Chih-Hao Chen

Dr. Chih-Hao Chen


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2021 in Nutrients
Verified
Journal Article
Open access
PDF file
YCYung-Jiun Chien
Yung-Jiun Chien
Chun-Yu ChangChun-Yu Chang
Chun-Yu Chang
Meng-Yu WuMeng-Yu Wu
Meng-Yu Wu
CCChih-Hao Chen
Chih-Hao Chen
YHYi-Shiung Horng
Yi-Shiung Horng
HWHsin-Chi Wu
Hsin-Chi Wu
The therapeutic effects of curcumin for polycystic ovary syndrome (PCOS) remain inconclusive. The present study aims to evaluate the effects of curcumin on glycemic control and lipid profile in patients with PCOS. PubMed, Embase, Scopus, Web of Science, and Cochrane Library were searched from the inception through 28 November 2020. Randomized control trials (RCTs), which enrolled adult patients with PCOS, compared curcumin with placebo regarding the glycemic control and lipid profile, and reported sufficient information for performing meta-analysis, were included. Three RCTs were included. Curcumin significantly improves fasting glucose (mean difference (MD): −2.77, 95% confidence interval (CI): −4.16 to −1.38), fasting insulin (MD: −1.33, 95% CI: −2.18 to −0.49), Homeostasis Model Assessment of Insulin Resistance (HOMA-IR) (MD: −0.32, 95% CI: −0.52 to −0.12), and quantitative insulin sensitivity check index (QUICKI) (MD: 0.010, 95% CI: 0.003–0.018). It also significantly improves high-density lipoprotein (MD: 1.92, 95% CI: 0.33–3.51) and total cholesterol (MD: −12.45, 95% CI: −22.05 to −2.85). In contrast, there is no statistically significant difference in the improvement in low-density lipoprotein (MD: −6.02, 95% CI: −26.66 to 14.62) and triglyceride (MD: 8.22, 95% CI: −26.10 to 42.53) between curcumin and placebo. The results of the fasting glucose, fasting insulin, HOMA-IR, QUICKI, and total cholesterol are conclusive as indicated by the trial sequential analysis. Curcumin may improve glycemic control and lipid metabolism in patients with PCOS and metabolic abnormality without significant adverse effects. Further studies are advocated to investigate the potential effects of curcumin on hyperandrogenism.

13 September 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
CCChih-Hao Chen
Chih-Hao Chen
HLHeng-Yu Haley Lin
Heng-Yu Haley Lin
MWMao-Che Wang
Mao-Che Wang
YCYuan-chia Chu
Yuan-chia Chu
Chun-Yu ChangChun-Yu Chang
Chun-Yu Chang
YCYen-Fu Cheng
Yen-Fu Cheng
Background: Hearing loss is one of the most common disabilities worldwide and affects both individual and public health. Pure tone audiometry (PTA) is the gold standard for hearing assessment, but it is often not available in many settings, given its high cost and demand for human resources. Smartphone-based audiometry may be equally effective and can improve access to adequate hearing evaluations. Objective: The aim of this systematic review is to synthesize the current evidence of the role of smartphone-based audiometry in hearing assessments and further explore the factors that influence its diagnostic accuracy. Methods: Five databases—PubMed, Embase, Cochrane Library, Web of Science, and Scopus—were queried to identify original studies that examined the diagnostic accuracy of hearing loss measurement using smartphone-based devices with conventional PTA as a reference test. A bivariate random-effects meta-analysis was performed to estimate the pooled sensitivity and specificity. The factors associated with diagnostic accuracy were identified using a bivariate meta-regression model. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Results: In all, 25 studies with a total of 4470 patients were included in the meta-analysis. The overall sensitivity, specificity, and area under the receiver operating characteristic curve for smartphone-based audiometry were 89% (95% CI 83%-93%), 93% (95% CI 87%-97%), and 0.96 (95% CI 0.93-0.97), respectively; the corresponding values for the smartphone-based speech recognition test were 91% (95% CI 86%-94%), 88% (95% CI 75%-94%), and 0.93 (95% CI 0.90-0.95), respectively. Meta-regression analysis revealed that patient age, equipment used, and the presence of soundproof booths were significantly related to diagnostic accuracy. Conclusions: We have presented comprehensive evidence regarding the effectiveness of smartphone-based tests in diagnosing hearing loss. Smartphone-based audiometry may serve as an accurate and accessible approach to hearing evaluations, especially in settings where conventional PTA is unavailable.

