Based on the road surface (bridge deck) temperature, relative humidity, air temperature, wind speed and precipitation observed at two road surface meteorological stations and two bridge deck meteorological stations, as well as subsurface temperature at different depths observed at Hefei meteorological station, the independent variables are selected to establish the relationship between these factors and road surface temperature, using random forest and stepwise regression. The performance of these two methods was compared, and the importance of each factor was analyzed. Results show that the road surface (bridge deck) temperature linearly correlates with air temperature. In the case of low air temperature conditions (air temperature ≤ 8 °C), the road surface temperature is mainly higher than air temperature observed at the same station, and the bridge deck temperature is mainly lower than air temperature. In the retrieving of road surface temperature and bridge deck temperature, the random forest algorithm has lower mean absolute error (MAE) and root mean square error (RMSE) than the stepwise regression algorithm, especially in the retrieving of road surface temperature. MAE of road surface temperature retrieved by random forest on two bridge deck stations is reduced by 0.19 °C and 0.26 °C compared with the stepwise regression, and RMSE is reduced by 0.33 °C and 0.49 °C, respectively. The bias in the retrievals can be originated from the model itself and the error in the observations. Among the factors in the random forest model, air temperature is the most important. Meanwhile, there are differences in the importance of each factor in the retrieval of road surface temperature and bridge deck temperature. The subsurface temperature is more important in retrieving road surface temperature, while humidity and wind speed are generally more important to bridge deck temperature. It should be noted that due to the limitation of the observations, this study did not consider the net radiative flux, and the influence of net radiative flux on bridge deck and road surface temperature may be different.
In the process of tower photothermal power generation, solar radiation undergoes the attenuation of the whole atmosphere, reaches the heliostat and then is reflected to the heat collector. The transfer of solar radiation from the heliostat to the heat collector occurs at an altitude of 0 to 300m from the ground, which is defined to be the near-surface layer in this study and is concentrated with high aerosol loadings. Thus, the extinction effects of near-surface aerosols are crucial in the site selection of photothermal power generation and in the evaluation of photothermal power generation efficiency.In this work, we first analyzed the vertical distribution of near-surface aerosol extinction over North China (NC) and its correlation with meteorological factors. CALIOP (Cloud-Aerosol Lidar with Orthogonal Polarization) is a satellite-borne lidar instrument aboard CALIPSO satellite, which provide globally aerosol vertical profiles with unprecedented coverage and spatial resolution. To circumvent data scarcity of longer-term in situ surface measurement of aerosol vertical profiles over the NC region, here CALIOP Level 2 version 4.1 aerosol profile product at 532 nm from January 2019 to December 2019 were adopted. The screened daytime CALIOP L2 data over the NC region were assigned and aggregated into horizontal grids with a resolution of 0.5°×0.5°. The vertical distribution of aerosol extinction coefficient reveals that in winter, Spring and autumn, the aerosol extinction values from near surface to about 1.5km are significantly higher than that above 1.5km. Especially in winter, high aerosol extinction values are found below 1km, indicating weak vertical mixing in winter. The relatively constant aerosol extinction values from near surface to above 2km indicates a higher well-mixed planetary boundary layer (pbl) height in summer. Aerosol extinction between 0-300m accounts for 32%, 17%, 9% and 20% of the aerosol extinction of the whole atmosphere in winter, spring, summer and autumn separately. PM2.5 concentration and surface relative humidity are positively correlated with near-surface aerosol extinction (r=0.4 and 0.31 respectively). Meanwhile, surface visibility is negatively related to the near-surface aerosol extinction (r=-0.45).Then the aerosol extinction coefficient in the near-surface layer was adopted in the SMARTS model and we simulated the radiation transfer between 0 to 300m under different weather conditions. Simulation results of SMARTS model considered near-surface aerosol extinction are closer to radiation observations of a 325m meteorological tower in Beijing than the results of the original SMARTS model under all typical weather conditions.Knowledge of the attenuation of aerosol to solar radiation from the heliostat to the heat collector in the process of tower photothermal power generation is of critical economic importance for the site selection of power station and the evaluation of power generation efficiency.