23 September 2023 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
CACornelia Amstutz
Cornelia Amstutz
JBJean-Marc Behr
Jean-Marc Behr
SKS. Krebs
S. Krebs
AHAndreas Haeberlin
Andreas Haeberlin
RVR. Vogel
R. Vogel
JBJuergen Burger
Juergen Burger
Background: Eight commercially available percutaneous transluminal coronary angioplasty (PTCA), including semi-compliant and non-compliant balloons, have been assessed in detail on their tip, balloon, shaft, RX-Port, and hypotube design. Important performance characteristics such as tip deformation, balloon elongation, and deflation rate have been quantified. Methods: Five catheters of each model were evaluated during various tests. The robustness of the tips was evaluated through compression, measuring any occurrence of damage. The longitudinal growth of the balloons was recorded during inflation up to Rated Burst Pressure (RBP). The forces required to move the catheter forward and retract it into the guide catheter were measured in a simulated use test setup. The deflation behavior was studied by measuring extracted contrast media over time. Furthermore, balloon compliance and catheter dimensions were investigated. Results: The outer dimensions of the catheter were found to be smallest at the hypotube (0.59–0.69 mm) and highest at the balloon, respectively, the crossing profile (0.9–1.2 mm). The tip diameter increased after compression by 1.7–22%. Cross-sections of the folded balloons revealed a tri- and two-fold, respectively. The measured balloon elongation ranged from 0.6 to 2.0 mm. After the inflation of the balloon, an increase in friction between the guide wire and the catheter was observed on four catheters. A maximum increase of 0.12 N to 1.07 N was found. Cross-sections of the RX-Port revealed a semicircular-shaped inflation lumen and a circular guide wire lumen. The measured deflation rate ranged from 0.004 to 0.013 µL/s, resulting in an estimated balloon deflation time of 10.2–28.1 s. Conclusion: This study provides valuable insights into the design characteristics of RX PTCA balloon catheters, which can contribute to facilitating the development of improved catheter designs and enhancing clinical outcomes. Distinctions between SC and NC catheters, such as balloon performance and dimensions, are evident. It is important to note that no single catheter excels in all aspects, as each possesses unique strengths. Therefore, it is essential to consider individual intervention requirements when selecting a catheter. The research also identifies specific catheter weaknesses, such as reduced wall thickness, fringes at the tip, and reduced performance characteristics.

26 October 2021 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
CACornelia Amstutz
Cornelia Amstutz
BWBernhard Weisse
Bernhard Weisse
SVS. Valet
S. Valet
AHAndreas Haeberlin
Andreas Haeberlin
JBJuergen Burger
Juergen Burger
AZAdrian Zurbuchen
Adrian Zurbuchen
Background: Percutaneous transluminal coronary angioplasty (PTCA) balloon catheters must withstand high pressures required for the lesion treatment, pushing loads during insertion, and pulling loads during withdrawal. These loads pose a challenge especially for polymeric tubular shafts with small cross sections. In order to enable new design innovations and to better understand the mechanics of current catheter technologies, the tensile properties of polyamide (PA) 12 were investigated. PA 12 dog bone specimens and medical PA 12 tubes were either stored at ambient temperature and humidity or conditioned in water, and subjected to tensile loads at different temperatures. In addition, the effect on the tensile properties of the necking process, a forming process to reduce the wall thickness of the tubes, was determined. Results: The tested tubes showed a reduction in both Young’s Modulus (− 41.5%) and yield stress (− 29.2%) compared to standardized specimens. Furthermore, an increase in temperature and water absorption softens the material and reduces the mechanical properties like the Young’s Modulus and the yield stress. It was found that the material strengthens during the necking process. Likely due to the orientation of the polymers chain molecules in load direction (Rösler et al., 2007), the Young’s Modulus of the material could be increased by 43.5%. Furthermore, the absence of a yield point after necking allows for a greater loading capacity of the material without unstable neck growth. Besides the strengthening, the ultimate strain is reduced by 50%. This indicates that the necking process induces plastic deformation. Conclusion: The investigation showed that the environmental conditions like temperature and humidity can influence mechanical properties. It could also be shown that pre-forming processes such as necking can enhance the mechanical properties, such as the Young’s Modulus, while reducing the wall thickness. These findings suggest possible further development of catheters with a small cross section and higher mechanical strength and highlight the importance to account for the targeted operating temperature during the design process.

25 August 2022 in Polymers
Verified
Journal Article
Open access
PDF file
CACornelia Amstutz
Cornelia Amstutz
BWBernhard Weisse
Bernhard Weisse
AHAndreas Haeberlin
Andreas Haeberlin
JBJuergen Burger
Juergen Burger
AZAdrian Zurbuchen
Adrian Zurbuchen
Finite-element (FE) simulations that go beyond the linear elastic limit of materials can aid the development of polymeric products such as stretch blow molded angioplasty balloons. The FE model requires the input of an appropriate elastoplastic material model. Up to the onset of necking, the identification of the hardening curve is well established. Subsequently, additional information such as the cross-section and the triaxial stress state inside the specimen is required. The present study aims to inversely identify the post-necking hardening behavior of the semi-crystalline polymer polyamide 12 (PA12) at different temperatures. Our approach uses structural FE simulations of a dog-bone tensile specimen in LS-DYNA with mesh sizes of 1 mm and 2 mm, respectively. The FE simulations are coupled with an optimization routine defined in LS-OPT to identify material properties matching the experimental behavior. A Von Mises yield criterion coupled with a user-defined hardening curve (HC) were considered. Up to the beginning of necking, the Hockett–Sherby hardening law achieved the best fit to the experimental HC. To fit the entire HC until fracture, an extension of the Hockett–Sherby law with power-law functions achieved an excellent fit. Comparing the simulation and the experiment, the following coefficient of determination R2 could be achieved: Group I: R2 > 0.9743; Group II: R2 > 0.9653; Group III: R2 > 0.9927. Using an inverse approach, we were able to determine the deformation behavior of PA12 under uniaxial tension for different temperatures and mathematically describe the HC.

