29 June 2018 in IEEE Transactions on Industry Applications
In recent years, doubly fed induction machine (DFIM) is increasingly being preferred in variable speed pumped storage power plants due to its merits like partial-rated excitation system (cost factor), unity power factor, real and reactive power controls. In large-rated DFIM (250 MW), parallel-connected three-level neutral-point clamped (3L-NPC) back-to-back converter systems are employed as rotor excitation circuit to handle slip power requirements (-10% to +8.33% in Tehri PSPP, India). The power semiconductor device failure in the rotor excitation circuit may cause serious concerns in grid stability and system reliability. To ensure the continuous operation of a generating unit, this paper aims to design a redundant parallel leg configuration with six antiparallel IGBTs for a 3L-NPC back-to-back converter structure to acquire fault tolerant operation under power semiconductor device failure. Furthermore, an efficient active current sharing control strategy with fault tolerant operation is implemented for each converter to obtain better performance of the drive system. In fault tolerant operation, fault identification is computed based on a normalized phase currents average method with less computational effort and timely identification of open switch faults in both grid side converter and rotor side converter. The circuit reconfiguration under postfault operation is performed by antiparallel IGBTs with the help of fault tolerant control scheme. The effectiveness of a designed fault tolerant control scheme is validated through MATLAB/Simulink environment for a 250-MW DFIM system with 25 MW (5-channel) power converters. To ensure the trustworthiness of the simulation, an experimental demonstration is performed through a 2.2-kW DFIM laboratory prototype with a 2-channel 3L-NPC back-to-back converter structure.
20 August 2019 in IEEE Transactions on Industry Applications
Power electronic converter plays a significant role in hydropower generating systems of both fixed and variable speed types. These converters are used in the form of simple rectifier for static dc excitation in fixed speed system and in the form of ac excitation (AC-AC or AC-DC-AC) in variable speed system. Parallel connected multiple three-level neutral-point-clamped (3L-NPC) megawatt back-to-back (BTB) converters have been adopted in recently commissioned variable speed pumped storage units (VSPSU). For such configurations, reliability and efficiency are considered to be prominent. This paper proposes a methodology for effective utilization of parallel-connected BTB power converter for VSPSU of large capacity by performing load dependent activation /deactivation of converters. Vector control strategy for active and reactive power deliveries of VSPSU is formulated. This paper also focusses on losses and thermal behavior of converters at different speeds of generator in accordance with water head variations. The proposed control system is designed in such a way to decrease overall losses in power converter system. The effectiveness of proposed method is explained on a real scale of 250 MW doubly fed induction machine (DFIM) with 5x5 MW power converters using MATLAB/PLECS software and experimental validation is performed through a downscaled 2.2 kW laboratory prototype.
5 October 2017 in IEEE Transactions on Industry Applications
The exploration result of an increase in power electronics converter based variable speed drives for industrial applications reveals the impact of inverter induced bearing current on the prevailing electric machine failure. The bearing current associated with drive systems are concerned about operating frequencies of the solid-state semiconductor switches which may cause the electrostatic charge between stator and rotor which eventually causes damage to windings and bearings. The various techniques comprised in literature to suppress bearing currents are filter design, switching redundancy, common mode circuitry, isolated grounding scheme and grounding the motor shaft. From the literature, the PWM inverter injected common-mode voltage (CMV) is the main source of common-mode current which causes the bearing current. Hence the elimination of CMV paves the way for eliminating bearing current of the machine. This paper presents an innovative solution to suppress bearing currents by aiding a fourth arm circuitry (FAC) to acquire near to zero potential (zero CMV) at machine neutral point. All the proposed circuitry and algorithm are simulated using MATLAB/Simulink and validation is done through a 2.5 kW NPC-MLI laboratory prototype using a Xilinx family SPARTAN-III-3A XC3SD1800A-FG676 DSP-FPGA board.
16 March 2018 in IEEE Transactions on Industry Applications
Doubly fed Induction machine (DFIM) is increasingly being preferred in large rated variable speed pumped storage power plants (PSPP) since it provides better energy efficiency due to optimization of pump/turbine efficiency. Increased efficiency results from the flexibility of operating speed at different hydraulic heads. In doubly fed configuration partial rated power converters feed the rotor circuit. Parallel connected back-to-back voltage source converter (VSC) on rotor side is responsible for starting, braking (dynamic/regenerative) and speed (real power) control of the unit. This paper presents the smooth starting and regenerative braking, and assesses performance under power converter and sensor faults of a 250 MW DFIM pump turbine unit to be commissioned in Tehri PSPP, India. Survivability of the unit during faults is analyzed based on: (i) current, (ii) speed, (iii) dc link voltage. Further, this paper investigates fault tolerant operation of 250 MW DFIM unit at open circuit fault in converters. A 2.2 kW DFIM is tested in the laboratory to corroborate the simulation.
15 November 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In recent years, it has been difficult to achieve power converter redundancy in multi-channel voltage-source inverter (VSI)-fed large rated doubly fed induction machines (DFIMs), and it has not yet been adopted in any commissioned variable-speed pumped storage power plants. Multi-channel VSIs are a fundamental part of DFIMs, and they control the real and reactive power of the machines. This paper presents the fault-tolerant operation of a large rated DFIM hydro-generating unit at open switch faults in back-to-back VSIs. A technique for diagnosing the open-switch faults in grid-side and machine-side converters is proposed. An open-switch fault is detected based on the variation in rotor currents and dc link voltage, which reduces the computational efforts during fault diagnosis. A 250-MW DFIM with five-channel three-level VSIs (each rated at 9 MVA) is simulated in the Matlab/Simulink environment to observe the drive behavior. Finally, a 2.2-kW DFIM is tested in a laboratory environment to verify the simulation results.