Mohd Rahil Hasan

Mr. Mohd Rahil Hasan


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
TBTutku Beduk
Tutku Beduk
DBDuygu Beduk
Duygu Beduk
MHMohd Rahil Hasan
Mohd Rahil Hasan
ECEmine Celik
Emine Celik
JKJürgen Kosel
Jürgen Kosel
STSuna Timur
Suna Timur
Many emerging technologies have the potential to improve health care by providing more personalized approaches or early diagnostic methods. In this review, we cover smartphone-based multiplexed sensors as affordable and portable sensing platforms for point-of-care devices. Multiplexing has been gaining attention recently for clinical diagnosis considering certain diseases require analysis of complex biological networks instead of single-marker analysis. Smartphones offer tremendous possibilities for on-site detection analysis due to their portability, high accessibility, fast sample processing, and robust imaging capabilities. Straightforward digital analysis and convenient user interfaces support networked health care systems and individualized health monitoring. Detailed biomarker profiling provides fast and accurate analysis for disease diagnosis for limited sample volume collection. Here, multiplexed smartphone-based assays with optical and electrochemical components are covered. Possible wireless or wired communication actuators and portable and wearable sensing integration for various sensing applications are discussed. The crucial features and the weaknesses of these devices are critically evaluated.

19 April 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
SSSaumitra Singh
Saumitra Singh
MHMohd Rahil Hasan
Mohd Rahil Hasan
AJAkshay Jain
Akshay Jain
Roberto PillotonRoberto Pilloton
Roberto Pilloton
JNJagriti Narang
Jagriti Narang
Lateral flow assay (LFA) is emerging as one of the most popular paper-based biosensors in the field of the diagnostic industry. LFA fills all the gaps between diagnosis and treatment as it provides beneficial qualities to users such as quick response, Point-of-care appeal, early detection, low cost, and effective and sensitive detections of various infectious diseases. These benefits increase LFA’s dependability for disease management because rapid and accurate disease diagnosis is a prerequisite for effective medication. Only 2% of overall healthcare expenditures, according to Roche Molecular Diagnostics, are spent on in vitro diagnostics, even though 60% of treatment choices are based on this data. To make LFA more innovative, futuristic plans have been outlined in many reports. Thus, this review reports on very knowledgeable literature discussing LFA and its development along with recent futuristic plans for LFA-based biosensors that cover all the novel features of the improvement of LFA. LFA might therefore pose a very significant economic success and have a significant influence on medical diagnosis.

20 December 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
MHMohd Rahil Hasan
Mohd Rahil Hasan
PSPradakshina Sharma
Pradakshina Sharma
SSShifa Shaikh
Shifa Shaikh
SSSaumitra Singh
Saumitra Singh
Roberto PillotonRoberto Pilloton
Roberto Pilloton
JNJagriti Narang
Jagriti Narang
We present, for the very first time, the fabrication and electrochemical characterization of a paper-based experimental platform for dengue virus analysis. The paper-based device incorporates a screen-printing technology with the help of black carbon conductive ink. The paper-based device utilizes two styles of electrode setups, i.e., the two-electrode system and three-electrode system, and both setups effectively detected the dengue virus with an LOD of 0.1 µg/mL; however, these paper electrodes exhibit various current ranges, and the created sensor was encompassed and compared in this research based on current response. It is observed that the three-electrode system has a substantially higher current range, ranging from 55.53 µA to 322.21 µA, as compared to the two-electrode system, which has a current range of 0.85 µA to 4.54 µA. According to this study, the three-electrode system displayed a good range of current amplification that is roughly 50 times higher than the two-electrode system, which had a weak current response. As a result, the three-electrode method has emerged as a viable option for the very sensitive detection of the dengue virus, as well as for the diagnosis of other diseases.

22 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
ABAnirudh Kumar Bishoyi
Anirudh Kumar Bishoyi
MAMd Anish Alam
Md Anish Alam
MHMohd Rahil Hasan
Mohd Rahil Hasan
MKManika Khanuja
Manika Khanuja
Roberto PillotonRoberto Pilloton
Roberto Pilloton
JNJagriti Narang
Jagriti Narang
Zika virus (ZIKV), a positive-sense single-stranded RNA virus, has been declared as the cause of a ‘worldwide public health emergency’ by the WHO since the year 2016. In cases of acute infections, it has been found to cause Guillain–Barre syndrome and microcephaly. Considering the tropical occurrence of the infections, and the absence of any proper treatments, accurate and timely diagnosis is the only way to control this infectious disease. Currently, there are many diagnostic methods under investigation by the scientific community, but they have some major limitations, such as high cost, low specificity, and poor sensitivity. To overcome these limitations, we have presented a low-cost, simple-to-operate, and portable diagnosis system for its detection by utilizing silver nanoparticles. silver nanoparticles were synthesized via chemical methods and characterization was confirmed by UV/TEM and XRD. The paper platform was synthesized using a graphene-based conductive ink, methylene blue as the redox indicator, and a portable potentiostat to perform the cyclic voltammetry to ensure true point-of-care availability for patients in remote areas.

