Soume Bhattacharya

Dr. Soume Bhattacharya

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2020 in Brain Sciences
Verified
Journal Article
Open access
PDF file
ARAjay Rajaram
Ajay Rajaram
LYLawrence Yip
Lawrence Yip
Daniel MilejDaniel Milej
Daniel Milej
MSMarianne Suwalski
Marianne Suwalski
MKMatthew Kewin
Matthew Kewin
KLKeith St. Lawrence
Keith St. Lawrence
Post-hemorrhagic ventricular dilatation (PHVD) is characterized by a build-up of cerebral spinal fluid (CSF) in the ventricles, which increases intracranial pressure and compresses brain tissue. Clinical interventions (i.e., ventricular taps, VT) work to mitigate these complications through CSF drainage; however, the timing of these procedures remains imprecise. This study presents Neonatal NeuroMonitor (NNeMo), a portable optical device that combines broadband near-infrared spectroscopy (B-NIRS) and diffuse correlation spectroscopy (DCS) to provide simultaneous assessments of cerebral blood flow (CBF), tissue saturation (StO2), and the oxidation state of cytochrome c oxidase (oxCCO). In this study, NNeMo was used to monitor cerebral hemodynamics and metabolism in PHVD patients selected for a VT. Across multiple VTs in four patients, no significant changes were found in any of the three parameters: CBF increased by 14.6 ± 37.6% (p = 0.09), StO2 by 1.9 ± 4.9% (p = 0.2), and oxCCO by 0.4 ± 0.6 µM (p = 0.09). However, removing outliers resulted in significant, but small, increases in CBF (6.0 ± 7.7%) and oxCCO (0.1 ± 0.1 µM). The results of this study demonstrate NNeMo’s ability to provide safe, non-invasive measurements of cerebral perfusion and metabolism for neuromonitoring applications in the neonatal intensive care unit.

24 September 2021 in American Journal of Perinatology
Verified
Journal Article
Closed access
PDF file
SBSoume Bhattacharya
Soume Bhattacharya
BRBrooke Read
Brooke Read
MMMichael Miller
Michael Miller
OSOrlando da Silva
Orlando da Silva
Objective Surfactant delivery via a thin endotracheal catheter during spontaneous breathing; a technique called minimally invasive surfactant therapy (MIST) is an alternative to intubation and surfactant administration. Procedural details among different centers vary, with marked differences in the choice of catheter to instill surfactant. Studies report use of feeding catheters, multiaccess suction catheters, vascular catheters, and more recently custom-built catheters for this purpose. The impact of choice of catheter on procedural success and procedural adverse effects has not been reported. Our present study compares the procedural success and adverse effects of MIST using a semirigid vascular catheter (16G Angiocath-Hobart Method) versus a flexible multiaccess catheter (MAC). Study Design This was a retrospective review of prospectively collected data at a tertiary care neonatal intensive care unit in Southwestern Ontario. All neonates who received surfactant via MIST between May 1, 2016 and September 30, 2020 were included in the study. Relevant baseline characteristics and data on procedural details (premedication, type of catheter, etc.) were collected. The procedural success, number of attempts, and adverse effects between neonates who received MIST via MAC and 16G Angiocath was compared by using Chi-square test or Fisher's test as appropriate. A p-value of less that 0.05 was considered significant. Results A total of 139 neonates received surfactant via MIST method during the study period. Moreover, 93 neonates received the surfactant via MAC, while 46 received it via Angiocath. The baseline demographic characteristics in the two group were similar. A higher proportion of neonates in Angiocath group received Atropine (100 vs. 76%, p = 0.002) and Fentanyl (98 vs. 36%, p < 0.001) than the MAC group.The procedural success was 91% in the Angiocath group and 89% in the MAC group (p > 0.99). Multiple attempts were needed in 24% of neonates in the Angiocath group and 37% in the MAC group (p = 0.158). More episodes of desaturations were noted in the Angiocath group (89%) than the MAC group (69%; p = 0.012). Other rates of common adverse effects were similar between the two groups. On exploratory analysis fentanyl use held significant association with less success, more desaturation, apneic episodes, and need of positive pressure ventilation /intubation. Conclusion The overall procedural success of MIST is similar in both catheter groups. The proportion of neonates requiring multiple attempts was lower with the Angiocath, though difference was not statistically significant. Desaturation episodes were seen more frequently in the Angiocath group, which was related to higher use of procedural sedation in this group. Key Points

