The quality of the drinking water distributed through the networks has become the main concern of most operators. This work focuses on one of the most important variables of the drinking water distribution networks (WDN) that use disinfection, chlorine. This powerful disinfectant must be dosed carefully in order to reduce disinfection byproducts (DBPs). The literature demonstrates researchers’ interest in modelling chlorine decay and using several different approaches. Nevertheless, the full-scale application of these models is far from being a reality in the supervision of water distribution networks. This paper combines the use of validated chlorine prediction models with an intensive study of a large amount of data and its influence on the model’s parameters. These parameters are estimated and validated using data coming from the Supervisory Control and Data Acquisition (SCADA) software, a full-scale water distribution system, and using off-line analytics. The result is a powerful methodology for calibrating a chlorine decay model on-line which coherently evolves over time along with the significant variables that influence it.
This paper presents a model, based on potential curves, that describes the behaviour of the inverse of the daily cumulated frequency of the flows provided to a District Metered Area (DMA). The model has two terms, the first corresponds to the variable consumption due to the aggregation of demand patterns of consumers. The evolution of this term presents periodic behaviours with annual and weekly frequency. An extreme drought episode that affected Catalunya, reduced this parameter 19%. A second term presents exponential behaviour in its evolution and includes the real leakage. The leakage disaggregation together with the billing information allows the estimation of the apparent loses, 14.89% in the case study. The difficulty of estimating the parameters in a potential model, a complex problem of optimization, is simplified by applying mathematical moments. Hence, daily parameters become a linear relation of the daily moments that allows their algebraic operation.
This article describes the development and implementation of a water resource management system utilizing open technologies such as the ESP32 microcontroller and MicroPython. This system stands out for its low cost, high efficiency and adaptability to various environments, thanks to the integration of free or low-cost communications such as LoRaWAN and NB-IoT, as well as the use of open-source programming, which offers flexibility. The article details the use of JSN-SR04T ultrasonic sensors, manufactured by JINZHAN, a company based in China, for water-level measurement and the use of 3D printing to manufacture customized components, demonstrating a scalable and replicable solution for efficient water management.
In this work, an automatic distribution of the pressure reduction valves (PRVs) is proposed. First, a well-calibrated hydraulic model is required. The model of Manresa, a city of Catalunya in the Mediterranean area, was calibrated using pressure sensors, and the background leakage was estimated using weighted emitter coefficients. Simulating the model in real boundary conditions highlights the areas of maximum background leakage. The manual introduction of a PRV shows its effectiveness regarding leakage reduction. An algorithm for finding the high-pressure areas and their boundary pipes is presented. The introduction of the PRV, taking into account the flow constraints, produces a new scenario. Finally, the leakage reduction thanks to the pressure control by means of new actuators is evaluated. The leakage is reduced by around 6%.