16 July 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
PSPradakshina Sharma
Pradakshina Sharma
MHMohd Rahil Hasan
Mohd Rahil Hasan
Ubaid Mushtaq NaikooUbaid Mushtaq Naikoo
Ubaid Mushtaq Naikoo
SKShaheen Khatoon
Shaheen Khatoon
Roberto PillotonRoberto Pilloton
Roberto Pilloton
JNJagriti Narang
Jagriti Narang
Medical devices have progressed from their initial bulky forms to smart devices. However, their rigidity hampers their seamless integration into everyday life. The fields of stretchable, textile, and flexible electronics are emerging research areas with the potential to drive significant technological progress. This research presents a laboratory-based technique to produce highly sensitive and flexible biosensors for detecting the chikungunya virus. These biosensors are based on 0D nanomaterials and demonstrate significant advancements in voltammetry. The electrochemical platform was created utilizing the stencil printing (StPE) technique. Adapting the biosensor setup involved the selection of aptamer as the biorecognition element bound with silver nanoparticles (AgNPs). This biosensor was employed in the voltammetric identification of the Chikungunya virus antigen (CHIKV-Ag) within a solution containing 0.5 mM potassium ferro/ferri cyanide, a redox pair. The biosensor was employed to evaluate CHIKV-Ag within a human serum sample. It demonstrated a linear detection span ranging from 0.1 ng/mL to 1 μg/mL, with a detection limit of 0.1 ng/mL for CHIKV-Ag. The proposed approach, due to its flexibility in production and the electrocatalytic attributes displayed by the zero-dimensional nanostructure, presents innovative opportunities for cost-effective and tailored aptamer-based bioelectronics, thereby broadening the scope of this domain.

25 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MHMohd Rahil Hasan
Mohd Rahil Hasan
SSSaumitra Singh
Saumitra Singh
PSPradakshina Sharma
Pradakshina Sharma
CRChhaya Rawat
Chhaya Rawat
MKManika Khanuja
Manika Khanuja
JNJagriti Narang
Jagriti Narang
There is currently a lot of interest in the construction of point-of-care devices stemming from paper-based origami biosensors. These devices demonstrate how paper’s foldability permits the construction of sensitive, selective, user-friendly, intelligent, and maintainable analytical devices for the detection of several ailments. Herein, the first example of the electrochemical aptasensor-based polyvalent dengue viral antigen detection using the origami paper-folding method is presented. Coupling it with an aptamer leads to the development of a new notation known as OBAs, or origami-based aptasensor, that presents a multitude of advantages to the developed platform, such as assisting in safeguarding the sample from air-dust particles, providing confidentiality, and providing a closed chamber to the electrodes. In this paper, gold-decorated nanocomposites of zinc and graphene oxide (Au/ZnO/GO) were synthesized via the chemical method, and characterization was conducted by Scanning Electron Microscope, Transmission Electron Microscope, UV-Vis, and XRD which reveals the successful formation of nanocomposites, mainly helping to enhance the signal and specificity of the sensor by employing aptamers, since isolation and purification procedures are not required. The biosensor that is being demonstrated here is affordable, simple, and efficient. The reported biosensor is an OBA detection of polyvalent antigens of the dengue virus in human serum, presenting a good range from 0.0001 to 0.1 mg/mL with a limit of detection of 0.0001 mg/mL. The reported single-folding ori-aptasensor demonstrates exceptional sensitivity, specificity, and performance in human serum assays, and can also be used for the POC testing of various viral infections in remote areas and underdeveloped countries, as well as being potentially effective during outbreaks. Highlights: (1) First report on origami-based aptasensors for the detection of polyvalent antigens of DENV; (2) In-house construction of low-cost origami-based setup; (3) Gold-decorated zinc/graphene nanocomposite characterization was confirmed via FESEM/UV-Vis/FTIR; (4) Cross-reactivity of dengue-aptamer has been deduced; (5) Electrochemical validation was conducted through CV.