Sara Thrower

Dr. Sara Thrower

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2017 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Open access
PDF file
KMK. B. Mathieu
K. B. Mathieu
DBD. G. Bedi
D. G. Bedi
STSara Thrower
Sara Thrower
AQA. Qayyum
A. Qayyum
RBR. C. Bast
R. C. Bast
Click on the article title to read more.

1 July 2021 in Advances in Radiation Oncology
Verified
Journal Article
Open access
STSara Thrower
Sara Thrower
KFKarine A. Al Feghali
Karine A. Al Feghali
DLDershan Luo
Dershan Luo
IPIan Paddick
Ian Paddick
PHPing Hou
Ping Hou
CCCaroline Chung
Caroline Chung
Stereotactic radiosurgery is a common treatment for brain metastases and is typically planned on magnetic resonance imaging (MRI). However, the MR acquisition parameters used for patient selection and treatment planning for stereotactic radiosurgery can vary within and across institutions. In this work, we investigate the effect of MRI slice thickness on the detection and contoured volume of metastatic lesions in the brain. A retrospective cohort of 28 images acquired with a slice thickness of 1 mm were resampled to simulate acquisitions at 2- and 3-mm slice thickness. A total of 102 metastases ranging from 0.0030 cc to 5.08 cc (75-percentile 0.36 cc) were contoured on the original images. All 3 sets of images were recontoured by experienced physicians. Of all the images detected and contoured on the 1 mm images, 3% of lesions were missed on the 2 mm images, and 13% were missed on the 3 mm images. One lesion that was identified on both the 2 mm and 3 mm images was determined to be a blood vessel on the 1 mm images. Additionally, the lesions were contoured 11% larger on the 2 mm and 43% larger on the 3 mm images. Using images with a slice thickness >1 mm effects detection and segmentation of brain lesions, which can have an important effect on patient management and treatment outcomes.

1 August 2016 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
STSara Thrower
Sara Thrower
SSSimona F. Shaitelman
Simona F. Shaitelman
EBElizabeth Bloom
Elizabeth Bloom
MSMohammad Salehpour
Mohammad Salehpour
KGKent Gifford
Kent Gifford

8 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
STSara Thrower
Sara Thrower
SPSurendra Prajapati
Surendra Prajapati
SHShannon Holmes
Shannon Holmes
ESEmil Schüler
Emil Schüler
Sam BeddarSam Beddar
Sam Beddar
(1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion chambers designed for small field measurements. (2) Methods: We measured beam profiles and percent depth dose curves with each detector and investigated the linearity of each system based on dose per pulse (DPP) and pulse repetition frequency. (3) Results: We found excellent agreement between the W2 scintillator and the ion chambers for beam profiles and percent depth dose curves. Our results also showed that the two-voltage method of calculating the ion recombination correction factor was sufficient to correct for the ion recombination effect of ion chambers, even at the highest DPP. (4) Conclusions: These findings show that the W2 scintillator shows excellent agreement with ion chambers in high DPP conditions.

2 April 2025 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
KHKhushi C. Hiremath
Khushi C. Hiremath
KAKenan Atakishi
Kenan Atakishi
ELErnesto Augusto Bueno da Fonseca Lima
Ernesto Augusto Bueno da Fonseca Lima
MFMaguy Farhat
Maguy Farhat
BPBikash Panthi
Bikash Panthi
DIDavid A. Hormuth, II
David A. Hormuth, II
We have developed a family of biology-based mathematical models of high-grade glioma (HGG), capturing the key features of tumour growth and response to chemoradiation. We now seek to quantify the accuracy of parameter estimation and determine, when given a virtual patient cohort, which model was used to generate the tumours. In this way, we systematically test both the parameter and model identifiability. Virtual patients are generated from unique growth parameters whose growth dynamics are determined by the model family. We then assessed the ability to recover model parameters and select the model used to generate the tumour. We then evaluated the accuracy of predictions using the selected model at four weeks post-chemoradiation. We observed median parameter errors from 0.04% to 72.96%. Our model selection framework selected the model that was used to generate the data in 82% of the cases. Finally, we predicted the growth of the virtual tumours using the selected model resulting in low error at the voxel-level (concordance correlation coefficient (CCC) ranged from 0.66 to 0.99) and global level (percentage error in total tumour cellularity ranged from −12.35% to 0.07%). These results demonstrate the reliability of our framework to identify the most appropriate model under noisy conditions expected in the clinical setting. This article is part of the theme issue 'Uncertainty quantification for healthcare and biological systems (Part 2)'.

28 January 2026 in JNCI Cancer Spectrum
Verified
Journal Article
Open access
KKKelly Kisling
Kelly Kisling
SMSandra M Meyers
Sandra M Meyers
RMRebecca Milman
Rebecca Milman
SRSusan Richardson
Susan Richardson
CCChristina Chapman
Christina Chapman
STSara Thrower
Sara Thrower
Cancer occurs in ∼1 per 1000 pregnancies; thousands of patients may require radiation procedures for diagnosis and treatment each year in the United States alone. This rare but high-risk scenario, coupled with fear of radiation, has created ambiguity in the ideal management of pregnant patients. Without a comprehensive guide for the use of radiation in imaging and treatment for pregnant cancer patients, it is difficult for providers to offer optimal patient-centered care without introducing disparities. The goal of this paper is to provide guidance on the use of radiation for screening, diagnosis, staging, and treatment of cancer, while highlighting gaps in existing knowledge and guidelines. The intention is that physicians, medical physicists, and patients could use this document as a resource for shared decision-making, ensuring safe and effective practice. A team of physicians and medical physicists with expertise in imaging, radiotherapy, and maternal fetal medicine was assembled, along with a patient advocate and lawyer. Existing guidelines and recent literature were reviewed. Authors also drew from their experience where published guidance was lacking. The resulting document discusses best practice to guide use of radiation for cancer, as well as patient-centered care management and legal considerations. Overall, it is possible to safely and effectively deliver radiation to pregnant patients in numerous circumstances. Use of radiation or other modalities should be discussed through shared decision-making with the physician and patient, contextualizing the maternal and fetal risk from treatments. Healthcare providers should support wide access to reproductive healthcare to allow equitable, evidence-based, patient-centered healthcare.