frequency response curve exhibits good flatness in the low-frequency range and agrees well with the theoretical 6 dB per octave increase characteristic of pressure gradient sensors. Directivity tests reveal a typical figure-8 pattern at both 315 Hz and 630 Hz, with null depths exceeding 30 dB, demonstrating excellent vector detection capability. This study provides an effective approach for improving the low-frequency sensitivity of MEMS (Micro-Electromechanical System) vector hydrophones, and the designed device meets the requirements for underwater target detection with promising prospects for engineering applications.