24 December 2022 in eClinicalMedicine
Verified
Journal Article
Open access
CCChun-Yu Chang
Chun-Yu Chang
YTYu-Kang Tu
Yu-Kang Tu
MKMing-Chang Kao
Ming-Chang Kao
PSPing-Cheng Shih
Ping-Cheng Shih
ISI-Min Su
I-Min Su
CCChu-Ting Chen
Chu-Ting Chen
Post-caesarean section analgesia is important physiologically and psychologically for both mothers and infants. Patient-controlled analgesia is a well-established method of administering opioids for postoperative pain. However, to date, no study has systematically investigated the effects of opioids administered through intravenous patient-controlled analgesia (IVPCA) or patient-controlled epidural analgesia (PCEA) in parturients who have undergone caesarean section. This systematic review and network meta-analysis aimed to evaluate the analgesic and adverse effects of opioids administered via IVPCA or PCEA in parturients who have undergone a caesarean section. PubMed, Embase, Scopus, Web of Science, and Cochrane Library were searched from inception through 02 10, 2022 for relevant records. Randomised controlled trials (RCTs) that compared opioids administered via IVPCA or PCEA and reported outcomes of interest were included. Studies were excluded if the solution for patient-controlled analgesia contained antiemetics and/or other analgesics in addition to opioids. The methodological quality of RCTs was assessed using the revised Cochrane Risk of Bias Tool. Summary data were extracted from each eligible study. The primary outcome was pain intensity, and the secondary outcomes were opioid-related adverse effects. Frequentist network meta-analyses were performed using a contrast-based random-effects model. This study is registered with PROSPERO, CRD42021254040. Twenty-three studies with 2589 parturients were included. Compared with IVPCA morphine as a reference treatment, PCEA fentanyl had better analgesic effects at 4 h (mean difference [MD] in the visual analogue scale score, -0.75; 95% confidence interval [CI] [-1.16, -0.34]) and 8 h (MD, -0.93; 95% CI [-1.57, -0.28]) and yielded lower odds of developing nausea/vomiting (odds ratio [OR], 0.27; 95% CI [0.09, 0.80]) and sedation/drowsiness (OR, 0.22; 95% CI [0.11, 0.45]). However, PCEA fentanyl may be more likely to cause pruritus than IVPCA treatments. Considering the analgesic efficacy; opioid-induced nausea, vomiting, and sedation; and the well-being of breastfed infants, PCEA fentanyl may be the treatment of choice for post-caesarean section analgesia. The Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation (TCRD-TPE-111-27).

CHChii-Yuan Huang
Chii-Yuan Huang
DLDian-Sian Li
Dian-Sian Li
MTMing-Hsien Tsai
Ming-Hsien Tsai
CCChih-Hao Chen
Chih-Hao Chen
YCYen-Fu Cheng
Yen-Fu Cheng
This study investigates the relationship between listening effort and acute tinnitus over the clinical course of sudden sensorineural hearing loss (SSNHL) before and after treatment. Thirty SSNHL patients with acute tinnitus were enrolled in this prospective study. Each patient was evaluated before treatment and after 1 and 3 months of follow-up. Listening effort was evaluated in the unaffected ears in two conditions (with and without background noise) using a dual-task paradigm, which included a primary (speech recognition) task and a secondary (visual reaction time) task. Tinnitus severity was assessed with the Tinnitus Handicap Inventory (THI). It was observed that background noise significantly increased listening effort in SSNHL patients with acute tinnitus before and after treatment. THI scores and listening effort in quiet conditions (** p = 0.009) were significantly decreased three months after treatment. In an analysis of the relation between tinnitus severity and listening effort, it was found that the THI total score was significantly correlated with listening effort in quiet (* p = 0.0388) and noisy conditions (* p = 0.044) before treatment. We concluded that SSNHL patients with acute tinnitus exerted greater listening effort in the presence of background noise than in quiet conditions. Furthermore, listening effort was reduced as tinnitus improved in SSNHL patients during the three months after treatment. Both before and after 3 months of treatment, patients who were more affected and emotionally distressed by tinnitus tended to exert more listening effort in both quiet and noisy environments.

