Claudia Mazzitelli

Dr. Claudia Mazzitelli

DIBINEM – University of Bologna, Bologna (Italy)
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Gaetano PaoloneGaetano Paolone
Gaetano Paolone
MMMauro Mandurino
Mauro Mandurino
FPFrancesca De Palma
Francesca De Palma
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
Nicola ScottiNicola Scotti
Nicola Scotti
Alessandro VichiAlessandro Vichi
Alessandro Vichi
Background: This systematic review aims to evaluate the color stability of resin composite CAD/CAM blocks (CCB) when submitted to staining solutions. Methods: A systematic search was performed on different databases (Embase, Medline, Scopus, Web of Science). Search terms were: ‘polymer infiltrated’, ‘polymer-based’, ‘resin nanoceramic’, ‘resin ceramic’, ‘hybrid composite’, ‘hybrid ceramic’, ‘composite ceramic’, ‘resin infiltrated’, ‘CAD-CAM’, ‘CAD/CAM’, ‘color stability’, ‘staining’, ‘staining susceptibility’, ‘color change’, ‘color difference’. Inclusion criteria: in vitro articles published in the English language until 18 September 2022 without initial time restriction evaluating the color stability of CCB when submitted to staining solutions. Exclusion criteria: studies investigating color change induced by smoke or whitening treatments; studies not including a clinical evaluation of the results using the thresholds for color perceptibility and acceptability. Risk of bias assessment using the QUIN tool. Findings: Out of the 378 initially retrieved articles, 19 were included in this review. They investigated 17 different CCBs and different artificial staining by liquid protocols, including coffee, red wine, tea, and cola. CCBs exceeded clinical acceptability thresholds for color shift in 18 out of 19 studies, with a significantly higher color stability than conventional hybrid resin-based composites (RBCs), and a significantly lower color stability than ceramic materials. The identified differences in CCBs in color stability can be attributed to the material’s composition, but also to the heterogeneity of staining procedures. Interpretation and clinical implication: Clinicians should be aware that, although to a lower degree when compared to RBCs used in direct or indirect procedures, CCBs undergo color changes to a higher degree in comparison to ceramic materials.

23 November 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Abayomi BaruwaAbayomi Baruwa
Abayomi Baruwa
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
Tatjana MaravicTatjana Maravic
Tatjana Maravic
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
Annalisa MazzoniAnnalisa Mazzoni
Annalisa Mazzoni
Antonio GinjeiraAntonio Ginjeira
Antonio Ginjeira
Irrigating solutions play an important role in the eradication of intracanal microbes and debris dissolution during endodontic treatment. Different combinations of solutions and protocols have been advocated, with sodium hypochlorite (NaOCl), ethylenediamine tetra acetic acid (EDTA), and chlorhexidine (CHX) remaining the most widely used ones by many clinicians. Although these solutions provide efficient inorganic dissolution and antimicrobial capacity, their use has also been reported to cause undesired effects on root dentin composition and mechanical and biomechanical properties, such as microhardness, surface roughness, bond strength, and matrix metalloproteinase (MMP) activity. Several corroborating studies attribute these changes in mechanical properties of dentine to the use of irrigating solutions, and there are limited reports on how the solutions affect the expression of MMPs, which may be a correlating link to understanding the role of these enzymes in dentin collagen and changes in the mechanical properties of dentin. Hence, using the basis of several studies from the literature, the objective is to comprehensively review the influence of individual and combined irrigating solutions on root dentine structure and the activity of the MMPs.

25 March 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Uros JosicUros Josic
Uros Josic
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
Tatjana MaravicTatjana Maravic
Tatjana Maravic
AFAleš Fidler
Aleš Fidler
Lorenzo BreschiLorenzo Breschi
Lorenzo Breschi
AFAleš Fidler
Aleš Fidler
Incomplete and inadequate removal of endodontic biofilm during root canal treatment often leads to the clinical failure. Over the past decade, biofilm eradication techniques, such as sonication of irrigant solutions, ultrasonic and laser devices have been investigated in laboratory settings. This review aimed to give an overview of endodontic biofilm cultivation methods described in papers which investigated sonic-, ultrasonic- and Er:Yag laser-assisted biofilm removal techniques. Furthermore, the effectiveness of these removal techniques was discussed, as well as methods used for the evaluation of the cleaning efficacy. In general, laser assisted agitation, as well as ultrasonic and sonic activation of the irrigants provide a more efficient biofilm removal compared to conventional irrigation conducted by syringe/needle. The choice of irrigant is an important factor for reducing the bacterial contamination inside the root canal, with water and saline being the least effective. Due to heterogeneity in methods among the reviewed studies, it is difficult to compare sonic-, ultrasonic- and Er:Yag laser-assisted techniques among each other and give recommendations for the most efficient method in biofilm removal. Future studies should standardize the methodology regarding biofilm cultivation and cleaning methods, root canals with complex morphology should be introduced in research, with the aim of simulating the clinical scenario more closely.

