To study the flexural behavior of a composite beam, original single and double bamboo beams (SBBs and DBBs, respectively) and sprayed lightweight composite mortar-original bamboo composite beams (SCBs and DCBs) were designed and subjected to a four-point bending test based on the moisture content of the original bamboo. The failure modes, bearing capacity, and initial flexural rigidity of all of the beams were analyzed. Also, the strengthening effect of the lightweight composite mortar on the flexural behavior was studied. The results showed that a higher moisture content in the bamboo degraded the anti-slip property of the bond interface between the lightweight composite mortar and bamboo. The moisture content of the bamboo should be kept at approximately 20% before spraying. The initial flexural rigidity and bearing capacity of the DBBs were approximately 2.5 times and twice that of the SBBs, respectively. The initial flexural rigidities of the SCBs and DCBs were approximately 3.8 and 5.7 times that of the SBBs and DBBs, respectively. The ultimate load bearing capacity of the composite beams was approximately 1.5 times that of the original bamboo beams. It was shown that the lightweight composite mortar had a remarkable strengthening effect on the flexural behavior of the original bamboo.
27 July 2021 in European Journal of Wood and Wood Products
Long-span, single-layer spatial grid structures are widely used in public buildings. The progressive collapse of such structures could cause great losses of property and human life. To accurately capture the performance of a structure in progressive collapse, an efficient dynamic behavior analysis should be conducted. In this paper, a multi-degree-of-freedom simplified model was established to represent the progressive-collapse dynamic behavior of single-layer spatial grid structures. Based on the simplified model, two dynamic behavior modes were identified: ordinary and specific dynamic behaviors. In ordinary dynamic behavior, the dynamic effect caused by local failure cannot be transmitted, and the displacement responses of the joints in the failure area are symmetrically distributed based on the final equilibrium states, with the gradual attenuation of the dynamic effect. For the specific dynamic behavior, the dynamic effect is transmitted and a disorganized response of single-layer spatial grid structures occurs. Furthermore, the dynamic progressive-collapse behaviors of six full-scale typical domes were analyzed with a verified numerical simulation. The results indicate that a multi-degree-of-freedom system is necessary for accurately reflecting the dynamic behavior of single-layer spatial grid structures. The middle position between vertex and supports can be defined as the important area of reticulated domes, where a member’s failure would have a significant effect on structural performance. If a specific dynamic behavior plays a dominant role in the overall structure, the progressive-collapse resistance may be improved for a single-layer spatial grid structure.
Composite structural insulated panels (CSIPs) are eco-friendly, high-performance materials, which not only good have mechanical properties, but also good waterproof, moisture-proof, fire-proof, and anti-corrosion characteristics, so they have been used to build envelope structures in recent years. However, how to improve stiffness of CSIPs remains unsolved. The poor stiffness is one of the biggest obstacles for the application of CSIPs in the load-bearing members of civil engineering. In this study, the layout of glass–polypropylene (PP) laminate layers is designed to enhance its stiffness, and this study applies CSIPs as load-bearing members of civil engineering for the first time. Thus, the bend model of CSIP thin-wall box-beams under uniform loading is built, based on Timochenko’s theory. The deflection curve equation is presented, considering shearing deformation. The expressions for the bending of normal strain flanges of the beam and the equation considering principal shearing strain at the beam’s web are obtained, respectively. Finally, mechanical properties of the thin-wall box-beam under uniformly distributed loads were performed by FE. FE results are entirely consistent with the theoretical results, thereby making the theoretical method applicable for the design of thin-wall box-beams, which are made of composite materials. Different from other beams, the shearing deformation is a critical factor that influences the deformation of thin-walled box-beams.
To effectively improve the anti-progressive collapse performance of steel frames, a novel reinforced joint, named the welded steel-frame joints strengthened by outer corrugated plates, was proposed. Firstly, the finite element model was validated according to previous test results. The anti-progressive collapse behavior of the novel reinforced joint was analyzed based on the validated modeling method. Effects of the central angle, corrugated plate thickness, corrugated plate width, length of circular arc, and welding angle on the anti-progressive collapse behavior of the reinforced joint were discussed. The design suggestions of the corrugated plates are presented. Finally, the effectiveness of the outer corrugated plates was further verified through one full-scale beam–column joint case and three plane frames. The results show that compared with the specimen strengthened by inner corrugated plates, the peak load and ultimate displacement of the joint strengthened by outer corrugated plates increased by 17.0% and 16.3%, respectively. Compared with the traditional full-scale beam–column joint, the load-bearing capacity and ultimate displacement of the joint strengthened by outer corrugated plates designed under reasonable suggestions significantly increased. Simply from the perspective of joints, the design suggestions were highly effective. Compared with the traditional plane steel-frame case with a total height of six floors, the bearing capacity and ultimate displacement of the plane steel-frame case strengthened by outer corrugated plates increased by 19.8% and 38.3%, respectively. The outer corrugated plates demonstrated a more pronounced effect in enhancing the collapse resistance for middle floors. Overall, the novel type of joint had a simple form and clear mechanical principles, which fully exerted the catenary capacity of the steel beams. The outer corrugated plates significantly improved the anti-progressive collapse performance of steel-frame structures.