13 April 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
CCChih-Hao Chen
Chih-Hao Chen
CHChii-Yuan Huang
Chii-Yuan Huang
HCHsiu-Lien Cheng
Hsiu-Lien Cheng
HLHeng-Yu Haley Lin
Heng-Yu Haley Lin
YCYuan-chia Chu
Yuan-chia Chu
YCYen-Fu Cheng
Yen-Fu Cheng
Traditional otoscopy has some limitations, including poor visualization and inadequate time for evaluation in suboptimal environments. Smartphone-enabled otoscopy may improve examination quality and serve as a potential diagnostic tool for middle ear diseases using a telemedicine approach. The main objectives are to compare the correctness of smartphone-enabled otoscopy and traditional otoscopy and to evaluate the diagnostic confidence of the examiner via meta-analysis. From inception through 20 January 2022, the Cochrane Library, PubMed, EMBASE, Web of Science, and Scopus databases were searched. Studies comparing smartphone-enabled otoscopy with traditional otoscopy regarding the outcome of interest were eligible. The relative risk (RR) for the rate of correctness in diagnosing ear conditions and the standardized mean difference (SMD) in diagnostic confidence were extracted. Sensitivity analysis and trial sequential analyses (TSAs) were conducted to further examine the pooled results. Study quality was evaluated by using the revised Cochrane risk of bias tool 2. Consequently, a total of 1840 examinees were divided into the smartphone-enabled otoscopy group and the traditional otoscopy group. Overall, the pooled result showed that smartphone-enabled otoscopy was associated with higher correctness than traditional otoscopy (RR, 1.26; 95% CI, 1.06 to 1.51; p = 0.01; I2 = 70.0%). Consistently significant associations were also observed in the analysis after excluding the simulation study (RR, 1.10; 95% CI, 1.00 to 1.21; p = 0.04; I2 = 0%) and normal ear conditions (RR, 1.18; 95% CI, 1.01 to 1.40; p = 0.04; I2 = 65.0%). For the confidence of examiners using both otoscopy methods, the pooled result was nonsignificant between the smartphone-enabled otoscopy and traditional otoscopy groups (SMD, 0.08; 95% CI, -0.24 to 0.40; p = 0.61; I2 = 16.3%). In conclusion, smartphone-enabled otoscopy was associated with a higher rate of correctness in the detection of middle ear diseases, and in patients with otologic complaints, the use of smartphone-enabled otoscopy may be considered. More large-scale studies should be performed to consolidate the results.

2 December 2020 in Brain Sciences
Verified
Journal Article
Open access
PDF file
CCChih-Hao Chen
Chih-Hao Chen
CHChii-Yuan Huang
Chii-Yuan Huang
Chun-Yu ChangChun-Yu Chang
Chun-Yu Chang
YCYen-Fu Cheng
Yen-Fu Cheng
Study Objective: Tinnitus is a common disorder characterized by sound in the ear in the absence of external or internal stimuli. Low-level laser therapy (LLLT) was discovered enhancing tissue repair via increasing the blood microcirculation and cell proliferation in 1960s. In the last two decades, LLLT delivered to the cochlea has frequently been used to reduce the severity of tinnitus. However, whether LLLT effectively attenuates the severity of tinnitus remains controversial. We aimed to evaluate the efficacy of low-level laser therapy on adult patients with complaints of tinnitus. Design: Systematic review and meta-analysis with trial sequential analysis. Interventions: Low-level laser therapy (LLLT). Measurements: Tinnitus Handicap Inventory (THI) score; improvement rates of the visual analog scale (VAS), verbal rating scale (VRS) and numeric rating scale (NRS) scores. Methods: We searched PubMed, Embase, Scopus, Web of Science, and the Cochrane Library from inception through 17 September 2020. Randomized control trials that involved adult patients with complaints of tinnitus, compared LLLT to a placebo and provided sufficient information for meta-analysis were considered eligible. Main Results: Overall, 11 studies involving 670 patients were included. No significant difference in the overall effect according to the THI score (mean difference (MD), −2.85; 95% CI, −8.99 to 3.28; p = 0.362; I2 = 0%) and the rating scale score improvement rate (risk ratio (RR), 1.35; 95% CI, 0.81 to 2.27; p = 0.250; I2 = 67%) was demonstrated between patients receiving LLLT and those receiving a placebo. None of the subgroup analyses showed significant differences, regardless of underlying sensorineural hearing loss, the number of irradiation sessions or the wavelength used. Conclusions: Our meta-analysis suggests that the value of LLLT in controlling the severity of tinnitus remains unclear, in part due to the relatively small number of patients and underlying heterogeneity. More large-scale investigations of LLLT for tinnitus related to inner ear disease are required to further elucidate the therapeutic effects.