Zircon water content is an important physicochemical parameter for many geological processes, yet its measurement by the secondary ion mass spectrometry (SIMS) technique is hampered by the lack of suitable reference materials and high water background, especially if large-geometry (LG)-SIMS is used. Here we have described a suite of newly developed reference materials for SIMS zircon water content analysis and a modified micro-analytical technique (using a CAMECA IMS 1280-HR SIMS) that can simultaneously measure the zircon water content and oxygen isotopes. A total of 20 natural zircon grains/sherds were analyzed via Fourier transform infrared spectroscopy (FTIR), among which 8 (with good water content result reproducibility) were further analyzed by SIMS. Before the SIMS analysis, FTIR analyzed sample blocks were mounted with a Sn-based alloy to minimize degassing and background water. As in routine SIMS oxygen isotope measurement, 16O− and 18O− were collected using two Faraday cups, and in addition 16O1H− was simultaneously measured using an electron multiplier. The measured 16O1H/6O ratio was converted into water content, using a calibration line established based on SIMS 16O1H−/16O− ratios vs. the FTIR water content. Both the internal and external precisions of corrected δ18O are <0.4 permil (2SE or 2SD). The internal precision of 16O1H−/16O− ratios follows a Poisson error theoretical trend and is generally better than 0.3%. The external precision (reproducibility) of 16O1H−/16O− ratios is better than 5% (2SD) for homogenous samples, and uncertainty of the calibrated water content is ∼10%.
7 June 2018 in Journal of Analytical Atomic Spectrometry
Secondary ion mass spectrometry (SIMS) has been applied to analyze a wide range of materials for earth science research due to its high sensitivity, high precision and capacity for in situ micro-analysis. This technique operates under ultra-high vacuum (UHV) conditions, especially for water content measurements on nominally anhydrous minerals (NAMs). However, UHV conditions are hard to achieve when using epoxy mounts, which degas readily during the vacuum processes. In this study, we developed a novel sample preparation method using a tin-based alloy instead of epoxy resin. Using a tin alloy mount coupled with an automatic liquid nitrogen refilling system, the results show that the vacuum conditions have been significantly improved from ∼1.2 × 10−8 mbar to ∼1.9 × 10−9 mbar. The background for mineral water content, measured with a CAMECA IMS 1280-HR SIMS installed at the Guangzhou Institute of Geochemistry, Chinese Academy of Sciences (GIGCAS), is lowered to <10 ppm. Moreover, tin alloy mounts are harder and easier to polish than indium mounts, which was commonly used for previous UHV analyses. A relief of <2 μm is yielded for tin alloy mounts, which is essential for high precision isotope analysis. Our results also show that the routine external precision of oxygen isotope ratios is better than 0.15‰ (1SD), comparable with that obtained using epoxy mounts.
12 December 2019 in Surface and Interface Analysis