SEBASTIANO MENNA

Dr. SEBASTIANO MENNA

Mater Olbia Hospital, Olbia, Sardegna, Italy
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
ADAndrea D'Aviero
Andrea D'Aviero
ARAlessia Re
Alessia Re
FCFrancesco Catucci
Francesco Catucci
DPDANILA PICCARI
DANILA PICCARI
CVClaudio Votta
Claudio Votta
GMGian Carlo Mattiucci
Gian Carlo Mattiucci
Background: Organs at risk (OARs) delineation is a crucial step of radiotherapy (RT) treatment planning workflow. Time-consuming and inter-observer variability are main issues in manual OAR delineation, mainly in the head and neck (H & N) district. Deep-learning based auto-segmentation is a promising strategy to improve OARs contouring in radiotherapy departments. A comparison of deep-learning-generated auto-contours (AC) with manual contours (MC) was performed by three expert radiation oncologists from a single center. Methods: Planning computed tomography (CT) scans of patients undergoing RT treatments for H&N cancers were considered. CT scans were processed by Limbus Contour auto-segmentation software, a commercial deep-learning auto-segmentation based software to generate AC. H&N protocol was used to perform AC, with the structure set consisting of bilateral brachial plexus, brain, brainstem, bilateral cochlea, pharyngeal constrictors, eye globes, bilateral lens, mandible, optic chiasm, bilateral optic nerves, oral cavity, bilateral parotids, spinal cord, bilateral submandibular glands, lips and thyroid. Manual revision of OARs was performed according to international consensus guidelines. The AC and MC were compared using the Dice similarity coefficient (DSC) and 95% Hausdorff distance transform (DT). Results: A total of 274 contours obtained by processing CT scans were included in the analysis. The highest values of DSC were obtained for the brain (DSC 1.00), left and right eye globes and the mandible (DSC 0.98). The structures with greater MC editing were optic chiasm, optic nerves and cochleae. Conclusions: In this preliminary analysis, deep-learning auto-segmentation seems to provide acceptable H&N OAR delineations. For less accurate organs, AC could be considered a starting point for review and manual adjustment. Our results suggest that AC could become a useful time-saving tool to optimize workload and resources in RT departments.

23 April 2018 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
APA. Piermattei
A. Piermattei
FGF. Greco
F. Greco
MGM. Grusio
M. Grusio
SMSEBASTIANO MENNA
SEBASTIANO MENNA
LAL. Azario
L. Azario
AFA. Fidanzio
A. Fidanzio

15 January 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MRMaria Rago
Maria Rago
LPLorenzo Placidi
Lorenzo Placidi
MPMattia Polsoni
Mattia Polsoni
GRGiulia Rambaldi
Giulia Rambaldi
DCDavide Cusumano
Davide Cusumano
LALuigi Azario
Luigi Azario
Purpose: To evaluate the performance of eleven Knowledge-Based (KB) models for planning optimization (RapidPlantm (RP), Varian) of Volumetric Modulated Arc Therapy (VMAT) applied to whole breast comprehensive of nodal stations, internal mammary and/or supraclavicular regions. Methods and materials: Six RP models have been generated and trained based on 120 VMAT plans data set with different criteria. Two extra-structures were delineated: a PTV for the optimization and a ring structure. Five more models, twins of the previous models, have been created without the need of these structures. Results: All models were successfully validated on an independent cohort of 40 patients, 30 from the same institute that provided the training patients and 10 from an additional institute, with the resulting plans being of equal or better quality compared with the clinical plans. The internal validation shows that the models reduce the heart maximum dose of about 2 Gy, the mean dose of about 1 Gy and the V20Gy of 1.5 Gy on average. Model R and L together with model B without optimization structures ensured the best outcomes in the 20% of the values compared to other models. The external validation observed an average improvement of at least 16% for the V5Gy of lungs in RP plans. The mean heart dose and for the V20Gy for lung IPSI were almost halved. The models reduce the maximum dose for the spinal canal of more than 2 Gy on average Conclusions: All KB models allow a homogeneous plan quality and some dosimetric gains, as we saw in both internal and external validation. Sub-KB models, developed by splitting right and left breast cases or including only whole breast with locoregional lymph nodes, have shown good performances, comparable but slightly worse than the general model. Finally, models generated without the optimization structures, performed better than the original ones.

