Akihiro Hamanaka

Dr. Akihiro Hamanaka

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2023 in Energy
Verified
Journal Article
Closed access
FSFa-Qiang Su
Fa-Qiang Su
XHXiao-Long He
Xiao-Long He
MDMeng-Jia Dai
Meng-Jia Dai
JYJun-Nan Yang
Jun-Nan Yang
AHAkihiro Hamanaka
Akihiro Hamanaka
JLJiao-Yuan Li
Jiao-Yuan Li

1 June 2015 in Journal of Rock Mechanics and Geotechnical Engineering
Verified
Journal Article
Open access
TSTakashi Sasaoka
Takashi Sasaoka
HTHiroshi Takamoto
Hiroshi Takamoto
HSHideki Shimada
Hideki Shimada
JOJiro Oya
Jiro Oya
AHAkihiro Hamanaka
Akihiro Hamanaka
KMKikuo Matsui
Kikuo Matsui
Subsidence analysis and prediction with measured data have been conducted and applied to local strata and mining conditions worldwide. Underground coal mines chose the most suitable analysis and prediction method for them. However, there was no study based on the measured data of subsidence induced by underground mining operation in Indonesia. This paper describes the condition of underground coal mine in Indonesia and then discusses the subsidence behavior due to longwall mining operation based on measured data in Balikpapan coal-bearing formation in Indonesia

9 August 2013 in International Journal of Mining, Reclamation and Environment
Verified
Journal Article
Closed access
HSHideki Shimada
Hideki Shimada
AHAkihiro Hamanaka
Akihiro Hamanaka
TSTakashi Sasaoka
Takashi Sasaoka
KMKikuo Matsui
Kikuo Matsui
In underground coal mines, floor heave is a major problem that is caused by groundwater, high strata stress and weak floors. Controlling the stability of the roadways is the key to maintaining the safety and efficiency of underground mining. Appropriate cement grouting is an effective and attractive floor reinforcement technique that can control excessive floor heave and closure. Cement grouting also reduces the permeability of the rock mass and consequently controls the movement of groundwater into the roadway. Injecting cement grout into roadway floors provides a more uniform reinforcement throughout the floor. It may even be possible to reinforce an extremely fractured floor. In this respect, this technique is superior to floor bolting/dowelling. This technique may be performed either as a pre- or post- development reinforcement. It is very difficult, however, to reinforce a floor that is not heavily fractured by the injection technique. Therefore, before floor injection, floor blasting is performed in order to create an adequate number of fractures in the floor. Fracturing by blasting also relieves and improves stress conditions in the floor. From this point of view, the behaviour of grouting injection as floor reinforcement material is discussed. That is to say that the results of an injection analysis, an injection experiment and a viscosity measurement to understand the injection process of cement grout into soil voids were studied. The injection analysis was performed by combining two analyses, the analysis of the clogging process, and the analysis of the transportation process. As to the analysis of the transportation process, since a cement-based grouting material can be described as a Bingham fluid, the equation of plug flow related to a Bingham fluid inside a circular pipe, instead of Darcy’s law, was expanded and analysed. The injection experiment was performed under low-pressure on a decomposed granite sample. The injection s experiment was performed using three mixtures with cement/water ratios (C/W) of 1/10, 1/5, and 1/3.5, respectively, to examine the influence of variable cement/water ratios. The viscosity model is proposed from the result measured with the aid of Brookfield viscometer. To calculate yield stress, viscosity data obtained with the Brookfield viscometer was used. However, for the determination of plastic viscosity, because some cement particles will be in the state of aggregation and so on, the viscosity measurements obtained by the use of the Brookfield viscometer are overestimated in comparison with a theoretical equation that assumed that cement particles are dispersed in the solution completely. However, it is thought that cement particles cannot form aggregates easily in the soil voids or cracks. Therefore, the plastic viscosity model of grouting material is expected to follow the proposed theoretical equation. Finally, the assumption that the grouting material was injected in the state of laminar flow was verified by data obtained from the Lugeon test. The field data which are satisfied with this condition is simulated using the plastic viscosity and the yield stress model of grouting material.

1 August 2018 in Applied Energy
Verified
Journal Article
Closed access
FSFaqiang Su
Faqiang Su
AHAkihiro Hamanaka
Akihiro Hamanaka
KIKen-Ichi Itakura
Ken-Ichi Itakura
WZWenyan Zhang
Wenyan Zhang
GDGota Deguchi
Gota Deguchi
JKJun-Ichi Kodama
Jun-Ichi Kodama

16 April 2018 in Geosciences
Verified
Journal Article
Open access
PDF file
SMShinji Matsumoto
Shinji Matsumoto
SOShunta Ogata
Shunta Ogata
HSHideki Shimada
Hideki Shimada
TSTakashi Sasaoka
Takashi Sasaoka
AHAkihiro Hamanaka
Akihiro Hamanaka
GKGinting Jalu Kusuma
Ginting Jalu Kusuma
Soil water erosion is frequently reported as serious problem in soils in Southeast Asia with tropical climates, and the variations in pH affect the development of the erosion. This study investigated the effects of changes in pH on soil water erosion based on changes in the physical properties of the simulated soils with pH adjusted from 2.0 to 10.0 through artificial rainfall tests. The zeta potential was entirely shifted to positive direction at each pH condition due to Al, Ca, and Mg. In the pH range of 6.0 to 2.0, the aggregation of soil particles resulting from the release of Al3+ from clay minerals and/or molecular attraction between soil particles caused the plastic index (IP) of the soil to decrease. The decrease in IP led to the development of soil water erosion at the pH range. When the pH exceeded 6.0, the repulsive force generated by the negative charges on soil particles decreased IP, resulting in accelerated erosion by water. The results suggest that changes in pH causes physical properties of the soil to change through changes of the zeta potential in the clayey soil rich in Al, Ca, and Mg, leading to the development of soil water erosion.

21 September 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
Zhiyi ZhangZhiyi Zhang
Zhiyi Zhang
HSHideki Shimada
Hideki Shimada
TSTakashi Sasaoka
Takashi Sasaoka
AHAkihiro Hamanaka
Akihiro Hamanaka
Stability of the retained goaf-side gateroad (RGSG) is influenced mainly by the movements of the roof strata near coal seam after coalface passes by. To make effective controlling technology for the stability of the RGSG, we analyze the roof structure over the RGSG to illustrate the mechanism causing the RGSG instability under different roof conditions. We then examine the dynamic evolution of the deformation and abutment stress in the rock surrounding the RGSG during coal seam mining, using the FLAC3D numerical software to reveal the instability characteristics of the RGSG under different roof conditions. Next, corresponding stability controlling technologies for the RGSGs are proposed and tested in three typical deep underground coalmines. Results show that: sink and rotation of the roof cantilever over the RGSG impose severer influence on the stability of the RGSG. The RGSG suffers disturbances three times during the coal-seam mining, and the deformation and abutment stress in the rock surrounding the RGSG increase significantly when the main roof becomes thicker and the immediate roof becomes thinner. Staged support technology involving grout cable bolts has better controlling results of the RGSG stability than that composed of conventional rock bolts, when the RGSG is beneath weak immediate roof with large thickness. Roof structure optimizing technology involving pre-split technology can improve the stability of the RGSG effectively when the RGSG is covered by hard main roof with large thickness directly.