28 July 2022 in Canadian Journal of Respiratory Therapy
Verified
Journal Article
Open access
SBShaily Brahmbhatt
Shaily Brahmbhatt
BRBrooke Read
Brooke Read
OSOrlando Da Silva
Orlando Da Silva
SBSoume Bhattacharya
Soume Bhattacharya
Minimally invasive surfactant therapy (MIST) can be used to treat neonatal respiratory distress syndrome in neonatal intensive care units (NICUs). Clinical and institutional variances in MIST utilization persist globally with little published research regarding MIST utilization in Canada. Therefore, the objective of this study was to survey MIST utilization in NICUs in Canada. An online survey was emailed to the 33 participating centres of Canadian Neonatal NetworkTM (CNN) Evidence-based Practice for Improving Quality (EPIQ) Lung Health Group (LHG). Site demographics and surfactant therapy procedural details were categorically collected. Free text and multiple-choice questions were utilized to capture perceived barriers and individual preferences for MIST use. Twenty-eight of 33 participating members of the CNN EPIQ-LHG completed the survey between April 2021 and October 2021 (85%); 17/28 (61%) respondents reported ongoing MIST utilization at their center. Most centers that used MIST techniques administered bovine lipid extract surfactant (68%), commonly using angiocatheters (47%) and purpose-built catheters (41%). MIST was widely used for patients at 26–33 weeks gestational age (88%). Nine centres had never used MIST (32%), and 3 indicated a plan to implement MIST within the next 2 years. Common barriers to MIST use included lack of consensus amongst clinicians (78%), lack of training (56%), and lack of experience with MIST (56%). While MIST is being increasingly used in Canadian NICUs, universal use is yet to be seen. Clinician inexperience and lack of consensus, formal training, and local guidelines contribute to underutilization of MIST. Training workshops, country-wide data collection, and uniform operating protocols are needed to standardize practice.

15 September 2023 in American Journal of Perinatology
Verified
Journal Article
Closed access
PDF file
AHAbdulaziz Homedi
Abdulaziz Homedi
AHAndrea Carolina De La Hoz
Andrea Carolina De La Hoz
MMMichael R. Miller
Michael R. Miller
RLRenjini Lalitha
Renjini Lalitha
MMMarisha McClean
Marisha McClean
SBSoume Bhattacharya
Soume Bhattacharya
Objective Comprehensive assessment of hemodynamic significance of a patent ductus arteriosus (PDA) is a common indication to perform targeted neonatal echocardiography (TNE). Impact of implementation of such an assessment on PDA management decisions remains to be reported. The objective of this study is to compare PDA-related hemodynamic information and PDA treatment decisions before and after introduction of TNE service. Study Design This was a retrospective cohort study at a tertiary level neonatal intensive care unit in Southwestern Ontario. We investigated two time periods: Epoch-1 (non-TNE 2013–2016) versus Epoch-2 (TNE 2018–2021). We included neonates < 32 weeks with PDA. Data on baseline clinical characteristics, PDA-related echocardiographic parameters, PDA treatment details, and relevant long-term outcomes were collected. Primary outcome was defined as PDA treatment rates and need for multiple courses. Secondary outcomes included availability of PDA hemodynamic data and neonatal mortality/morbidity (PDA-related) Results A total of 275 neonates were included. A total of 162 were assessed by conventional echocardiography in Epoch-1, whereas 113 were assessed by TNE in Epoch-2. Baseline clinical characteristics were similar. Epoch-2 had more echocardiographic assessments per patient of 2.7 (±1.8) versus 1.9 (± 1.3), p < 0.001 in Epoch1. The mean postnatal age at first echocardiographic assessment was higher in Epoch-2 (12.7 days [ ± 14.6]) than in Epoch-1 (7.9 days [ ± 10.4]), p < 0.001. Comprehensive hemodynamic assessment of PDA-related echocardiographic parameters such as PDA size, shunt pattern, effect on systemic circulation, and pulmonary circulation were higher in Epoch-2. Overall, PDA treatment rates were comparable in the two time periods. The use of multiple courses of treatment was higher in Epoch-1 than in Epoch-2 (47.8 vs. 31.7%, p = 0.047). In Epoch-1, neonates received PDA treatment earlier than in Epoch-2. Conclusion With the implementation of the TNE service, increased echocardiographic evaluations per patient were completed with availability of more comprehensive hemodynamic information about PDA. PDA treatment rates were similar in the two epochs, but need for multiple courses were less in TNE era. Key Points

