Xuefei Mao

Prof. Xuefei Mao


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
LZLiuquan Zhang
Liuquan Zhang
HSHuaxin Song
Huaxin Song
YGYanbin Guo
Yanbin Guo
BFBei Fan
Bei Fan
YHYatao Huang
Yatao Huang
BLBaiyi Lu
Baiyi Lu

15 December 2015 in Journal of Agricultural and Food Chemistry
Verified
Journal Article
Closed access
YHYatao Huang
Yatao Huang
MWMin Wang
Min Wang
XMXuefei Mao
Xuefei Mao
YQYongzhong Qian
Yongzhong Qian
TCTianjin Chen
Tianjin Chen
YZYing Zhang
Ying Zhang

4 January 2016 in The Analyst
Verified
Journal Article
Closed access
PDF file
YWYuelong Wang
Yuelong Wang
LLLingling Lin
Lingling Lin
JLJixin Liu
Jixin Liu
XMXuefei Mao
Xuefei Mao
JWJianhua Wang
Jianhua Wang
DQDeyuan Qin
Deyuan Qin
A novel method of ultraviolet vapour generation (UVG) coupled with atomic fluorescence spectrometry (AFS) was developed for the determination of ultratrace inorganic arsenic (iAs) in surface water. In this work, different ferric species were utilised for the first time as an enhancement reagent for the ultraviolet vapour generation of As(III), and their UVG efficiencies for volatile species of arsenic were investigated. 15 mg L−1 of ferric chloride provided the greatest enhancement of approximately 10-fold, using 20% acetic acid combined with 4% formic acid with 30 s ultraviolet irradiation at 200 mL min−1 Ar/H2 flow rate. Under the optimised conditions, the linear range was 1.0 μg L−1–100.0 μg L−1, and the spiked recoveries were 92%–98%. The limit of detection was 0.05 μg L−1 for iAs, and the relative standard deviation (RSD) value of the repeated measurements was 2.0% (n = 11). This method was successfully applied to the determination of ultratrace iAs in tap water, river water, and lake water samples using 0.2% H2SO4 (v : v) as the sample preserver. The obtained values for the water samples of certified reference materials (CRMs) including GSB-Z50004-200431, GBW08605 and GBW(E)080390 were all within the certified ranges.

24 April 2018 in Analytical Chemistry
Verified
Journal Article
Closed access
YQYuehan Qi
Yuehan Qi
XMXuefei Mao
Xuefei Mao
JLJixin Liu
Jixin Liu
XNXing Na
Xing Na
GCGuoying Chen
Guoying Chen
YQYongzhong Qian
Yongzhong Qian

1 November 2021 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
YZYaru Zhang
Yaru Zhang
JLJixin Liu
Jixin Liu
XMXuefei Mao
Xuefei Mao
GCGuoying Chen
Guoying Chen
DTDi Tian
Di Tian

10 April 2023 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
SXShuanglei Xie
Shuanglei Xie
CPChuanqi Pan
Chuanqi Pan
YYYuan Yao
Yuan Yao
XYXianglin Yu
Xianglin Yu
ZXZe Xu
Ze Xu
YGYanbing Guo
Yanbing Guo
A satisfactory material with high adsorption capacity is urgently needed to solve the serious problem of environment and human health caused by lead pollution. Herein, hydrogen-substituted graphdiyne (HsGDY) was successfully fabricated and employed to remove lead ions from sewage and lead-containing blood. The as-prepared HsGDY exhibits the highest adsorption capacity of lead among the reported materials with a maximum adsorption capacity of 2,390 mg/g, i.e., ~five times larger than that of graphdiyne (GDY). The distinguished hexagonal hole and stack mode of HsGDY allows the adsorption of more lead via its inner side adsorption mode in one single unit space. In addition, the Pb 6s and H 1s hybridization promotes the strong bonding of lead atom adsorbed at the acetylenic bond of HsGDY, contributing to the high adsorption capacity. HsGDY can be easily regenerated by acid treatment and showed excellent regeneration ability and reliability after six adsorption-regeneration cycles. Langmuir isotherm model, pseudo second order, and density functional theory (DFT) demonstrated that the lead adsorption process in HsGDY is monolayer chemisorption. Furthermore, the HsGDY-based portable filter can handle 1,000 μg/L lead-containing aqueous solution up to 1,000 mL, which is nearly 6.67 times that of commercial activated carbon particles. And, the HsGDY shows good biocompatibility and excellent removal efficiency to 100 μg/L blood lead, which is 1.7 times higher than that of GDY. These findings suggest that HsGDY could be a promising adsorbent for practical lead and other heavy metal removal.