1 March 2020 in Practical Radiation Oncology
Verified
Journal Article
Closed access
GLGianfranco Loi
Gianfranco Loi
MFMarco Fusella
Marco Fusella
CVClaudio Vecchi
Claudio Vecchi
SMSEBASTIANO MENNA
SEBASTIANO MENNA
FRFederica Rosica
Federica Rosica
CFChristian Fiandra
Christian Fiandra

25 August 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
DCDavide Cusumano
Davide Cusumano
LPLorenzo Placidi
Lorenzo Placidi
EDEmiliano D'Agostino
Emiliano D'Agostino
LBLuca Boldrini
Luca Boldrini
SMSEBASTIANO MENNA
SEBASTIANO MENNA
LALuigi Azario
Luigi Azario
Introduction Aim of this study is to dosimetrically characterize a new inorganic scintillator designed for magnetic resonance-guided radiotherapy (MRgRT) in the presence of 0.35 tesla magnetic field (B). Methods The detector was characterized in terms of signal to noise ratio (SNR), reproducibility, dose linearity, angular response, and dependence by energy, field size, and B orientation using a 6 MV magnetic resonance (MR)-Linac and a water tank. Field size dependence was investigated by measuring the output factor (OF) at 1.5 cm. The results were compared with those measured using other detectors (ion chamber and synthetic diamond) and those calculated using a Monte Carlo (MC) algorithm. Energy dependence was investigated by acquiring a percentage depth dose (PDD) curve at two field sizes (3.32 x 3.32 and 9.96 x 9.96 cm(2)) and repeating the OF measurements at 5 and 10 cm depths. Results The mean SNR was 116.3 +/- 0.6. Detector repeatability was within 1%, angular dependence was <2% and its response variation based on the orientation with respect to the B lines was <1%. The detector has a temporal resolution of 10 Hz and it showed a linear response (R-2 = 1) in the dose range investigated. All the OF values measured at 1.5 cm depth using the scintillator are in accordance within 1% with those measured with other detectors and are calculated using the MC algorithm. PDD values are in accordance with MC algorithm only for 3.32 x 3.32 cm(2)field. Numerical models can be applied to compensate for energy dependence in case of larger fields. Conclusion The inorganic scintillator in the present form can represent a valuable detector for small-field dosimetry and periodic quality controls at MR-Linacs such as dose stability, OFs, and dose linearity. In particular, the detector can be effectively used for small-field dosimetry at 1.5 cm depth and for PDD measurements if the field dimension of 3.32 x 3.32 cm(2)is not exceeded.

24 August 2019 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
DCDavide Cusumano
Davide Cusumano
LBLuca Boldrini
Luca Boldrini
SMSEBASTIANO MENNA
SEBASTIANO MENNA
STStefania Teodoli
Stefania Teodoli
EPElisa Placidi
Elisa Placidi
Marco De SpiritoMarco De Spirito
Marco De Spirito
Purpose: Magnetic resonance‐guided adaptive radiotherapy (MRgART) is considered a promising resource for pancreatic cancer, as it allows to online modify the dose distribution according to daily anatomy. This study aims to compare the dosimetric performance of a simplified optimizer implemented on a MR‐Linac treatment planning system (TPS) with those obtained using an advanced optimizer implemented on a conventional Linac.Methods: Twenty patients affected by locally advanced pancreatic cancer (LAPC) were considered. Gross tumor volume (GTV) and surrounding organ at risks (OARs) were contoured on the average 4DCT scan. Planning target volume was generated from GTV by adding an isotropic 3 mm margin and excluding overlap areas with OARs.Treatment plans were generated by using the simple optimizer for the MR‐Linac in intensity‐modulated radiation therapy (IMRT) and the advanced optimizer for conventional Linac in IMRT and volumetric modulated arc therapy (VMAT) technique. Prescription dose was 40 Gy in five fractions. The dosimetric comparison was performed on target coverage, dosimetric indicators, and low dose diffusion.Results: The simplified optimizer of MR‐Linac generated clinically acceptable plans in 80% and optimal plans in 55% of cases. The number of clinically acceptable plans obtained using the advanced optimizer of the conventional Linac with IMRT was the same of MR‐Linac, but the percentage of optimal plans was higher (65%). Using the VMAT technique, it is possible to obtain clinically acceptable plan in 95% and optimal plans in 90% of cases.The advanced optimizer combined with VMAT technique ensures higher target dose homogeneity and minor diffusion of low doses, but its actual optimization time is not suitable for MRgART.Conclusion: Simplified optimization solutions implemented in the MR‐Linac TPS allows to elaborate in most of cases treatment plans dosimetrically comparable with those obtained by using an advanced optimizer. A superior treatment plan quality is possible using the VMAT technique that could represent a breakthrough for the MRgART if the modern advancements will lead to shorter optimization times.