Mrinal Kanti Bhowmik

Dr. Mrinal Kanti Bhowmik


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2019 in Infrared Physics & Technology
Verified
Journal Article
Closed access
UGUsha Rani Gogoi
Usha Rani Gogoi
GMGautam Majumdar
Gautam Majumdar
MBMrinal Kanti Bhowmik
Mrinal Kanti Bhowmik
AGAnjan Kumar Ghosh
Anjan Kumar Ghosh

29 August 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SPSourav Pramanik
Sourav Pramanik
DBDebapriya Banik
Debapriya Banik
DBDebotosh Bhattacharjee
Debotosh Bhattacharjee
MNMita Nasipuri
Mita Nasipuri
MBMrinal Kanti Bhowmik
Mrinal Kanti Bhowmik
GMGautam Majumdar
Gautam Majumdar
Segmentation of suspicious regions (SRs) of a thermal breast image (TBI) is a very significant and challenging problem for identification of breast cancer. Therefore, in this work, we have proposed an active contour model for the segmentation of the SRs in a TBI. The proposed segmentation method combines three significant steps. First, a novel method, called smaller-peaks corresponding to the high-intensity-pixels and the centroid-knowledge of SRs (SCH-CS), is proposed to approximately locate the SRs, whose contours are later used as the initial evolving curves of the level set method (LSM). Second, a new energy functional, called different local priorities embedded (DLPE), is proposed regarding the level set function. DLPE is then minimized using the interleaved level set evolution to segment the potential SRs in a TBI more accurately. Finally, a new stopping criterion is incorporated into the proposed LSM. The proposed LSM not only increases the segmentation speed but also ameliorates the segmentation accuracy. Performance of our SR segmentation method was evaluated on two TBI databases, namely, DMR-IR and DBT-TU-JU and the average segmentation accuracies obtained on these databases are 72.18% and 71.26% respectively, which are better than other state-of-the-art methods. Beside this, a novel framework to analyze TBIs is proposed for differentiating abnormal and normal breasts on the basis of the segmented SRs. We have also shown experimentally that investigating only the SRs instead of the whole breast is more effective in differentiating abnormal and normal breasts.

17 August 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MBMrinal Kanti Bhowmik
Mrinal Kanti Bhowmik
UGUsha Gogoi
Usha Gogoi
GMGautam Majumdar
Gautam Majumdar
DBDebotosh Bhattacharjee
Debotosh Bhattacharjee
DDDhritiman Datta
Dhritiman Datta
AGAnjan Ghosh
Anjan Ghosh
The advancement of research in a specific area of clinical diagnosis crucially depends on the availability and quality of the radiology and other test related databases accompanied by ground truth and additional necessary medical findings. The paper describes the creation of the Department of Biotechnology-Tripura University-Jadavpur University (DBT-TU-JU) breast thermogram database. The objective of creating the DBT-TU-JU database is to provide a breast thermogram database that is annotated with the ground truth images of the suspicious regions. Along with the result of breast thermography, the database comprises of the results of other breast imaging methodologies. A standard breast thermogram acquisition protocol suite comprising of several critical factors has been designed for the collection of breast thermograms. Currently, the DBT-TU-JU database contains 1100 breast thermograms of 100 subjects. Due to the necessity of evaluating any breast abnormality detection system, this study emphasizes the generation of the ground truth images of the hotspot areas, whose presence in a breast thermogram signifies the presence of breast abnormality. With the generated ground truth images, we compared the results of six state-of-the-art image segmentation methods using five supervised evaluation metrics to identify the proficient segmentation methods for hotspot extraction. Based on the evaluation results, the Fractional-Order Darwinian particle swarm optimization, Region growing, Mean shift and Fuzzy c-means clustering are found to be more efficient in comparison to k-means clustering and Threshold based segmentation methods.

1 July 2019 in IEEE Transactions on Circuits and Systems for Video Technology
Verified
Journal Article
Closed access
ASAnu Singha
Anu Singha
MBMrinal Kanti Bhowmik
Mrinal Kanti Bhowmik
Foreground segmentation of moving objects in adverse atmospheric conditions such as fog, rain, low light and dust is a challenging task in computer vision. The advantages of thermal infrared imaging at night time under adverse atmospheric conditions have been demonstrated, which are due to the long wavelength. However, existing state-of-the-art object detection techniques have not been useful in such scenarios. In this paper, we propose an improved background model that utilizes both thermal pixel intensity features and spatial video salient features. The proposed spatial video salient features are represented as an Akin-based per-pixel Boolean string over a local region block, and depend on the effect of neighbouring pixels on a centre pixel. The result of this Boolean procedure is referred to as the -‘Akin-based Local Whitening Boolean Pattern (ALWBP),’ which differentiates foreground and background region accurately, even against a cluttered background. The background model is controlled via (i) the automatic adaptation of parameters such as the decision threshold RT and, learning parameter L, and (ii) the updating of background samples Bsample-int and,- Bsample-ALWBP to minimize (a) the effect of the background dynamics of outdoor scenes, and (b) the temperature polarity changes during the maiden appearance of a moving object in thermal frame sequences. The performance of this model is evaluated using nine existing standard segmentation performance metrics on our newly created -‘Tripura University Video Dataset at Night time (TU-VDN)’ and on the publicly available CDnet-2014 dataset. Our newly created weather-degraded video dataset, namely, TU-VDN, consists of sixty video sequences that represent four atmospheric conditions, namely, low light, dust, rain, and fog. The results of a performance comparison with fourteen state-of-the-art detection techniques also demonstrate the high accuracy of the proposed technique.

31 August 2018 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
UGUsha Gogoi
Usha Gogoi
MBMrinal Kanti Bhowmik
Mrinal Kanti Bhowmik
DBDebotosh Bhattacharjee
Debotosh Bhattacharjee
AGAnjan Kumar Ghosh
Anjan Kumar Ghosh

15 December 2020 in Quantitative InfraRed Thermography Journal
Verified
Journal Article
Closed access
SBShawli Bardhan
Shawli Bardhan
SNSatyabrata Nath
Satyabrata Nath
TDTathagata Debnath
Tathagata Debnath
DBDebotosh Bhattacharjee
Debotosh Bhattacharjee
MBMrinal Kanti Bhowmik
Mrinal Kanti Bhowmik
Limited application of thermography for inflammatory joint disease diagnosis is due to unavailability of joint thermogram dataset and formulated protocol of data acquisition. Focusing on the limitations, we aimed on creation and analysis of knee thermogram dataset by introducing standardized protocols of acquisition. The dataset named as “Infrared Knee Joint Dataset”, and includes healthy, and three different types of arthritis affected knee thermograms. Dataset validation and inflammation oriented ground truth generation procedures are also mentioned in this study. After data acquisition, thermograms are preprocessed and segmented. Finally, the system separates healthy and abnormal knee thermograms, and classifies those abnormal thermograms into three classes. For the classification, conventional feature-based techniques combined with shallow learning as well as deep learning have been used. The experimental results show the following: 1) classification of healthy and arthritis affected knee thermogram achieved 92% accuracy with SVM and 96% using VGG19; 2) In inter-arthritis classification VGG16 has shown the highest accuracy of 86% through ROI-based classification. Creation of standardized knee thermogram dataset and application of deep learning methodology diagnosis arthritis-oriented knee abnormality non-invasively. The described database acquisition protocol and classification strategies could contribute to the designing of accurate and robust image-based arthritis diagnosis systems.