22 January 2024 in Buildings
Verified
Journal Article
Open access
PDF file
JKJihye Kim
Jihye Kim
DSDae Uk Shin
Dae Uk Shin
HKHeegang Kim
Heegang Kim
Data centers are energy-intensive facilities, with over 95% of their total cooling load attributed to the heat generated by information technology equipment (ITE). Various energy-saving techniques have been employed to enhance data center efficiency and to reduce power usage effectiveness (PUE). Among these, economizers using outdoor air for cooling are the most effective for addressing year-round cooling demands. Despite the simplicity of the load composition, analyzing data center cooling systems involves dynamic considerations, such as weather conditions, system conditions, and economizer control. A PUE interpretation tool was specifically developed for use in data centers, aimed at addressing the simplicity of data center loads and the complexity of system analysis. The tool was verified through a comparison with results from DesignBuilder implementing the EnergyPlus algorithm. Using the developed tool, a comparative analysis of economizer strategies based on the PUE distribution was conducted, with the aim of reducing the PUE of data centers across various climatic zones. The inclusion of evaporative cooling (EC) further improved cooling efficiency, leading to reductions in PUE by approximately 0.02 to 0.05 in dry zones. Additionally, wet zones exhibited PUE reductions, ranging from approximately 0.03 to 0.07, with the implementation of indirect air-side economizer (IASE). Sensitivity and uncertainty analysis were further conducted. The computer room air handler (CRAH) supply temperature and CRAH temperature difference were the most influential factors affecting the annual PUE. For the direct air-side economizer (DASE) and DASE + EC systems, higher PUE uncertainty was observed in zones 1B, 3B, 4B, and 5B, showing ranges of 1.17–1.39 and 1.15–1.17, respectively. In the case of the IASE and IASE + EC systems, higher PUE uncertainty was noted in zones 0A, 0B, 1A, 1B, and 2A, with ranges of 1.22–1.43 and 1.17–1.43, respectively. The distinctive innovation of the tool developed in this study is characterized by its integration of specific features unique to data centers. It streamlines the computation of cooling loads, thus minimizing the burden of input, and delivers energy consumption data for data center cooling systems with a level of precision comparable to that of commercial dynamic energy analysis tools. It provides data center engineers with a valuable resource to identify optimal alternatives and system design conditions for data centers. This empowers them to make informed decisions based on energy efficiency enhancements, thereby strengthening their ability to improve energy efficiency.

8 December 2022 in Buildings
Verified
Journal Article
Open access
PDF file
HKHeegang Kim
Heegang Kim
JKJihye Kim
Jihye Kim
Myoung Souk YeoMyoung Souk Yeo
Myoung Souk Yeo
It is not easy to dynamically analyze thermal bridges that require multi-dimensional analysis in building energy simulations, which are mostly one-dimensional platforms. To solve this problem, many studies have been conducted and, recently, a study was conducted to model a thermal bridge based on the data obtained by approaching this in a similar way to steady-state analysis, showing high accuracy. This was an early-stage study, which is only applicable when the indoor temperature is constant. By extending the study, a thermal bridge model that can be applied even when the indoor temperature changes over time in building energy simulations is proposed and validated. Since the governing equation, the heat diffusion equation, is linear, the key idea is to create and apply two thermal bridge transfer function models by expressing the heat flow that enters the room as a linear combination of the transfer function for indoor temperature and the transfer function for outdoor temperature. For the proposed thermal bridge model, the NRMSE of the model itself showed a high accuracy of 0.001, and in the verification through annual simulation using the model, the NRMSE showed an accuracy of 0.1.

2 February 2026 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
HKHeegang Kim
Heegang Kim
JKJihye Kim
Jihye Kim

21 July 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
HKHeegang Kim
Heegang Kim
JKJihye Kim
Jihye Kim
Myoung Souk YeoMyoung Souk Yeo
Myoung Souk Yeo
It is not easy to dynamically analyze thermal bridges that require multidimensional analysis in building energy simulations, which are mostly one-dimensional platforms. To solve this problem, many studies have been conducted and, recently, a study was conducted to model the thermal bridge based on the data by approaching this in a similar way to steady-state analysis, showing high accuracy. This was an early-stage study, which is only applicable when the indoor temperature is constant. By extending this study, a thermal bridge model that can be applied even when the indoor temperature changes over time is proposed and validated. Since the governing equation, the heat diffusion equation, is linear, the key idea is to create and apply two thermal bridge transfer function models by expressing the heat flow entering the room as a linear combination of the transfer function for indoor temperature and the transfer function for outdoor temperature. For the proposed thermal bridge model, the NRMSE of the model itself showed a high accuracy of 99.9%, and in the verification through annual simulation using the model, the NRMSE showed an accuracy of 88.8%.