Abayomi Baruwa

Dr. Abayomi Baruwa

Faculdade de Medicina Dentária da Universidade de Lisboa, Lisbon, Lisboa, Portugal
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of Endodontics
Verified
Journal Article
Closed access
Abayomi BaruwaAbayomi Baruwa
Abayomi Baruwa
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
JMJoão Meirinhos
João Meirinhos
BPBeatriz Pereira
Beatriz Pereira
JGJosé Gouveia
José Gouveia
Antonio GinjeiraAntonio Ginjeira
Antonio Ginjeira

20 November 2019 in International Endodontic Journal
Verified
Journal Article
Closed access
PDF file
JMJ. Meirinhos
J. Meirinhos
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
BPB. Pereira
B. Pereira
Abayomi BaruwaAbayomi Baruwa
Abayomi Baruwa
JGJ. Gouveia
J. Gouveia
Antonio GinjeiraAntonio Ginjeira
Antonio Ginjeira

23 November 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Abayomi BaruwaAbayomi Baruwa
Abayomi Baruwa
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
Tatjana MaravicTatjana Maravic
Tatjana Maravic
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
Annalisa MazzoniAnnalisa Mazzoni
Annalisa Mazzoni
Antonio GinjeiraAntonio Ginjeira
Antonio Ginjeira
Irrigating solutions play an important role in the eradication of intracanal microbes and debris dissolution during endodontic treatment. Different combinations of solutions and protocols have been advocated, with sodium hypochlorite (NaOCl), ethylenediamine tetra acetic acid (EDTA), and chlorhexidine (CHX) remaining the most widely used ones by many clinicians. Although these solutions provide efficient inorganic dissolution and antimicrobial capacity, their use has also been reported to cause undesired effects on root dentin composition and mechanical and biomechanical properties, such as microhardness, surface roughness, bond strength, and matrix metalloproteinase (MMP) activity. Several corroborating studies attribute these changes in mechanical properties of dentine to the use of irrigating solutions, and there are limited reports on how the solutions affect the expression of MMPs, which may be a correlating link to understanding the role of these enzymes in dentin collagen and changes in the mechanical properties of dentin. Hence, using the basis of several studies from the literature, the objective is to comprehensively review the influence of individual and combined irrigating solutions on root dentine structure and the activity of the MMPs.

1 June 2020 in Journal of Endodontics
Verified
Journal Article
Closed access
BPBeatriz Pereira
Beatriz Pereira
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
Abayomi BaruwaAbayomi Baruwa
Abayomi Baruwa
JMJoão Meirinhos
João Meirinhos
JGJosé Gouveia
José Gouveia
Antonio GinjeiraAntonio Ginjeira
Antonio Ginjeira

19 April 2023 in International Endodontic Journal
Verified
Journal Article
Open access
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
ESEmmanuel Silva
Emmanuel Silva
Abayomi BaruwaAbayomi Baruwa
Abayomi Baruwa
RCRui Pereira da Costa
Rui Pereira da Costa
FFFrancisco M. Braz Fernandes
Francisco M. Braz Fernandes
MVMarco Versiani
Marco Versiani
Aim: To compare two flat‐side single‐file rotary instruments with three single‐file reciprocating systems through a multimethod assessment.Methodology: A total of 290 new NiTi single‐file rotary (AF F One Blue 25/0.06 and Platinum V.EU 25/0.06) and reciprocating (One Files Blue R25, Reciproc Blue R25, Reciproc R25) instruments were selected, carefully examined for any major deformations, and evaluated regarding their macroscopic and microscopic design, nickel and titanium elements ratio, phase transformation temperatures, and mechanical performance (time/rotation to fracture, maximum torque, angle of rotation, microhardness, maximum bending, and buckling strengths). One‐way anova post hoc Tukey, T‐test, and nonparametric Mood's median tests were used for statistical comparisons (α = 5%).Results: Tested instruments had identical blade counts and near‐identical helical angles of approximately 24° (rotary instruments) and 151° (reciprocating instruments). The flat‐side analysis revealed a few inconsistencies, such as discontinuity segments, different orientations, and gaps in the homogeneity of the bluish colour. Microscopically, flat‐side instruments exhibited blade discontinuity and an incomplete S‐shaped cross‐section. The surface finish was smoother for One Files Blue and more irregular for both rotary instruments. There were distinct phase transformation temperatures amongst all instruments. All heat‐treated instruments were in R‐phase arrangement, and Reciproc was in R‐phase plus austenite at test temperature (20°C). Compared with the reciprocating instruments, both flat‐side instruments exhibited lower results in the cyclic fatigue tests using two different clockwise kinematics, maximum torque, angle of rotation, and maximum buckling strength (p < .05). The rotary systems also exhibited low flexibility (p < .05). AF F One Blue had the lowest microhardness, whilst Reciproc had the highest value.Conclusion: This multimethod investigation revealed that the flat‐side rotary instruments underperformed the reciprocating instruments regarding cyclic fatigue (with two different clockwise kinematics), maximum torque, angle of rotation, maximum buckling strength, and flexibility. Manufacturing inconsistencies were also observed in some of the flat‐side instruments, including discontinuity segments, different orientations, and in the homogeneity of their bluish colour given by the heat treatment.

12 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
ESEmmanuel Silva
Emmanuel Silva
Duarte MarquesDuarte Marques
Duarte Marques
Abayomi BaruwaAbayomi Baruwa
Abayomi Baruwa
João Manuel Mendes CaramesJoão Manuel Mendes Carames
João Manuel Mendes Carames
MVMarco Versiani
Marco Versiani
This article aims to explore the importance of multimethod research in assessing the performance of nickel-titanium (NiTi) endodontic instruments. The review highlights the limitations of relying solely on measurements obtained through a narrow set of mechanical tests and acknowledges the challenge of replicating real-world working conditions in controlled laboratory settings. While achieving a perfect simulation may be difficult, the focus should be on developing research strategies that provide a superior understanding of outcomes. The multimethod research, which combines qualitative and quantitative methodologies, offers a promising solution to address this challenge effectively. By integrating nonquantifiable data with quantitative measurements, researchers may overcome the limitations of individual methodologies and gain deeper and more comprehensive insights into instrument performance. This multimethod approach enables a more accurate interpretation of results, enhancing the validity of the methodology. Therefore, conducting a comprehensive analysis of various competencies displayed by NiTi systems is essential for a comprehensive understanding of their characteristics, including cyclic fatigue, torsional and bending resistance, cutting efficiency, microhardness, design analysis, element composition, phase transformation temperatures, shaping ability, and additional methodologies that can address specific inquiries. By combining qualitative and quantitative methodologies in a multimethod approach, researchers can enhance their ability to answer research questions and provide valuable insights for clinical practice.