Bingqin Yang

Dr. Bingqin Yang


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2019 in RSC Advances
Verified
Journal Article
Open access
PDF file
XLXin Leng
Xin Leng
WXWenfeng Xu
Wenfeng Xu
CQChengfang Qiao
Chengfang Qiao
XJXu Jia
Xu Jia
YLYing Long
Ying Long
BYBingqin Yang
Bingqin Yang
Two rhodamine B-based fluorescent probes exhibited remarkable absorbance-on and fluorescence-on responses to Al3+, which can be used for biological imaging.

6 September 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Xin LengXin Leng
Xin Leng
DWDu Wang
Du Wang
ZMZhaoxiang Mi
Zhaoxiang Mi
YZYuchen Zhang
Yuchen Zhang
BYBingqin Yang
Bingqin Yang
FCFulin Chen
Fulin Chen
Copper is an important trace element that plays a crucial role in various physiological and biochemical processes in the body. The level of copper content is significantly related to many diseases, so it is very important to establish effective and sensitive methods for copper detection in vitro and vivo. Copper-selective probes have attracted considerable interest in environmental testing and life-process research, but fewer investigations have focused on the luminescence mechanism and bioimaging for Cu2+ detection. In the current study, a novel fluorescein-based A5 fluorescence probe is synthesized and characterized, and the bioimaging performance of the probe is also tested. We observed that the A5 displayed extraordinary selectivity and sensitivity properties to Cu2+ in contrast to other cations in solution. The reaction between A5 and Cu2+ could accelerate the ring-opening process, resulting in a new band at 525 nm during a larger pH range. A good linearity between the fluorescence intensity and concentrations of Cu2+, ranging from 0.1 to 1.5 equivalent, was observed, and the limit detection of A5 to Cu2+ was 0.11 μM. In addition, the Job’s plot and mass spectrum showed that A5 complexed Cu2+ in a 1:1 manner. The apparent color change in the A5–Cu2+ complex under ultraviolet light at low molar concentrations revealed that A5 is a suitable probe for the detection of Cu2+. The biological test results show that the A5 probe has good biocompatibility and can be used for the cell imaging of Cu2+.

12 May 2014 in RSC Advances
Verified
Journal Article
Closed access
PDF file
MYMeipan Yang
Meipan Yang
WMWenfei Meng
Wenfei Meng
XLXiaojing Liu
Xiaojing Liu
NSNa Su
Na Su
JZJia Zhou
Jia Zhou
BYBingqin Yang
Bingqin Yang
A simple colorimetric and fluorescent chemosensor MP was designed and synthesized and its selective signaling behaviors toward Cu2+ were investigated. Under the optimized conditions, the sensor exhibited specific absorbance-on and fluorescence-on responses to Cu2+ only, which can be tuned for detection with the naked eye. These remarkable properties may allow Cu2+ to be detected directly in the presence of the other examined metal ions. The limit of detection for Cu2+ was up to 0.096 μM. As a fluorescence turn-on sensor, cell experiments showed MP can permeate through cell membranes and react to Cu2+ within living cells.

1 February 2016 in Dyes and Pigments
Verified
Journal Article
Closed access
MZMing Zhang
Ming Zhang
SZShu-Ting Zheng
Shu-Ting Zheng
XLXiao-Jing Liu
Xiao-Jing Liu
YLYing Long
Ying Long
BYBingqin Yang
Bingqin Yang

21 February 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
YBYinjuan Bai
Yinjuan Bai
HZHongpeng Zhang
Hongpeng Zhang
BYBingqin Yang
Bingqin Yang
Xin LengXin Leng
Xin Leng
Copper is a common metallic element that plays an extremely essential role in the physiological activities of living organisms. The slightest change in copper levels in the human body can trigger various diseases. Therefore, it is important to accurately and efficiently monitor copper ion levels in the human body. Recent studies have shown that fluorescent probes have obvious advantages in bioimaging and Cu2+ detection. Therefore, a novel Cu2+ probe (N2) was designed and synthesized from fluorescein, hydrazine hydrate and 5-p-nitrophenylfurfural that is sensitive to and can detect Cu2+ within 100 s. The response mechanism of the N2 probe to Cu2+ was studied by several methods such as Job’s plots and MS analysis, which showed that the Cu2+ and the N2 probe were coordinated in a complexation ratio of 1:1. In addition, compared with other cations investigated in this study, the N2 probe showed excellent selectivity and sensitivity to Cu2+, exhibiting distinct fluorescence absorption at 525 nm. Furthermore, in the equivalent range of 0.1–1.5, there is a good linear relationship between Cu2+ concentration and fluorescence intensity, and the detection limit is 0.10 μM. It is worth mentioning that the reversible reaction between the N2 probe and Cu2+, as well as the good biocompatibility shown by the probe in bioimaging, make it a promising candidate for Cu2+ biosensor applications.

1 October 2015 in Tetrahedron
Verified
Journal Article
Closed access
XLXiao-Jing Liu
Xiao-Jing Liu
MZMing Zhang
Ming Zhang
MYMei-Pan Yang
Mei-Pan Yang
BLBo Li
Bo Li
ZCZhao Cheng
Zhao Cheng
BYBingqin Yang
Bingqin Yang