The use of field deployable fluorescence sensors by the U.S. Geological Survey has become increasingly common for a wide variety of surface water and groundwater investigations. This report addresses field deployable fluorometers that measure the fluorescence response of various substances in water exposed to incident light generated by the sensor. An introduction to the basic principles of field measurements of fluorescence is provided, as well as technical background information on sensors that target dissolved organic matter, wastewater, and hydrocarbons, including sensor selection, operating principles, key features, and design elements. General deployment, operation and maintenance protocols, quality-assurance techniques, and suggestions for data reporting are presented to facilitate and standardize the collection and accurate communication of data collected by the U.S. Geological Survey across studies, sites, and sensor types. Sensor performance issues and common interferences are also described. An appendix is included to describe sensor calibration criteria and procedures, reporting units, and specific approaches to correct for interferences for fluorescence of dissolved organic matter sensors.
The use of algal fluorometers by the U.S. Geological Survey (USGS) has become increasingly common. The basic principles of algal fluorescence, instrument calibration, interferences, data quantification, data interpretation, and quality control are given in Hambrook Berkman and Canova (2007). Much of the guidance given for instrument maintenance, data storage, and quality assurance in Wagner and others (2006) are also applicable to algal fluorometers, although they are not explicitly discussed. Algal fluorometers have advanced substantially since these guidance documents were published; so that while the basic principles remain unchanged, new guidance is needed. This techniques and methods report is intended to provide additional information on algal fluorescence-sensor calibration, maintenance, measurement, data storage, and quality assurance that meet stated objectives of USGS data-collection efforts. The operations described facilitate and standardize the collection and accurate communication of algal fluorescence data collected by the USGS across studies, sites, and instrument types. This report provides technical background information on algal fluorescence sensors; including specifications, operating principles, key features, and design elements. Maintenance and calibration protocols, quality-assurance techniques, and suggestions for data reporting are presented. Sensor performance issues, common interferences, and strategies for addressing them are also described.
2 December 2021 in River Research and Applications
Water temperature is an important factor influencing the migration, rearing, and spawning of several important fish species in rivers of the Pacific Northwest. To protect these fish populations and to fulfill its responsibilities under the Federal Clean Water Act, the Oregon Department of Environmental Quality set a water temperature Total Maximum Daily Load (TMDL) in 2006 for the Willamette River and the lower reaches of its largest tributaries in northwestern Oregon. As a result, the thermal discharges of the largest point sources of heat to the Willamette River now are limited at certain times of the year, riparian vegetation has been targeted for restoration, and upstream dams are recognized as important influences on downstream temperatures. Many of the prescribed point-source heat-load allocations are sufficiently restrictive that management agencies may need to expend considerable resources to meet those allocations.