30 August 2024 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
CACornelia Amstutz
Cornelia Amstutz
MIM. Ilic
M. Ilic
NFN. Fontaine
N. Fontaine
LSL. Siegenthaler
L. Siegenthaler
JIJ. Illi
J. Illi
JBJ. Burger
J. Burger
Background: To treat stenosed coronary arteries, percutaneous transluminal coronary angioplasty (PTCA) balloon catheters must combine pushability, trackability, crossability, and rewrap behavior. The existing anatomic track model (ASTM F2394) for catheter testing lacks 3D morphology, vessel tortuosity, and compliance, making evaluating performance characteristics difficult. This study aimed to develop a three-dimensional patient-specific phantom (3DPSP) for device testing and safe training for interventional cardiologists. Methods: A range of silicone materials with different shore hardnesses (00–30–45 A) and wall thicknesses (0.5 mm, 1 mm, 2 mm) were tested to determine compliance for creating coronary vessel phantoms. Compliance was assessed using optical coherence tomography (OCT) and compared to values in the literature. Stenosis was induced using multilayer casting and brushing methods, with gypsum added for calcification. The radial tensile properties of the samples were investigated, and the relationship between Young’s modulus and compliance was determined. Various methods have been introduced to approximate the friction between silicone and real coronary vessel walls. Computerized tomography (CT) scans were used to obtain patient-specific anatomy from the femoral artery to the coronary arteries. Artery lumens were segmented from the CT scans to create dissolvable 3D-printed core models. Results: A 15A shore hardness silicone yielded an experimental compliance of 12.3–22.4 $$\frac{m{m}^{2}}{mmHg}\cdot {10}^{3}$$ m m 2 mmHg · 10 3 for stenosed tubes and 14.7–57.9 $$\frac{m{m}^{2}}{mmHg}\cdot {10}^{3}$$ m m 2 mmHg · 10 3 for uniform tubes, aligning closely with the literature data (6.28–40.88 $$\frac{m{m}^{2}}{mmHg}\cdot {10}^{3}$$ m m 2 mmHg · 10 3 ). The Young’s modulus ranged from 43.2 to 75.5 kPa and 56.6–67.9 kPa for the uniform and calcified materials, respectively. The dependency of the compliance on the wall thickness, Young’s modulus, and inner diameter could be shown. Introducing a lubricant reduced the silicone friction coefficient from 0.52 to 0.13. The 3DPSP was successfully fabricated, and comparative analyses were conducted among eight commercially available catheters. Conclusion: This study presents a novel method for crafting 3DPSPs with realistic mechanical and frictional properties. The proposed approach enables the creation of comprehensive and anatomically precise setups spanning the right femoral artery to the coronary arteries, highlighting the importance of such realistic environments for advancing medical device development and fostering safe training conditions.

22 March 2026 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
CACornelia Amstutz
Cornelia Amstutz
MHMario Hersberger
Mario Hersberger
NFN. Fontaine
N. Fontaine
JBJean-Marc Behr
Jean-Marc Behr
AHAndreas Haeberlin
Andreas Haeberlin
JBJuergen Burger
Juergen Burger
Purpose: This paper aims to categorize the mechanical properties of eight percutaneous transluminal coronary angioplasty (PTCA) balloon catheters and translate them into clinical needs. Method: Objective bench tests quantified PTCA balloon catheters' mechanical properties, including tensile strength, kink resistance, bending, torsional behavior, friction, radio-opacity, pushability, and trackability. The results were compared against each other and supplemented by a survey of interventional cardiologists. Results: Clinical needs with respect to deliverability, dilatation efficiency, and crossability were assessed for each catheter. Results indicate that SC Maverick2 excels in deliverability and crossability but lags in dilatation efficiency compared to NC catheters, though it is rated best to fulfill clinical needs. SC EasyT outperforms Maverick2 in dilatation efficiency but has inferior deliverability, similar to NC catheters. The NC balloons were comparable. However, Accuforce exhibits highest deliverability, Pantera LEO shows superior dilatation efficiency, NC Emerge shows best crossability, and Sapphire NC24 exhibits lowest performance. According to the survey, Accuforce, Sapphire NC24, and NC Trek are favored over NC Emerge and Pantera LEO. OPN NC offers limited deliverability but can treat lesions where standard NC catheters fail due to its unique rated burst pressure. Trackability and pushability estimates align better with survey results than those obtained from simulated use-case tests, except for Sapphire NC24 and OPN NC. Torquability measurements show discrepancies with survey ratings, indicating additional influences and rating challenges. Conclusion: Our study comprehensively analyzes PTCA balloon catheters, emphasizing the importance of integrating mechanical and design attributes throughout development. Performance properties like trackability and pushability were measured, providing unbiased insights for comparison independent of individual practitioner preferences.