The study aim was to evaluate a small low-field NMR (nuclear magnetic resonance) scanner, the NMR-MOUSE®, for detecting changes in intestinal diffusion under different (patho-) physiological perfusion states. Laparotomy was performed on 8 female landrace pigs (body weight 70±6 kg) and the feeding vessels of several intestinal loops were dissected. Successively, the intestinal loops were examined using O2C (oxygen to see, LEA Medizintechnik GmbH, Giessen, Germany) for microcirculatory monitoring and the NMR-MOUSE® for diffusion measurement (fast and slow components). On each loop the baseline measurement (physiological perfusion) was followed by one of the following main procedures: method 1 –ischemia; method 2 –flow reduction; method 3 –intraluminal glucose followed by ischemia; method 4 –intraluminal glucose followed by flow reduction. Additionally, standard perioperative monitoring (blood pressure, ECG, blood gas analyses) and histological assessment of intestinal biopsies was performed. There was no statistical overall time and method effect in the NMR-MOUSE measurement (fast component: ptime = 0.6368, pmethod = 0.9766, slow component: ptime = 0.8216, pmethod = 0.7863). Yet, the fast component of the NMR-MOUSE measurement showed contrary trends during ischemia (increase) versus flow reduction (decrease). The slow-to-fast diffusion ratio shifted slightly towards slow diffusion during flow reduction. The O2C measurement showed a significant decrease of oxygen saturation and microcirculatory blood flow during ischemia and flow reduction (p < .0001). The local microcirculatory blood amount (rHb) showed a significant mucosal increase (pClamping(method 1) = 0.0007, pClamping(method 3) = 0.0119), but a serosal decrease (pClamping(method 1) = 0.0119, pClamping(method 3) = 0.0078) during ischemia. The histopathological damage was significantly higher with increasing experimental duration and at the end of methods 3 and 4 (p < .0001,Fisher-test). Monitoring intestinal diffusion changes due to different perfusion states using the NMR-MOUSE is feasible under experimental conditions. Despite the lack of statistical significance, this technique reflects perfusion changes and therefore seems promising for the evaluation of different intestinal perfusion states in the future. Beforehand however, an optimization of this technology, including the optimization of the penetration depth, as well as further validation studies under physiological conditions and including older animals are required.
4 November 2025 in European Journal of Vascular and Endovascular Surgery
This study aimed to report the early outcomes of fenestrated endovascular aneurysm repair (FEVAR) performed with the BeFlared bridging stent (Bentley, Hechingen, Germany), a new dedicated bridging stent mounted on a stepped balloon. The study included consecutive patients treated with FEVAR exclusively performed with BeFlared as the bridging stent at 11 high volume centres between November 2024 and April 2025. Patient demographics, target vessel (TV) anatomy, and post-operative patient and stent outcomes were prospectively collected in an electronic database. Computed tomography angiography (CTA) imaging was performed within the first post-operative month. The composite primary endpoint was the freedom from target vessel instability (TVI) rate of stented target vessels. Eighty-four patients were included (75 males, 73.2 ± 7.3 years). TV catheterisation failed in two of 312 (0.6%) TV. BeFlared stenting was successful in all cases after TV catheterisation (n = 310). During the procedure, 13 BeFlared stents (4.2%) required secondary inflation and additional stents were implanted in six TVs (1.9%). The mean procedural time was 162 ± 60 minutes. On completion angiogram, all stents were patent and one renal stent type IC endoleak was noted (0.3%). Post-operative CTA confirmed the intra-operative type IC endoleak (0.3%), which is pending re-intervention, and additionally revealed one renal stent stenosis (0.3%). There were no stent occlusions, kinking, fracture, or stent related secondary procedures, resulting in a freedom from TVI of stented TV at 1 month of 99.3%. In this first multicentric, prospective clinical report involving 84 patients treated across 11 expert centres, the BeFlared bridging stent demonstrated favourable early safety and effectiveness.
The perioperative inflammatory response is associated with outcome after complex aortic repair. Macrophage migration inhibitory factor (MIF) shows protective effects in ischemia-reperfusion (IR), but also adverse pro-inflammatory effects in acute inflammation, potentially leading to adverse outcome, which should be investigated in this trial. This prospective study enrolled 52 patients, of whom 29 (55.7%) underwent open repair (OR) and 23 (44.3%) underwent endovascular repair (ER) between 2014 and 2015. MIF serum levels were measured until 72 h post-operatively. We used linear mixed models and ROC analysis to analyze the MIF time-course and its diagnostic ability. Compared to ER, OR induced higher MIF release perioperatively; at 12 h after ICU admission, MIF levels were similar between groups. MIF course was significantly influenced by baseline MIF level (P = 0.0016) and acute physiology and chronic health evaluation (APACHE) II score (P = 0.0005). MIF level at 24 h after ICU admission showed good diagnostic value regarding patient survival [sensitivity, 80.0% (28.4–99.5%); specificity, 51.2% (35.1–67.1%); AUC, 0.688 (0.534–0.816)] and discharge modality [sensitivity, 87.5% (47.3–99.7%); specificity, 73.7% (56.9–86.6%), AUC, 0.789 (0.644–0.896)]. Increased perioperative MIF-levels are related to an increased risk of adverse outcome in complex aortic surgery and may represent a biomarker for risk stratification in complex aortic surgery.
Summary: Background: The objective of the study was to analyze mid-term results of unselected patients treated with the TREO (Terumo Aortic, Florida, USA) device at six German hospital sites. Methods: A multicenter, retrospective analysis of patients treated within and outside instructions for use (IFU) from January 2017 to November 2020 was performed. Primary outcomes were technical success, mortality and endograft related complications according to IFU status. Secondary outcomes were aneurysm/procedure related re-interventions. Results: 150 patients (92% male, mean age 73 ±8 years) were treated (within IFU 84% vs. outside IFU 16%) with the TREO device for abdominal aortic aneurysms (n=127 intact, n=17 symptomatic and n=6 ruptured; p=0.30). Technical success was achieved in 147/150 (within IFU 99% vs. outside IFU 92%, p=0.08). 30-day mortality was 2%, one year and overall mortality was 3% and 5%. During a mean follow-up of 28.4 months (range: 1–67.4 months), 35 (25%; within IFU 23% vs. outside IFU 35%, p=0.23) patients suffered from endoleaks. The majority were endoleaks type II (n=33), the remaining type Ia (n=5) and type Ib (n=3). No endoleaks type III-V, migrations or aneurysm ruptures occurred. Overall, 19 patients (13%; within IFU 13% vs. 15% outside IFU, p=0.70) received a secondary intervention: nine endoleak related endovascular procedures, three open conversions, two endograft limb related interventions, four surgical revisions of the femoral access sites and two bowl ischemia related procedures, respectively. Conclusions: This non industry-sponsored, multicenter trial indicates that using the TREO device in a real-world setting (both within and outside IFU) seems feasible in the treatment of patients suffering from AAA. While the rate of complications and secondary interventions is in line with previously published data, the findings highlight the fact that standard EVAR is associated with serious adverse events.