12 May 2022 in American Journal of Perinatology
Verified
Journal Article
Closed access
PDF file
IFIsabel Friedmann
Isabel Friedmann
PMPatrick McNamara
Patrick McNamara
SBSoume Bhattacharya
Soume Bhattacharya
ACAnita Cheng
Anita Cheng
Objective Targeted neonatal echocardiography (TNE) is a real-time cardiac imaging modality used by a hemodynamics program to aid in diagnosis, treatment, and monitoring of neonatal cardiovascular illness. This study aimed to describe trainees' perspectives on existing hemodynamics education and perceived impacts of TNE and hemodynamics services on their education. Study Design This was a mixed quantitative and qualitative study that surveyed neonatal-perinatal medicine (NPM) fellow trainees in Canada and the United States, at programs both with and without a hemodynamics service. Results Ninety-two fellows responded to the survey, of whom 24 (26%) were enrolled in a program with an active hemodynamics service, 64 (70%) were training at a program without a hemodynamics service, and 4 (4%) were unsure. Trainees at centers with a hemodynamics service were more satisfied with their cardiovascular physiology education (91 vs. 69%, p = 0.040). Twenty-five percent of all trainees felt they do not have sufficient hemodynamics training to prepare them for independent practice. Areas of knowledge gaps were identified. Bedside teaching combined with didactic teaching was identified as useful means of teaching. Conclusion Most trainees believed that TNE and a hemodynamics service are valuable educational assets. Thoughtful curriculum design for real-time and consolidation learning, with specific emphasis on content gaps, should be considered. Key Points

9 March 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
TJTamara Jahmani
Tamara Jahmani
MMMichael Miller
Michael Miller
OSOrlando da Silva
Orlando da Silva
SBSoume Bhattacharya
Soume Bhattacharya
Minimally invasive surfactant therapy (MIST) has emerged as a preferred method of surfactant delivery. Pioneers of this technique have described the use of direct laryngoscopy (DL) for MIST. With the increasing application of video laryngoscopy (VL) for neonatal airway management, it is speculated that MIST techniques can be adapted for use with VL. Objective: To compare procedural success, operator ease of use, and complication of MIST using VL vs. MIST using DL. Methods: This was a retrospective, observational cohort study conducted at a tertiary-level neonatal intensive care unit after obtaining ethical approval. We included neonates who received MIST between 1 October 2020 and 31 October 2022. Baseline demographic characteristics, along with procedural data, were collected. Primary outcome measures included the overall procedural success rate, the need for multiple attempts, and the total number of attempts. Secondary outcome measures included the occurrence of adverse events, the need for a second dose of surfactant, and the need for intubation within 7 days of the procedure. Means and SDs, independent t-tests, frequencies, and chi-square were used as appropriate. p-values < 0.05 were considered statistically significant. Results: Of the 79 neonates included, 37 neonates received MIST via VL, while 42 received MIST via DL. The median gestational age was lower in the VL group at 29.0 weeks vs. 30.5 weeks (p = 0.011) in the DL group. The median birthweight in the VL group was 1260 g, IQR (1080, 1690), which was significantly lower than the DL group, which was 1575 g, IQR (1220, 2251), p = 0.028. Purpose-built catheter use was higher in the DL group. The overall procedural success was similar between groups. The need for multiple attempts was lower with VL in comparison to DL [4 (11%) vs. 13 (31%); p = 0.034)] at the univariate level but not significant at multivariate analysis (p = 0.131). Procedural complications, the need for a second dose of surfactant, the need for mechanical ventilation post-MIST, and operator ease of use were similar. User comments emphasized the value of VL in providing real-time visual information to confirm catheter placement and guide operators/trainees. Conclusion: Overall, in our cohort, despite VL being a more recently adapted technology used more in smaller, sicker, and more premature neonates, procedural success, complications, and operator ease of use for MIST using VL and DL were comparable. Our findings show the successful application of VL for MIST and suggest procedural advantages that might facilitate universal adoption.