Andrea Corna

Dr. Andrea Corna


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ASAlexantrou Serb
Alexantrou Serb
ACAndrea Corna
Andrea Corna
RGRichard George
Richard George
AKAli Khiat
Ali Khiat
FRFederico Rocchi
Federico Rocchi
Themis ProdromakisThemis Prodromakis
Themis Prodromakis
Brain function relies on circuits of spiking neurons with synapses playing the key role of merging transmission with memory storage and processing. Electronics has made important advances to emulate neurons and synapses and brain-computer interfacing concepts that interlink brain and brain-inspired devices are beginning to materialise. We report on memristive links between brain and silicon spiking neurons that emulate transmission and plasticity properties of real synapses. A memristor paired with a metal-thin film titanium oxide microelectrode connects a silicon neuron to a neuron of the rat hippocampus. Memristive plasticity accounts for modulation of connection strength, while transmission is mediated by weighted stimuli through the thin film oxide leading to responses that resemble excitatory postsynaptic potentials. The reverse brain-to-silicon link is established through a microelectrode-memristor pair. On these bases, we demonstrate a three-neuron brain-silicon network where memristive synapses undergo long-term potentiation or depression driven by neuronal firing rates.

22 December 2022 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
HSHelen Steins
Helen Steins
MMMichael Mierzejewski
Michael Mierzejewski
LBLisa Brauns
Lisa Brauns
ASAngelika Stumpf
Angelika Stumpf
AKAlina Kohler
Alina Kohler
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz
Recording neural signals from delicate autonomic nerves is a challenging task that requires the development of a low-invasive neural interface with highly selective, micrometer-sized electrodes. This paper reports on the development of a three-dimensional (3D) protruding thin-film microelectrode array (MEA), which is intended to be used for recording low-amplitude neural signals from pelvic nervous structures by penetrating the nerves transversely to reduce the distance to the axons. Cylindrical gold pillars (Ø 20 or 50 µm, ~60 µm height) were fabricated on a micromachined polyimide substrate in an electroplating process. Their sidewalls were insulated with parylene C, and their tips were optionally modified by wet etching and/or the application of a titanium nitride (TiN) coating. The microelectrodes modified by these combined techniques exhibited low impedances (~7 kΩ at 1 kHz for Ø 50 µm microelectrode with the exposed surface area of ~5000 µm²) and low intrinsic noise levels. Their functionalities were evaluated in an ex vivo pilot study with mouse retinae, in which spontaneous neuronal spikes were recorded with amplitudes of up to 66 µV. This novel process strategy for fabricating flexible, 3D neural interfaces with low-impedance microelectrodes has the potential to selectively record neural signals from not only delicate structures such as retinal cells but also autonomic nerves with improved signal quality to study neural circuits and develop stimulation strategies in bioelectronic medicine, e.g., for the control of vital digestive functions.

21 April 2020 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
JWJenny Wickham
Jenny Wickham
ACAndrea Corna
Andrea Corna
NSNiklas Schwarz
Niklas Schwarz
BUBetül Uysal
Betül Uysal
NLNikolas Layer
Nikolas Layer
GZGünther Zeck
Günther Zeck
Human cerebrospinal fluid (hCSF) has proven advantageous over conventional medium for culturing both rodent and human brain tissue. In addition, increased activity and synchrony, closer to the dynamic states exclusively recorded in vivo, were reported in rodent slices and cell cultures switching from artificial cerebrospinal fluid (aCSF) to hCSF. This indicates that hCSF possesses properties that are not matched by the aCSF, which is generally used for most electrophysiological recordings. To evaluate the possible significance of using hCSF as an electrophysiological recording medium, also for human brain tissue, we compared the network and single-cell firing properties of human brain slice cultures during perfusion with hCSF and aCSF. For measuring the overall activity from a majority of neurons within neocortical and hippocampal human slices, we used a microelectrode array (MEA) recording technique with 252 electrodes covering an area of 3.2 × 3.2 mm2. A second CMOS-based MEA with 4225 sensors on a 2 × 2 mm2 area was used for detailed mapping of action potential waveforms and cell identification. We found that hCSF increased the number of active electrodes and neurons and the firing rate of the neurons in the slices and induced an increase in the numbers of single channel and population bursts. Interestingly, not only an increase in the overall activity in the slices was observed, but a reconfiguration of the network could also be detected with specific activation and inactivation of subpopulations of neuronal ensembles. In conclusion, hCSF is an important component to consider for future human brain slice studies, especially for experiments designed to mimic parts of physiology and disease observed in vivo.

