The droop-free control for ac microgrids achieves active power sharing and frequency regulation by replacing the centralized secondary control and the primary-level droop mechanism by a cooperative distributed control strategy. This article analyses the performance of the droop-free control when an islanded microgrid suffers electrical and communication failures. The microgrid is modeled by two connected graphs corresponding to the electrical and communication networks. The considered failures leads to partitioned electrical/communication subgraphs that coexist within the microgrid. A closed-loop model integrating the power flow equations, the droop-free control, and the electrical and communication graphs is derived. The stability analysis identifies critical partitions where the microgrid is driven to the instability, and the steady-state analysis characterizes the equilibrium points when the partitioned microgrid remains stable. This article also provides a control strategy that is able to avoid the instability scenario. Selected experimental results on a low-scale laboratory microgrid illustrate the impact that failures have in system performance and the ability of the proposed control for confining the microgrid operation into a safe region.
22 October 2018 in IEEE Transactions on Smart Grid
Microgrids are power systems consisting of an electrical network composed by distributed loads and generation units that may include a communication network for improved operation. The considered microgrid in islanded mode is driven by voltage source inverters implementing decentralized droop control for active power sharing together with a communication-based consensus algorithm for frequency regulation. This paper analyses the microgrid performance subject to network failures that provoke network partitions. It is considered that the electrical partition leads to several sub-microgrids working in parallel where the power demand can be always guaranteed by the generation units, and the communication partition leads to several consensus algorithms also working in parallel. The double partitioning is analyzed through a closed-loop system model derived using the power flow equations that includes the electrical and communication connectivity. Analytical expressions for the steady-state values for both frequency and active power depending on the partitioning are derived. Selected experimental results on a low-scale laboratory microgrid illustrate the (undesirable) impact that unexpected partitions have in system performance.
Discrepancies between laboratory vehicle performance and real-world traffic conditions have been reported in numerous studies. In response, emission and fuel regulatory frameworks started incorporating real-world traffic evaluations and vehicle monitoring using portable emissions measurement systems (PEMS) and on-board diagnostic (OBD) data. However, in regions with technical and economic constraints, such as Latin America, the use of PEMS is often limited, highlighting the need for low-cost methodologies to assess vehicle performance. OBD interfaces provide extensive vehicle and engine operational data in this context, offering a valuable alternative for analyzing vehicle performance in real-world conditions. This study proposes a straightforward methodology for assessing vehicle fuel efficiency and carbon dioxide (CO2) emissions under real-world traffic conditions using OBD data. An experimental campaign was conducted with three gasoline-powered passenger vehicles representative of the Ecuadorian fleet, operating as urban taxis in Ibarra, Ecuador. This methodology employs an OBD interface paired with a mobile phone data logging application to capture vehicle kinematics, engine parameters, and fuel consumption. These data were used to develop engine maps and assess vehicle performance using the vehicle-specific power (VSP) approach based on the energy required for vehicle propulsion. Additionally, VSP analysis combined with OBD data facilitated the development of an energy-emission model to characterize fuel consumption and CO2 emissions for the tested vehicles. The results demonstrate that OBD systems effectively monitor vehicle performance in real-world conditions, offering crucial insights for improving urban transportation sustainability. Consequently, OBD data serve as a critical resource for research supporting decarbonization efforts in Latin America.
A vehicle interacts with the road, other vehicles, and traffic control devices in real traffic conditions. The level of traffic influences driving patterns and, consequently, this can affect the vehicle´s fuel efficiency and emissions. This study aims to develop engine maps of fuel consumption and CO2 emissions for a light vehicle operating under real traffic conditions. A representative passenger vehicle of the Ecuadorian vehicle fleet, powered by gasoline, was selected for the experimental campaign that was developed on a test route designed according to real driving emission (RDE) regulation. An on-board diagnostic (OBD) device was used for recording in real-time engine and vehicle operating parameters. Moreover, CO2 emissions were estimated using the fuel rate registered from the OBD system of the vehicle This study proposed a novel methodology for developing two-dimensional contour engine maps based on OBD data. The result showed that the vehicle engine operated in real traffic conditions with a brake thermal efficiency (BTE) of 27%, a brake-specific fuel consumption (BSFC) of 275 g/kWh, and a carbon dioxide (CO2) energy-emission factor of 716 g/kWh. In terms of distance, the CO2 emission factor for the tested vehicle was approximately 190 g/km. Overall, this study demonstrates that the OBD approach is a potential method to be used to assess the fuel consumption and emissions of a vehicle operating under real-world traffic conditions, especially in Latin American countries, where portable emission measurement systems (PEMS) are not readily available.
This paper proposes a local sliding mode control (SMC) strategy for frequency regulation and active power sharing in islanded microgrids (MGs). Unlike advanced strategies, either droop-based or droop-free, that rely on inter-inverter communication, the proposed method operates in a fully decentralized manner, using only measurements available at each inverter. In addition, it adopts a minimalist structure that avoids adaptive laws and consensus mechanisms, which simplifies implementation. A discontinuous control law is derived to enforce sliding dynamics on a frequency-based surface, ensuring robust behavior in the face of disturbances, such as clock drifts, sudden load variations, and topological reconfigurations. A formal Lyapunov-based analysis is conducted to establish the stability of the closed-loop system under the proposed control law. The method guarantees that steady-state frequency deviations remain bounded and predictable as a function of the controller parameters. Simulation results demonstrate that the proposed controller achieves rapid frequency convergence, equitable active power sharing, and sustained stability. Owing to its communication-free design, the proposed strategy is particularly well-suited for MGs operating in rural, isolated, or resource-constrained environments. A comparative evaluation against both conventional droop and communication-based droop-free SMC approaches further highlights the method’s strengths in terms of resilience, implementation simplicity, and practical deployability.
This paper introduces a simple decentralized sliding-mode (SM) approach to control active power sharing by regulating the local frequency in inverter-based islanded microgrids (MGs). Its sliding surface arises from the frequency correction term introduced in the droop-free technique; it relates local active power to neighboring MGs’ active power by considering available communications among voltage source inverters. Then, this schema allows one to avoid hierarchical control just as the droop-free method does, and the benefits associated are twofold. First, it reduces the steady-state frequency error while providing accurate active power distribution. Second, the system stays reliable, withstands uncertainties, and provides a fast transient response. A Lyapunov analysis confirms stability, and simulations on a realistic four-inverter MG platform substantiate the control scheme’s effectiveness. Its performance regards frequency regulation while achieving active power sharing, stability, and robustness against clock drifts and load steps.