24 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
Gaetano PaoloneGaetano Paolone
Gaetano Paolone
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
Uros JosicUros Josic
Uros Josic
Nicola ScottiNicola Scotti
Nicola Scotti
GEGherlone Felice Enrico
Gherlone Felice Enrico
Lorenzo BreschiLorenzo Breschi
Lorenzo Breschi
Several lubricant materials can be used to model resin-based composites (RBCs) during restorative procedures. Clinically, instruments or brushes are wet with bonding agents (BAs) or modeling liquids (MLs) for sculpturing purposes. However, a knowledge gap exists on their effects on the mechanical properties of RBCs, requiring greater insight. Five databases were searched, including 295 in vitro studies on the use of lubricant materials for modeling RBCs during restorative procedures. Only articles in the English language were included, with no limits on the publication date. The last piece of research was dated 24 March 2022. In total, 16 studies were included in the review process, together with a paper retrieved after screening references. A total of 17 BAs and 7 MLs were investigated. Tensile (n = 5), flexural strength (n = 2), water sorption (n = 2), color stability (n = 8) and translucency (n = 3), micro-hardness (n = 4), roughness (n = 3), degree of conversion (n = 3), and monomer elution (n = 2) tests were carried out. In general, a maximum of 24 h of artificial storage was performed (n = 13), while four papers tested the specimens immediately. The present review identifies the possibilities and limitations of modeling lubricants used during restorative procedures on the mechanical, surface, and optical properties of RBCs. Clinicians should be aware that sculpturing RBCs with modeling resins might influence the composite surface properties in a way that is material-dependent.

27 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
Gaetano PaoloneGaetano Paolone
Gaetano Paolone
JSJoseph Sabbagh
Joseph Sabbagh
Nicola ScottiNicola Scotti
Nicola Scotti
Alessandro VichiAlessandro Vichi
Alessandro Vichi
The color stability of resin cements plays a key role in the achievement of esthetically-pleasant restorations. Resin luting materials can be mainly divided into two main classes: adhesive (relying on previous application of adhesive systems) or self-adhesive (also known as one-step cements). The different chemical compositions determine their physio-mechanical characteristics which, in turns, influence their color stability. To evaluate the color variations of different dual-cured resin cements after water aging, 80 disc-shaped specimens (15 mm in diameter and 1.2 mm thick) were obtained from the following resin cements (n = 10): (1) Maxcem Elite Universal, MCU (Kerr); (2) RelyX Universal, RXU (3M); (3) Calibra Ceram, CAL (Dentsply); (4) Multilink, MUL (Ivoclar-Vivadent); (5) Panavia V5, PAN (Kuraray); (6) Calibra Universal, CUN (Dentsply); (7) SpeedCEM Plus, SCP (Ivoclar); and (8) Panavia SA, PSA (Kuraray). After light-polymerization, the specimens were measured with a spectrophotometer and CIELab* values were recorded. The specimens were then placed in a digitally controlled thermostatic water bath at 60° for 30 days and afterwards the color measurements were repeated. Color differences were calculated for each specimen before and after water-aging procedures with ΔEab formula and the data were statistically analyzed (p < 0.05). The type of cement statistically influenced the ΔEab (p < 0.05), with MCU showing the lowest color variations (4.3 ± 0.7) whereas RXU and PSA the highest (16.9 ± 1.6 and 16.8 ± 1.2, respectively). No differences were observed between CAL, CUN and SCP (p = 0.05). Color stability is related to the chemical composition of the resinous luting materials, thus material dependent.

5 October 2024 in Journal of Dentistry
Verified
Journal Article
Closed access
CDCarlo D'Alessandro
Carlo D'Alessandro
UJUros Josic
Uros Josic
Claudia MazzitelliClaudia Mazzitelli
Claudia Mazzitelli
Tatjana MaravicTatjana Maravic
Tatjana Maravic
LGLaurel Graham
Laurel Graham
BBBlatz Markus Bernhard
Blatz Markus Bernhard