6 June 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
ACAndrea Corna
Andrea Corna
THThoralf Herrmann
Thoralf Herrmann
GZGuenther Zeck
Guenther Zeck
Objective . Retinal prostheses have shown promising results in restoring some visual perception to blind patients but successful identification of objects of different size remains a challenge. Here we investigated electrode-size specific stimulation thresholds and their variability for subretinal electrical stimulation. Our findings indicate the range of charge densities required to achieve identification of small objects and the object—size-specific scaling of stimulation threshold. Approach . Using biphasic voltage—limited current stimuli provided by a light-sensitive microchip, we determined threshold charge densities for stimulation with variable electrode sizes. The stimulated activation of the retinal network was identified by recording the spiking of retinal ganglion cells in photoreceptor-degenerated mouse rd10 retinas. Stimulation thresholds were determined for cells with saturating stimulus response relationships (SRRs) but not for cells characterized by monotonically increasing or decreasing SRRs. Main results . Stimulation thresholds estimated in rd10 retinas ranged between 100–900 µ C cm −2 for stimulation with small electrodes (30 µ m diameter). Threshold charge density decreased with increasing electrode size and plateaued at 20 µ C cm −2 for an electrode diameter larger than 300 µ m. This trend of decreasing threshold down to a plateau value was confirmed in wild-type mouse retina suggesting an underlying physiological source. Significance . Our results suggest the following guidelines for retinal prosthetics employing biphasic current pulses. The encoding of small objects may be achieved through the activation of a confined set of different retinal ganglion cells, with individual stimulation thresholds spanning a wide range of charge densities. The encoding of increasing object sizes may be achieved by decreasing stimulation charge density.

17 June 2021 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
ACAndrea Corna
Andrea Corna
PRPoornima Ramesh
Poornima Ramesh
FJFlorian Jetter
Florian Jetter
MLMeng-Jung Lee
Meng-Jung Lee
JMJakob Macke
Jakob Macke
GZGuenther Zeck
Guenther Zeck
Objective. Most neuroprosthetic implants employ pulsatile square-wave electrical stimuli, which are significantly different from physiological inter-neuronal communication. In case of retinal neuroprosthetics, which use a certain type of pulsatile stimuli, reliable object and contrast discrimination by implanted blind patients remained challenging. Here we investigated to what extent simple objects can be discriminated from the output of retinal ganglion cells (RGCs) upon sinusoidal stimulation. Approach. Spatially confined objects were formed by different combinations of 1024 stimulating microelectrodes. The RGC activity in the ex vivo retina of photoreceptor-degenerated mouse, of healthy mouse or of primate was recorded simultaneously using an interleaved recording microelectrode array implemented in a CMOS-based chip. Main results. We report that application of sinusoidal electrical stimuli (40 Hz) in epiretinal configuration instantaneously and reliably modulates the RGC activity in spatially confined areas at low stimulation threshold charge densities (40 nC mm−2). Classification of overlapping but spatially displaced objects (1° separation) was achieved by distinct spiking activity of selected RGCs. A classifier (regularized logistic regression) discriminated spatially displaced objects (size: 5.5° or 3.5°) with high accuracy (90% or 62%). Stimulation with low artificial contrast (10%) encoded by different stimulus amplitudes generated RGC activity, which was classified with an accuracy of 80% for large objects (5.5°). Significance. We conclude that time-continuous smooth-wave stimulation provides robust, localized neuronal activation in photoreceptor-degenerated retina, which may enable future artificial vision at high temporal, spatial and contrast resolution.

Verified
Journal Article
Open access
PDF file
ACAna Cetkovic
Ana Cetkovic
ABAlessandro Bellapianta
Alessandro Bellapianta
MIMihai Irimia-Vladu
Mihai Irimia-Vladu
JHJakob Hofinger
Jakob Hofinger
CYCigdem Yumusak
Cigdem Yumusak
Ahmad SaltiAhmad Salti
Ahmad Salti
Millions of people worldwide are diagnosed with retinal dystrophies such as retinitis pigmentosa and age-related macular degeneration. A retinal prosthesis using organic photovoltaic (OPV) semiconductors is a promising therapeutic device to restore vision to patients at the late onset of the disease. However, an appropriate cytotoxicity approach has to be employed on the OPV materials before using them as retinal implants. In this study, we followed ISO standards to assess the cytotoxicity of D18, Y6, PFN-Br and PDIN individually, and as mixtures of D18/Y6, D18/Y6/PFN-Br and D18/Y6/PDIN. These materials were proven for their high performance as organic solar cells. Human RPE cells were put in direct and indirect contact with these materials to analyze their cytotoxicity by the MTT assay, apoptosis by flow cytometry, and measurements of cell morphology and proliferation by immunofluorescence. We also assessed electrophysiological recordings on mouse retinal explants via microelectrode arrays (MEAs) coated with D18/Y6. In contrast to PFN-Br and PDIN, all in vitro experiments show no cytotoxicity of D18 and Y6 alone or as a D18/Y6 mixture. We conclude that D18/Y6 is safe to be subsequently investigated as a retinal prosthesis.